21. ERROR CODES  
MULTI LEVEL SWITCH DEVICE  
DESCRIPTION  
Err Adding fail. See Chapter 7 “Add/remove”.  
Binary Switch Set.  
Send Binary Switch set commands based on the internal relay state, sends:  
-Binary Switch Set  
Err1 Internal error. Most probably a faulty unit. Contact support.  
Err2 Z-Wave error. Most probably a faulty unit. Contact support.  
Err3 Internal error. Most probably a faulty unit. Contact support.  
Group 2  
Max nodes in group: 10  
Thermostat Setpoint set.  
Sends Thermostat Setpoint set commands based on own setpoint to allow for  
use as master thermostat, sends:  
-Thermostat Setpoint Set  
Group 3  
22.QR-CODE PLACEMENT (DSK)  
Max nodes in group: 10  
The QR-Code is needed when including a device using S2  
security or SmartStart. The DSK can be found in the QR-Code  
and is located;  
Thermostat Mode set.  
Sends Thermostat Mode set commands based on own mode to allow for use as  
master thermostat, sends:  
-Thermostat Mode Set  
Group 4  
On the product.  
Max nodes in group: 10  
In the Quick Guide.  
If the thermostat is to control a relay, an association from  
Group 2 must be created from the thermostat to the relay  
that is to be controlled.  
On the packaging box/gift box.  
23.SECURITY  
S2 security enhances Z-Wave Plus with an additional layer of  
AES 128-bit encryption of the wireless Z-Wave communication  
to prevent hacking and man-in-middle attacks on the home  
network.  
Disclaimer: When using the Heatit Z-Temp3 to control  
multiple relays on a Heatit Z-Water (Art. no. 4512475) or a  
Heatit Z-Water2 (Art. no. 4512495), only use relays 1 through  
7. Do not use relays 8, 9, or 10 for this purpose.  
This device supports S2 and has a Z-Wave DSK QR-Code label  
that may be used when the device is added to the Z-Wave  
home network. The primary controller will ask for a 5-digit  
code. They are the first underlined 5 digits located on the  
QR code sticker. The primary controller will then ask you to  
confirm the rest of the code that is contained in the QR-Code.  
If the thermostat is to control other thermostats as a master  
thermostat, an association from Group 3 and Group 4 must  
be created from the master thermostat to the thermostats to  
be controlled.  
27. CONFIGURATION PARAMETERS  
24.NODE INFORMATION FRAME  
Z-Wave products are supposed to work out of the box after  
inclusion. Some device configuration may, however, alter  
the functionality to better serve user needs or unlock further  
enhanced features. All the parameters below do not feature  
altering capabilities, advanced or read only flags.  
The node information frame is the ”business card” of a Z-Wave  
device. It contains information about the device type and  
its technical features. The add and remove procedure of  
the device is confirmed by sending out a node information  
frame. Besides this, it may be necessary for certain network  
operations to send out a node information frame.  
SHORT  
DESCRIPTION / COMMENT  
DESCRIPTION  
OF VALUE  
NAME  
25.ASSOCIATIONS  
Enabled, buttons on the  
front of the device work.  
(Default)  
Disable buttons, must be en-  
abled through the parameter,  
or turned back on locally by  
holding the center and right  
button for 30 seconds until the  
display shows “UNLK.  
0
Z-Wave devices interact with other Z-Wave devices. The  
relationship between one device controlling another device is  
called an association. In order to control a subordinate device,  
the controlling device needs to maintain a list of devices that  
will receive controlling commands. These lists are called  
”Association Groups”. They are always related to the specific  
event triggered (e.g., sensor reports). In case the event is  
triggered, all devices stored in the respective association group  
will receive a joint wireless command.  
Disable  
buttons  
1
1
0
Disabled, buttons on the  
front of the device are  
disabled.  
1
Minimum  
tempera-  
ture limit  
(ALO)  
Decides the lowest temperatu-  
re allowed by the thermostat  
5°C to 40°C (Default  
is 5°C)  
2
3
2
2
50  
50  
400  
50  
Maximum  
tempera-  
ture limit  
(AHI)  
Decides the highest tempera-  
ture allowed by the thermostat  
5°C to 40°C (Default  
is 40°C)  
400  
400  
-6.0°C to 6.0°C.  
Calibrates the sensor by  
6°C. (Default is 0°C)  
-60  
60  
Calibration  
(CAR)  
Manually calibrate sensor  
A
4
1
0
0
6°C  
NB! To set a negative val-  
ue, use 256 and subtract  
the desired value.  
(195)  
(60)  
25.1 Setting and Removing Associations  
Associations may be assigned and removed via Z-Wave  
commands. Please refer to your primary controller/Z-Wave  
gateway for more information.  
Regulation  
mode  
(REG)  
0
Hysteresis  
Choose between regulation  
modes PWM and Hysteresis.  
5
6
1
1
PWM regulation  
Sends only when  
changed.  
Set the time interval of how  
often the device updates  
Thermostat Setpoint set, Ther-  
mostat Mode set and Binary set  
to associated devices.  
0
Thermostat  
state  
26.ASSOCIATION GROUPS  
2
update  
interval  
150 to 65535 seconds.  
43200 seconds + when  
changed. (Default)  
150  
65535  
30  
MULTI LEVEL SWITCH DEVICE  
DESCRIPTION  
Tempera-  
ture control  
hysteresis  
(HYST)  
Lifeline.  
Choose the hysteresis used  
when regulation mode is set  
to HYST.  
0.3°C to 3.0°C.  
Default is 5 (0.5°C)  
Lifeline Group to be used by primary controller, sends:  
- Thermostat Operating State  
- Thermostat Setpoint Report  
- Thermostat Mode Report  
- Sensor multilevel Report  
- Device Reset Locally  
7
8
9
1
1
1
3
5
0
Display setpoint tempera-  
ture. (Default)  
0
Tempera- Select what is shown on the  
ture display display during Standby state.  
Group 1  
Display measured  
temperature.  
1
- Battery Report  
- Protection Report  
- Configuration Report  
Active  
display  
brightness  
(BR1)  
Configure the brightness of the  
display during active state.  
1
10  
10  
10 to 100% (Default 100%)  
Max nodes in group: 1  
GeneralDetails
NameHEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual
MakeHEATIT
LanguageEnglish
FiletypePDF (Download)
File size0.53 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual
heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual
HEATIT Z-TRM3 Thermostat User Guide
HEATIT Z-TRM3 Thermostat User Guide
Heatit Z-TEMP2 Thermostat Installation Guide
Heatit Z-TEMP2 Thermostat Installation Guide
heatit Z-TRM3 WiFi Thermostat Instruction Manual
heatit Z-TRM3 WiFi Thermostat Instruction Manual
4512673 Heatit ZM Thermostat 16A User Guide
4512673 Heatit ZM Thermostat 16A User Guide
HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide
HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide
HEATIT 54 304 59 DIN Smart Thermostat Installation Guide
HEATIT 54 304 59 DIN Smart Thermostat Installation Guide
HEATIT 54 305 41 WiFi6 Thermostat Installation Guide
HEATIT 54 305 41 WiFi6 Thermostat Installation Guide
HEATIT Z-TEMP3 Thermostat User Guide
HEATIT Z-TEMP3 Thermostat User Guide
heatit ET-7AW Touchscreen Programmable Thermostat User Manual
heatit ET-7AW Touchscreen Programmable Thermostat User Manual

HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual