Home > EMOS > EMOS P56201BUF Floor Heating Thermostat User Guide

EMOS P56201BUF Floor Heating Thermostat User Guide

• A3 – Screen child lock  
• Can be set to 0 or 1.  
• 0 = lock off.  
• 1 = lock on.  
• The default value is 0.  
• A4 – Status of the device after reconnecting to power after a power outage  
• Can be set to 0, 1 or 2.  
• 0 = same status as before the outage.  
• 1 = thermostat off.  
• 2 = thermostat on.  
• The default value is 0.  
• A5 – Thermostat screen brightness in standby mode  
• Can be set to 0, 1 or 2.  
• 0 = screen off.  
• 1 = room temperature is slightly illuminated on the screen.  
• 2 = room temperature is strongly illuminated on the screen.  
• The default value is 2.  
• A6 – Calendar Mode selection for Weekly Mode  
• Can be set to 0, 1 or 2.  
• 0 = 5+2 (Mo–Fr + Sa + Su).  
• 1 = 6+1 (Mo–Sa + Su).  
• 2 = 7 days.  
• The default setting is 0.  
• A7 – Minimum temperature setting  
• Can be set to between 1 °C and 10 °C.  
• The default setting is 5 °C.  
• A8 – Maximum temperature setting  
• Can be set to between 20 °C and 70 °C.  
• The default setting is 35 °C.  
• A9 – Low-temperature protection  
• Can be set to between 1 °C and 10 °C or turned off completely.  
• The protection is turned off by setting the value to 10 °C and pressing the arrow. Two dashes will  
appear on the screen.  
• The default setting is 5 °C.  
• AA – High-temperature protection of the external sensor  
• Can be set to between 20 °C and 70 °C or turned off completely.  
• The protection is turned off by setting the value to 20 °C and pressing the arrow. Two dashes will  
appear on the screen.  
• The default setting is 45 °C.  
• AB – Setting the limit of the sensor’s high-temperature protection  
• Can be set to between 1 °C and 9 °C.  
• The default setting is 2 °C.  
• AC – Open Window function (temperature)  
• Can be set to between 10 °C and 20 °C or turned off completely.  
• The function is turned off by setting the value to 10 °C and pressing the  
appear on the screen.  
arrow. Two dashes will  
• The default setting is off.  
• AD – Open window function (interval)  
• Can be set to between 10 and 20 minutes.  
• The default value is 10 minutes.  
• AE – Reset  
• Ao is shown on the screen. To reset to factory settings, hold the  
button for 5 seconds.  
GB | 12  
GeneralDetails
NameEMOS P56201BUF Floor Heating Thermostat User Guide
MakeEMOS
LanguageEnglish
FiletypePDF (Download)
File size0.4 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
emos P56201 Digital Room Thermostat User Manual
emos P56201 Digital Room Thermostat User Manual
EMOS P56201UF Floor Heating Thermostat Instruction Manual
EMOS P56201UF Floor Heating Thermostat Instruction Manual
emos P5604 Thermostat Instruction Manual
emos P5604 Thermostat Instruction Manual
emos P5686 Immersion Thermostat Instructions
emos P5686 Immersion Thermostat Instructions
EMOS P56211 Wireless Thermostat Instruction Manual
EMOS P56211 Wireless Thermostat Instruction Manual
emos P5616OT Wireless Thermostat Instruction Manual
emos P5616OT Wireless Thermostat Instruction Manual
emos P56201UF GoSmart Digital Room Thermostat Instruction Manual
emos P56201UF GoSmart Digital Room Thermostat Instruction Manual
EMOS P5601UF Floor Heating Thermostat User Manual
EMOS P5601UF Floor Heating Thermostat User Manual
emos P56211 Wireless Room Thermostat Instruction Manual
emos P56211 Wireless Room Thermostat Instruction Manual
EMOS P5611OT Wireless Thermostat Instruction Manual
EMOS P5611OT Wireless Thermostat Instruction Manual

EMOS P56201BUF Floor Heating Thermostat User Guide