P03 Hysteresis HOn & HOFF
HOn 0.4°C HOFF 0°C
This menu allows the installer to change the switching differential
of the thermostat when the temperature is rising and falling.
If ‘HYS ON’is set at 0.4˚C and the setpoint is 20˚C, then the
thermostat will switch on when the temperature drops below
19.6˚C.
If ‘HYS OFF’is set at 0.2˚C and the setpoint is 20˚C, then the
thermostat will switch off when the temperature reaches 20.2˚C.
To access this setting, press and hold
seconds.
&
together for 5
‘P01’ will appear on the screen.
Press
until ‘P03’appears on the screen. Press
.
‘HOn’ will appear on the screen and the differential temperature
will begin to flash.