Home > NAMRON > namron 4512737 Touch Zigbee 16A Thermostat Instruction Manual

namron 4512737 Touch Zigbee 16A Thermostat Instruction Manual

On the Home Interface, press and hold both  
and  
buttons for  
will flash slowly, the  
Display Auto OFF function can be enabled or disabled, when the  
F
over 10S, during the process, the icon  
Display  
Auto Off  
function is enabled, the icon  
icon will not be displayed.  
will be displayed, otherwise the  
This Display Auto Off can also be configured through the propri-  
etary attribute 0x100B of Thermostat Cluster (0x0201).  
This parameter defines which sensor temperature will be displayed  
on Home page.  
Floor Temp: floor temperature (external sensor) .  
Home Temp: indoor air temperature.  
This status can also be configured through the proprietary attribute  
TemperatureDisplay (0x1008) of Thermostat Cluster (0x0201).  
Display  
Temperature Set  
Home Temp by  
default  
Select  
OTHER SET on Home Interface to enter into OTHER SET  
interface as follow:  
Short press button  
to select the item you would like to modify,  
Other Set  
then short press move up and down buttons to modify value of  
selected item, then short press button to save and quit, short  
F
pressing  
button only quits without saving.  
The displayed temperature may has big tolerance caused by the  
sensor or other factors, so it is necessary to do  
temp compensation to room sensor and floor sensor.  
Compensation range is -5 ~ +5°C, stepping is 0.5°C.  
This value can also be configured through the attribute Local  
TemperatureCalibration (0x0010) of Thermostat Cluster (0x0201),  
and through the proprietary attribute FloorSensorCalibration  
(0x1005) of Thermostat Cluster (0x0201).  
Temperature  
Compensation  
0 by default  
Device state after reset power of the device.  
If set as “last status”, device will go to the status before power failure  
after power on again.  
Re-power  
Status  
last status by  
default  
If set as “default”, device will go to default mode after power on  
again.  
This status can also be configured through the proprietary attribute  
PowerUpStatus (0x1004) of Thermostat Cluster (0x0201).  
To ensure the safety of the device, if the internal temperature of the  
device (not displayed on the interface) is over a certain value during  
heating process, the device will execute a short temporary action to  
Internal Over  
Heat Protection  
turn off the relay, and the icon  
will appear on the interface, after  
the temperature decreases to a certain value, the device will recover  
to work.  
On the Home Interface, press and hold both  
and  
buttons for  
over 10S, the Child Lock can be enabled or disabled, when the  
Child Lock is enabled, the icon will appear at the upper right  
F
C
h
i
l
d
L
o
c
k
corner, otherwise the icon will not appear.  
This Child Lock can also be configured through the attribute  
KeypadLockout (0x0001) of Thermostat Cluster (0x0201).  
GeneralDetails
Namenamron 4512737 Touch Zigbee 16A Thermostat Instruction Manual
MakeNAMRON
LanguageEnglish
FiletypePDF (Download)
File size0.47 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
namron 1402746 Touch Thermostat Instruction Manual
namron 1402746 Touch Thermostat Instruction Manual
namron 4512738 Touch Zigbee 16A Thermostat Instruction Manual
namron 4512738 Touch Zigbee 16A Thermostat Instruction Manual
namron 16A 2.0 Zigbee Touch Thermostat Instruction Manual
namron 16A 2.0 Zigbee Touch Thermostat Instruction Manual
namron Touch Z Wave 16A Thermostat Instruction Manual
namron Touch Z Wave 16A Thermostat Instruction Manual

namron 4512737 Touch Zigbee 16A Thermostat Instruction Manual