21. ERROR CODES
MULTI LEVEL SWITCH DEVICE
DESCRIPTION
Err Adding fail. See Chapter 7 “Add/remove”.
Binary Switch Set.
Send Binary Switch set commands based on the internal relay state, sends:
-Binary Switch Set
Err1 Internal error. Most probably a faulty unit. Contact support.
Err2 Z-Wave error. Most probably a faulty unit. Contact support.
Err3 Internal error. Most probably a faulty unit. Contact support.
Group 2
Max nodes in group: 10
Thermostat Setpoint set.
Sends Thermostat Setpoint set commands based on own setpoint to allow for
use as master thermostat, sends:
-Thermostat Setpoint Set
Group 3
22.QR-CODE PLACEMENT (DSK)
Max nodes in group: 10
The QR-Code is needed when including a device using S2
security or SmartStart. The DSK can be found in the QR-Code
and is located;
Thermostat Mode set.
Sends Thermostat Mode set commands based on own mode to allow for use as
master thermostat, sends:
-Thermostat Mode Set
Group 4
•
•
•
On the product.
Max nodes in group: 10
In the Quick Guide.
If the thermostat is to control a relay, an association from
Group 2 must be created from the thermostat to the relay
that is to be controlled.
On the packaging box/gift box.
23.SECURITY
S2 security enhances Z-Wave Plus with an additional layer of
AES 128-bit encryption of the wireless Z-Wave communication
to prevent hacking and man-in-middle attacks on the home
network.
Disclaimer: When using the Heatit Z-Temp3 to control
multiple relays on a Heatit Z-Water (Art. no. 4512475) or a
Heatit Z-Water2 (Art. no. 4512495), only use relays 1 through
7. Do not use relays 8, 9, or 10 for this purpose.
This device supports S2 and has a Z-Wave DSK QR-Code label
that may be used when the device is added to the Z-Wave
home network. The primary controller will ask for a 5-digit
code. They are the first underlined 5 digits located on the
QR code sticker. The primary controller will then ask you to
confirm the rest of the code that is contained in the QR-Code.
If the thermostat is to control other thermostats as a master
thermostat, an association from Group 3 and Group 4 must
be created from the master thermostat to the thermostats to
be controlled.
27. CONFIGURATION PARAMETERS
24.NODE INFORMATION FRAME
Z-Wave products are supposed to work out of the box after
inclusion. Some device configuration may, however, alter
the functionality to better serve user needs or unlock further
enhanced features. All the parameters below do not feature
altering capabilities, advanced or read only flags.
The node information frame is the ”business card” of a Z-Wave
device. It contains information about the device type and
its technical features. The add and remove procedure of
the device is confirmed by sending out a node information
frame. Besides this, it may be necessary for certain network
operations to send out a node information frame.
SHORT
DESCRIPTION / COMMENT
DESCRIPTION
OF VALUE
NAME
25.ASSOCIATIONS
Enabled, buttons on the
front of the device work.
(Default)
Disable buttons, must be en-
abled through the parameter,
or turned back on locally by
holding the center and right
button for 30 seconds until the
display shows “UNLK”.
0
Z-Wave devices interact with other Z-Wave devices. The
relationship between one device controlling another device is
called an association. In order to control a subordinate device,
the controlling device needs to maintain a list of devices that
will receive controlling commands. These lists are called
”Association Groups”. They are always related to the specific
event triggered (e.g., sensor reports). In case the event is
triggered, all devices stored in the respective association group
will receive a joint wireless command.
Disable
buttons
1
1
0
Disabled, buttons on the
front of the device are
disabled.
1
Minimum
tempera-
ture limit
(ALO)
Decides the lowest temperatu-
re allowed by the thermostat
5°C to 40°C (Default
is 5°C)
2
3
2
2
50
50
400
50
Maximum
tempera-
ture limit
(AHI)
Decides the highest tempera-
ture allowed by the thermostat
5°C to 40°C (Default
is 40°C)
400
400
-6.0°C to 6.0°C.
Calibrates the sensor by
6°C. (Default is 0°C)
-60
60
Calibration
(CAR)
Manually calibrate sensor
A
4
1
0
0
6°C
NB! To set a negative val-
ue, use 256 and subtract
the desired value.
(195)
(60)
25.1 Setting and Removing Associations
Associations may be assigned and removed via Z-Wave
commands. Please refer to your primary controller/Z-Wave
gateway for more information.
Regulation
mode
(REG)
0
Hysteresis
Choose between regulation
modes PWM and Hysteresis.
5
6
1
1
PWM regulation
Sends only when
changed.
Set the time interval of how
often the device updates
Thermostat Setpoint set, Ther-
mostat Mode set and Binary set
to associated devices.
0
Thermostat
state
26.ASSOCIATION GROUPS
2
update
interval
150 to 65535 seconds.
43200 seconds + when
changed. (Default)
150
65535
30
MULTI LEVEL SWITCH DEVICE
DESCRIPTION
Tempera-
ture control
hysteresis
(HYST)
Lifeline.
Choose the hysteresis used
when regulation mode is set
to HYST.
0.3°C to 3.0°C.
Default is 5 (0.5°C)
Lifeline Group to be used by primary controller, sends:
- Thermostat Operating State
- Thermostat Setpoint Report
- Thermostat Mode Report
- Sensor multilevel Report
- Device Reset Locally
7
8
9
1
1
1
3
5
0
Display setpoint tempera-
ture. (Default)
0
Tempera- Select what is shown on the
ture display display during Standby state.
Group 1
Display measured
temperature.
1
- Battery Report
- Protection Report
- Configuration Report
Active
display
brightness
(BR1)
Configure the brightness of the
display during active state.
1
10
10
10 to 100% (Default 100%)
Max nodes in group: 1
| General | Details |
|---|---|
| Name | HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual |
| Make | HEATIT |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.53 MB |

heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual

HEATIT Z-TRM3 Thermostat User Guide

Heatit Z-TEMP2 Thermostat Installation Guide

heatit Z-TRM3 WiFi Thermostat Instruction Manual

4512673 Heatit ZM Thermostat 16A User Guide

HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide

HEATIT 54 304 59 DIN Smart Thermostat Installation Guide

HEATIT 54 305 41 WiFi6 Thermostat Installation Guide

HEATIT Z-TEMP3 Thermostat User Guide

heatit ET-7AW Touchscreen Programmable Thermostat User Manual