PURGEAR STC-8080H Digital Thermostat User Guide
STC-8080H Thermostat
Quick Start Guide
(Version 21.08.02GEN)
STC-8080H defrosting thermostat with one sensor and
two output relays to connect and control the
refrigeration and the defrosting unit. There is an editable
delay time for the over-temp alarm function.
1. Wiring Diagram
This unit does not output AC electricity; hence you have
to wire all live and null wires to each port; you may use
the jumper wire conveniently.
1 / 4
| General | Details |
|---|---|
| Name | PURGEAR STC-8080H Digital Thermostat User Guide |
| Make | PURGEAR |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.16 MB |

PURGEAR STC-2304 Digital Thermostat User Guide

PURGEAR STC-100A Digital Thermostat User Guide

PURGEAR STC-1000 Digital Thermostat User Guide
PURGEAR STC-2302 Digital Thermostat User Guide
PURGEAR STC-2303 Digital Thermostat User Guide

PURGEAR STC-8080H Digital Thermostat User Guide Overview
Summary of Contents
- Page 1: STC-8080H thermostat quick start guide. The STC-8080H is a defrosting thermostat with one sensor and two output relays. It connects and controls the refrigeration and defrosting unit. There is an editable delay time for the over-temp alarm function. Wiring diagram is provided. The unit does not output AC electricity. All live and null wires must be wired to each port. Jumper wire can be used conveniently.
- Page 2: Function menu includes various codes for temperature settings and alarms. Temperature for refrigeration starts is indicated by F1. Temperature for refrigeration stops is indicated by F2. Temperature calibration is an important function. Compressor delay time is a configurable setting. Over-temperature triggers an alarm if it exceeds F1. Alarm delay time is also a configurable setting. Defrosting cycle and interval time are specified functions. Defrosting lasting time is a key parameter to set. The aimed temperature range must be defined between F1 and F2.
- Page 3: Key to change the value. Release all keys once it reaches your aim value. Repeat operation from Step 2 / 3 / 4 to adjust other parameters. After configuring all values, press the key to save data and back to normal monitor status. The modified value will be saved automatically and back to normal status if without operation in 30 seconds. Run the forced refrigeration mode. Hold the key to start the defrosting mode. Do it again to stop defrosting. This unit controls the defrosting only by the time, but not by the evaporator temperature.
- Page 4: This is not a step-by-step user manual. It just shows the key points. The new user should read the full-content version user manual. Copyright Haswill-Haswell All rights reserved.