namron 4512737 Touch Zigbee 16A Thermostat Instruction Manual
On the Home Interface, press and hold both
and
buttons for
will flash slowly, the
Display Auto OFF function can be enabled or disabled, when the
F
over 10S, during the process, the icon
Display
Auto Off
function is enabled, the icon
icon will not be displayed.
will be displayed, otherwise the
This Display Auto Off can also be configured through the propri-
etary attribute 0x100B of Thermostat Cluster (0x0201).
This parameter defines which sensor temperature will be displayed
on Home page.
Floor Temp: floor temperature (external sensor) .
Home Temp: indoor air temperature.
This status can also be configured through the proprietary attribute
TemperatureDisplay (0x1008) of Thermostat Cluster (0x0201).
Display
Temperature Set
Home Temp by
default
Select
OTHER SET on Home Interface to enter into OTHER SET
interface as follow:
Short press button
to select the item you would like to modify,
Other Set
then short press move up and down buttons to modify value of
selected item, then short press button to save and quit, short
F
pressing
button only quits without saving.
The displayed temperature may has big tolerance caused by the
sensor or other factors, so it is necessary to do
temp compensation to room sensor and floor sensor.
Compensation range is -5 ~ +5°C, stepping is 0.5°C.
This value can also be configured through the attribute Local
TemperatureCalibration (0x0010) of Thermostat Cluster (0x0201),
and through the proprietary attribute FloorSensorCalibration
(0x1005) of Thermostat Cluster (0x0201).
Temperature
Compensation
0 by default
Device state after reset power of the device.
If set as “last status”, device will go to the status before power failure
after power on again.
Re-power
Status
last status by
default
If set as “default”, device will go to default mode after power on
again.
This status can also be configured through the proprietary attribute
PowerUpStatus (0x1004) of Thermostat Cluster (0x0201).
To ensure the safety of the device, if the internal temperature of the
device (not displayed on the interface) is over a certain value during
heating process, the device will execute a short temporary action to
Internal Over
Heat Protection
turn off the relay, and the icon
will appear on the interface, after
the temperature decreases to a certain value, the device will recover
to work.
On the Home Interface, press and hold both
and
buttons for
over 10S, the Child Lock can be enabled or disabled, when the
Child Lock is enabled, the icon will appear at the upper right
F
C
h
i
l
d
L
o
c
k
corner, otherwise the icon will not appear.
This Child Lock can also be configured through the attribute
KeypadLockout (0x0001) of Thermostat Cluster (0x0201).
| General | Details |
|---|---|
| Name | namron 4512737 Touch Zigbee 16A Thermostat Instruction Manual |
| Make | NAMRON |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.47 MB |

namron 1402746 Touch Thermostat Instruction Manual

namron 4512738 Touch Zigbee 16A Thermostat Instruction Manual

namron 16A 2.0 Zigbee Touch Thermostat Instruction Manual

namron Touch Z Wave 16A Thermostat Instruction Manual