Hysterersis  
INT8U  
0x100A  
0x100B  
0x2001  
0x1224  
0x1224  
0x1224  
Hysterersis setting, range is 5-50, unit is 0.1ºC, default value is 5  
reportable  
DisplayAutoOffEnable  
ENUM8  
0, disable Display Auto Off function  
1, enable Display Auto Off function  
reportable  
Max floor temp  
INT8U,  
Floor temperature over heating threshold, range is 0-35, unit is 1ºC,  
0 means this function is disabled, default value is 27.  
reportable  
Away Mode Set:  
ENUM8  
0x2002  
0x1224  
Value=0: not away (default)  
Value=1: away  
reportable  
Command supported:  
Command  
Description  
Setpoint Raise/Lower  
0x0000  
Increase or decrease the set temperature according to current mode, unit is  
0.1ºC  
5.2.5 Simple Meter-0x0702 (Server)  
Attributes supported:  
Type  
Description  
Attribute  
unsigned48 ,  
read-only,  
CurrentSummationDelivered  
0x0000  
Indicates the current amount of electrical energy delivered to the load.  
reportable  
bitmap8 ,  
read-only  
Status  
0x0200  
0x0300  
0x0303  
0x0306  
Flags indicating current device status, always is 0x00  
enum8 ,  
UnitOfMeasure  
read-only  
The unit of metering data, this is always kWh(0x00)  
map8 ,  
SummationFormatting  
read-only  
The decimal point on the left and right sides of the data, this is always 0x00  
bitmap8,  
read-only  
MeteringDeviceType  
Metering data type, this is always Electric Metering (0x00)  
5.2.6 Electrical Measurement-0x0b04(Server)  
Attributes supported:  
Type  
Description  
Attribute  
MeasurementType  
bitmap32 ,  
read-only  
Indicates the physical entities that this devices is able to measure. Supports  
only bit0: Active measurement (AC)  
0x0000  
int16U ,  
RMSVoltage  
read-only,  
reportable  
0x0505  
0x0508  
Single phase valid voltage, unit is V  
int16U ,  
RMSCurrent  
reportable,  
read-only  
Single phase valid current, unit is A  
int16S ,  
ActivePower  
reportable  
read-only  
0x050B  
0x0600  
Single phase valid power, unit is W  
int16U,  
ACVoltageMultiplier  
read-only  
GeneralDetails
Namenamron 4512737 Touch Zigbee 16A Thermostat Instruction Manual
MakeNAMRON
LanguageEnglish
FiletypePDF (Download)
File size0.47 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
namron 1402746 Touch Thermostat Instruction Manual
namron 1402746 Touch Thermostat Instruction Manual
namron 4512738 Touch Zigbee 16A Thermostat Instruction Manual
namron 4512738 Touch Zigbee 16A Thermostat Instruction Manual
namron 16A 2.0 Zigbee Touch Thermostat Instruction Manual
namron 16A 2.0 Zigbee Touch Thermostat Instruction Manual
namron Touch Z Wave 16A Thermostat Instruction Manual
namron Touch Z Wave 16A Thermostat Instruction Manual

namron 4512737 Touch Zigbee 16A Thermostat Instruction Manual