If current is over the set value, the relay will be forced to off by the
device, and the state will be reported to the gateway. The over
current alarm function can be disabled, which can be set directly
through the device. Or can be configured through the
Over-current
Alarm
16A by default
ACAlarmsMask and ACCurrentOverload of Electrical Measurement
(0X0B04), for details please refer to the configuration value .
Note: When over current alarm is triggered, the beeper will beep,
to cancel the alarm, just press and hold button
for over 3
seconds or reset power of the device. After cancel manually, the
relay will show heating forbidden icon
other operations are allowed.
within 120 seconds, but
This function is similar to the function of “Internal Over Heat
Protection” described in chapter 4.9. When the control type is
configured as “Room+Floor sensor”, this function will be valid:
The alarm will be triggered when the floor sensor temperature >
Max floor temp, the relay will be forced to off by the device, and
the state will be reported to the gateway. The following indication
figure will prompt on the display.
27°C by default
After the floor sensor temperature < (Max floor temp - Hysteresis),
the alarm will be cancelled automatically and the device will restore
to previous operation mode.
Max floor temp
To cancel the alarm manually, just press and hold button
for
over 3 seconds, but the relay will show heating forbidden icon
within 120 seconds and the alarm will not be triggered again, after
120 seconds expire, the device will restore to previous operation
mode and continue to detect alarm temperature.
This function can be disabled, which can be configured directly
through the device, or can be configured through the attribute Max
floor temp (0x2001) of Thermostat Cluster (0x0201), when this value
is set as 0, this function is disabled.
To prevent the undulation of sensor temperature when the sensor
temperature is approaching the set temperature, which will cause
that the controller may keep switching on/off the relay. Here
hysterersis enables the controller to control the relay only when the
sensor temperature is lower than the set temperature minus the
hysteresis value , this value can be set.
Hysterersis
0.5°C by default
For instance, when hysterersis is set as 0.5 degree, then only when
current sensor temperature < (the set temperature - 0.5 degree),
will the controller heat.
This value can also be configured through the proprietary attribute
Hysterersis (0x100A) of Thermostat Cluster (0x0201).
Set the level of vibration sensor under the buttons or buzzer level.
OFF: vibration or buzzer off Low Level, High Level: low vibration or
Key Vibration
Set
OFF by default
buzzer level, high vibration or buzzer level.
This level can also be configured through the proprietary attribute
ButtonVibrationLevel (0x1001) of Thermostat Cluster (0x0201).
The OLED display brightness when operate the device.
High Level, Mid Level, Low Level.
This brightness can also be configured through the proprietary
attribute OperateDisplayLcdBrightness (0x1000) of Thermostat
Cluster (0x0201).
Display
Brightness Set
Mid Level by default
| General | Details |
|---|---|
| Name | namron 4512737 Touch Zigbee 16A Thermostat Instruction Manual |
| Make | NAMRON |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.47 MB |

namron 1402746 Touch Thermostat Instruction Manual

namron 4512738 Touch Zigbee 16A Thermostat Instruction Manual

namron 16A 2.0 Zigbee Touch Thermostat Instruction Manual

namron Touch Z Wave 16A Thermostat Instruction Manual