ROOM THERMOSTAT PLACEMENT
ROOM THERMOSTAT WIRING DIAGRAM
ENGLISH
Room Thermostat needs to be placed in the room which is used most
frequently.For instance; living room or lounge.Placing the Room
Thermostat in a spot that have air circulation like entrance of a room
or side of window should be avoided. Also anywhere close to heating
units such as radiator, stove and spots which get direct sun lights
would not be suitable. Room Thermostat needs to be located above
the floor 150 cm height. Few trials may be made to find the most
convenientspot.
HEATING UNIT
DIGITAL ROOM THERMOSTAT
generallife.com.tr
MITRA 110S USER MANUAL
NO COM
GENERAL SPECIFICATIONS
DIGITAL ROOM THERMOSTAT
min. 20 cm
MITRA 110S is a wired room thermostat. The user can adjust the
room temperature with the required temperature and get more
comfortable and economic heating.
WARNING!
Operations inside the boiler or related to the electrical installation
must be carriedout bypersons withprofessional competence.
PreciseTemperatureMeasurement
TPIAlgorithm
Wired Connection
ON/OFFControl
MITRA 110S
USER MANUAL
TPI ROOM THERMOSTAT WORKING LOGIC
MITRA 110S AND EQUIPMENTS
Your Room Thermostat works with the TPI algorithm in the heating
option. Room Thermostats using TPI technology predict when the
temperature of your home will rise above or below the set
temperature and turn the heating unit on and off accordingly. This
ensures that your home stays at the temperature you set without
maximum deviationsup and down.
MITRA 110S
Room Thermostat
Alkaline
Battery
Dowels and
Screws
What is TPI?
TPI technology is designed to ensure that you get the best possible
energy efficiency from your heating system. It measures and applies
the best possible timings to deliver and maintain your home at the set
temperaturelevel.
TECHNICAL DATA
BATTERY PLACEMENT
How does TPIwork?
Dimensions ( H / L / W )
Operating Current
85mm / 125mm / 24mm
3V DC (2 x AAA alkaline battery)
2A/30VDC (Resistive load)
0.5A/125VAC (Resistive load)
0.1oC
Before starting, power off the device connected to the Room
Thermostatand makesurethattheenergy is cutoff.
Thanks to the advanced artificial intelligence technology found in the
software, it adapts to the temperature change of the environment in
which it is located. By creating a general temperature map of your
home, it learns how long it takes to reach the desired room
temperature and how to maintain this temperature. In this way, it
provides minimum energy consumption by calculating how long your
heating unit should workfor.
Relay NO Switching Current
Temperature Measurement
Accuracy
Operating Temperature Range
Battery Life
(5oC) – (35oC)
1 Year (2 x AAA)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
Whatis the difference?
Operating Temperature
Storage Temperature
In non-TPI room thermostats, the heating unit works and stops
continuously until it exceeds the set temperature value. If the set
temperature drops below a certain amount, the heating unit will work
again. This creates greater temperature fluctuations and less energy
control. TPI Room Thermostats, on the other hand, provide higher
savings and comfort compared to On/Off room thermostats with the
advantagesithas.
ROOM THERMOSTAT
As shown in the picture above, press the screwdriver forward from the
space shown, bend the tabs and separate the front cover. Insert 2 new
AAA alkaline batteries in the battery housing with the correct battery
direction. Replace both batteries at the same time. Then align the
front part of your Room Thermostat to the back and squeeze it
towards theback.
TPI ROOM THERMOSTAT WORKING GRAPH
Indicator LED
TEMPERATURE (ºC)
Desired Temperature
TPI Room Thermostat
WARNING!
Adjustment Knob
When the product is not used for a long period (more than 15 days),
remove the batteries. Otherwise, malfunctions that may occur would
be out of warranty.
Pleasethrow yourdead batteriesinto thewastebin for batteries.
23
RoomThermostatIndicator LED Descriptions
If it blinks once
If it blinks twice
The relay contact opens and the heating unit
stops working.
The relay contact closes and the heating unit
starts.
Time
generallife.com.tr
1
2
3
| General | Details |
|---|---|
| Name | GENERAL LIFE MITRA 110S Digital Room Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.03 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE MITRA 110S Digital Room Thermostat User Manual Overview
Summary of Contents
- Page 1: Room thermostat needs to be placed in the room which is used most frequently, such as the living room or lounge. Placing the room thermostat in spots with poor air circulation or near heating units should be avoided. Room thermostat needs to be located at a height of 150 cm above the floor. MITRA 110S is a wired room thermostat that allows users to adjust room temperature for comfort and economic heating. Operations related to the electrical installation must be carried out by persons with professional competence. TPI technology ensures energy efficiency by predicting when the temperature will rise or fall and adjusting the heating unit accordingly. The advanced artificial intelligence in the software adapts to environmental temperature changes to minimize energy consumption. In non-TPI room thermostats, the heating unit operates continuously, leading to greater temperature fluctuations. TPI room thermostats provide higher savings and comfort compared to traditional on/off room thermostats. When not in use for more than 15 days, batteries should be removed to prevent malfunctions.
- Page 2: WARRANTY CERTIFICATE The warranty period starts from the invoice date and is valid for 5 years against manufacturing defects. If the placement of the TPI Room Thermostats is changed, the learning process will restart and should be considered as 7 days. Devices and apparatus are delivered to the customer in working condition. On-site commissioning is subject to a service fee. In case of malfunctioning devices under warranty, testing will determine if the fault is due to customer or manufacturer error. The warranty document must be kept by the customer during the warranty period; if lost, a second document will not be issued. Malfunctions resulting from the use of devices contrary to the user manual are not covered by the warranty. Customers should be aware of any damages and notify the manufacturer from the start of the warranty duration. Battery leakage and errors due to rust or liquid contact in humid environments are not covered by the warranty. Devices and apparatus are out of warranty if damaged by the customer. In case of malfunction within the warranty period, the repair period cannot exceed 20 working days.