ROOM THERMOSTAT PLACEMENT  
ROOM THERMOSTAT WIRING DIAGRAM  
ENGLISH  
Room Thermostat needs to be placed in the room which is used most  
frequently.For instance; living room or lounge.Placing the Room  
Thermostat in a spot that have air circulation like entrance of a room  
or side of window should be avoided. Also anywhere close to heating  
units such as radiator, stove and spots which get direct sun lights  
would not be suitable. Room Thermostat needs to be located above  
the floor 150 cm height. Few trials may be made to find the most  
convenientspot.  
HEATING UNIT  
DIGITAL ROOM THERMOSTAT  
generallife.com.tr  
MITRA 110S USER MANUAL  
NO COM  
GENERAL SPECIFICATIONS  
DIGITAL ROOM THERMOSTAT  
min. 20 cm  
MITRA 110S is a wired room thermostat. The user can adjust the  
room temperature with the required temperature and get more  
comfortable and economic heating.  
WARNING!  
Operations inside the boiler or related to the electrical installation  
must be carriedout bypersons withprofessional competence.  
PreciseTemperatureMeasurement  
TPIAlgorithm  
Wired Connection  
ON/OFFControl  
MITRA 110S  
USER MANUAL  
TPI ROOM THERMOSTAT WORKING LOGIC  
MITRA 110S AND EQUIPMENTS  
Your Room Thermostat works with the TPI algorithm in the heating  
option. Room Thermostats using TPI technology predict when the  
temperature of your home will rise above or below the set  
temperature and turn the heating unit on and off accordingly. This  
ensures that your home stays at the temperature you set without  
maximum deviationsup and down.  
MITRA 110S  
Room Thermostat  
Alkaline  
Battery  
Dowels and  
Screws  
What is TPI?  
TPI technology is designed to ensure that you get the best possible  
energy efficiency from your heating system. It measures and applies  
the best possible timings to deliver and maintain your home at the set  
temperaturelevel.  
TECHNICAL DATA  
BATTERY PLACEMENT  
How does TPIwork?  
Dimensions ( H / L / W )  
Operating Current  
85mm / 125mm / 24mm  
3V DC (2 x AAA alkaline battery)  
2A/30VDC (Resistive load)  
0.5A/125VAC (Resistive load)  
0.1oC  
Before starting, power off the device connected to the Room  
Thermostatand makesurethattheenergy is cutoff.  
Thanks to the advanced artificial intelligence technology found in the  
software, it adapts to the temperature change of the environment in  
which it is located. By creating a general temperature map of your  
home, it learns how long it takes to reach the desired room  
temperature and how to maintain this temperature. In this way, it  
provides minimum energy consumption by calculating how long your  
heating unit should workfor.  
Relay NO Switching Current  
Temperature Measurement  
Accuracy  
Operating Temperature Range  
Battery Life  
(5oC) – (35oC)  
1 Year (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
Whatis the difference?  
Operating Temperature  
Storage Temperature  
In non-TPI room thermostats, the heating unit works and stops  
continuously until it exceeds the set temperature value. If the set  
temperature drops below a certain amount, the heating unit will work  
again. This creates greater temperature fluctuations and less energy  
control. TPI Room Thermostats, on the other hand, provide higher  
savings and comfort compared to On/Off room thermostats with the  
advantagesithas.  
ROOM THERMOSTAT  
As shown in the picture above, press the screwdriver forward from the  
space shown, bend the tabs and separate the front cover. Insert 2 new  
AAA alkaline batteries in the battery housing with the correct battery  
direction. Replace both batteries at the same time. Then align the  
front part of your Room Thermostat to the back and squeeze it  
towards theback.  
TPI ROOM THERMOSTAT WORKING GRAPH  
Indicator LED  
TEMPERATURE (ºC)  
Desired Temperature  
TPI Room Thermostat  
WARNING!  
Adjustment Knob  
When the product is not used for a long period (more than 15 days),  
remove the batteries. Otherwise, malfunctions that may occur would  
be out of warranty.  
Pleasethrow yourdead batteriesinto thewastebin for batteries.  
23  
RoomThermostatIndicator LED Descriptions  
If it blinks once  
If it blinks twice  
The relay contact opens and the heating unit  
stops working.  
The relay contact closes and the heating unit  
starts.  
Time  
generallife.com.tr  
1
2
3
GeneralDetails
NameGENERAL LIFE MITRA 110S Digital Room Thermostat User Manual
MakeGENERAL LIFE
LanguageEnglish
FiletypePDF (Download)
File size2.03 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE MITRA 110S Digital Room Thermostat User Manual
Get the free PDF manual for the GENERAL LIFE MITRA 110S Digital Room Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL LIFE MITRA 110S Digital Room Thermostat User Manual Overview

Summary of Contents

  • Page 1: Room thermostat needs to be placed in the room which is used most frequently, such as the living room or lounge. Placing the room thermostat in spots with poor air circulation or near heating units should be avoided. Room thermostat needs to be located at a height of 150 cm above the floor. MITRA 110S is a wired room thermostat that allows users to adjust room temperature for comfort and economic heating. Operations related to the electrical installation must be carried out by persons with professional competence. TPI technology ensures energy efficiency by predicting when the temperature will rise or fall and adjusting the heating unit accordingly. The advanced artificial intelligence in the software adapts to environmental temperature changes to minimize energy consumption. In non-TPI room thermostats, the heating unit operates continuously, leading to greater temperature fluctuations. TPI room thermostats provide higher savings and comfort compared to traditional on/off room thermostats. When not in use for more than 15 days, batteries should be removed to prevent malfunctions.
  • Page 2: WARRANTY CERTIFICATE The warranty period starts from the invoice date and is valid for 5 years against manufacturing defects. If the placement of the TPI Room Thermostats is changed, the learning process will restart and should be considered as 7 days. Devices and apparatus are delivered to the customer in working condition. On-site commissioning is subject to a service fee. In case of malfunctioning devices under warranty, testing will determine if the fault is due to customer or manufacturer error. The warranty document must be kept by the customer during the warranty period; if lost, a second document will not be issued. Malfunctions resulting from the use of devices contrary to the user manual are not covered by the warranty. Customers should be aware of any damages and notify the manufacturer from the start of the warranty duration. Battery leakage and errors due to rust or liquid contact in humid environments are not covered by the warranty. Devices and apparatus are out of warranty if damaged by the customer. In case of malfunction within the warranty period, the repair period cannot exceed 20 working days.