STC-2302 owns 6 touch-sensitive keys, one sensor, and
two output relays to connect and control the refrigerator
and the defrosting unit.
1. Function Menu
Hold the [
] key for 3s to see the Menu List.
Code Function
Defrosting Lasting Time
F1
Defrosting Cycle / Interval Time
Defrosting Cycle / Interval Time Count Mode
F2
F3
The sum working time of the controller
The sum working time of the compressor
0
1
Water dripping Time
F4
F5
Defrosting by, 0is Electric-Thermal,1is Hot Gas
Compressor Startup Protection / Delay time
Alarm Delay time for this unit 1ST-time power on
Over-Temperature Value to Trigger Alarm
Alarm Delay time after time pass F10
Temp. Calibration = Real Temp.-Measured Temp.
F9
F10
F11
F12
F13
1 / 4
| General | Details |
|---|---|
| Name | PURGEAR STC-2302 Digital Thermostat User Guide |
| Make | PURGEAR |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.15 MB |

PURGEAR STC-2304 Digital Thermostat User Guide

PURGEAR STC-8080H Digital Thermostat User Guide

PURGEAR STC-100A Digital Thermostat User Guide

PURGEAR STC-1000 Digital Thermostat User Guide
PURGEAR STC-2303 Digital Thermostat User Guide
PURGEAR STC-2302 Digital Thermostat User Guide Overview
Summary of Contents
- Page 1: STC-2302 thermostat features six touch-sensitive keys, one sensor, and two output relays for controlling the refrigerator and defrosting unit. To access the menu list, hold the [ ] key for three seconds. The menu includes functions such as defrosting lasting time, defrosting cycle/interval time, and compressor startup protection. Additional functions include alarm delay time, over-temperature value to trigger alarm, and temperature calibration.
- Page 2: Wiring diagram. Set the aimed temperature range. The aimed temperature range was defined between the “On Temp.” and the “Off Temp.” Decide the working mode is refrigeration or heating. The aim temperature range will be rewritten to default value once you change F14. Set the temperature for load starts/stops. [On Temp] Key: touch this to check/edit the existing [Temperature for Load Turn On]. [Off Temp] Key: touch this to check/edit the existing [Temperature for Load Turn Off].
- Page 3: Set the defrosting interval time. When F2 = 0, the defrosting function is disabled. When F2 > 0, the defrosting function works. Configure the F5 defrost method. F5 = 0, defrost by electric-thermal. F5 = 1, defrost by hot gas from the compressor reversal rotary. If the keys are locked, hold the [ ] key for 1s to unlock. The icon in the left bottom of the screen will dim when unlocked. It will auto-lock again if there is no operation in 30s. Hold the [ ] key for 10s to restore factory settings.
- Page 4: The screen will display “YES” once it succeeds; Show “ERR” if failed, please power on again before trying. This is not a step-by-step user manual; it just shows the key points. The new user should read the Full-Content Version User Manual. STC-2302 Defrost Thermostat. Copyright Haswill-Haswell All Rights Reserved.