sinope TH1400NP Non Programmable Low Voltage Thermostat Installation Guide
INSTALL YOUR THERMOSTAT
Unlock and lift the
thermostat cover.
If necessary, mark and drill the
1
3
Depending on the heating system,
insert each wire into its terminal
and screw firmly. (See connection
layouts outlined in the following
pages.)
2
appropriate fastening holes, using the
installation template. If needed, use
the wall anchors included.
TH1400NP
Installation Guide
Non-Programmable
Low Voltage Thermostat (24 Vac)
4
Use the provided screws and
wall anchors to fix the
thermostat base on the wall.
6
Power up the thermostat.
5
Replace back and lock the
thermostat cover.
Set
AUXILIARY OUTPUT
WIRING LAYOUT
The thermostat provides an auxiliary heating output that
can act as a second stage of heating when controlling
ambient temperature.
Electric baseboard
Hot water valve
120 V
240 V
347 V
24 V
24 Vac
Valve
normally open
If the room temperature is too far from the setpoint or the
main stage of heating has difficulties raising the
temperature, the auxiliary output activates the secondary
heating source to reach the set temperature.
C
Electric baseboard
R
W1
W2
Both outputs can control different types of heating load and
can be configured in the user settings.
S1
For use in floor or ambient
mode with floor limit.
Floor sensor
S2
Not required for ambient
mode alone.
Electric floor heating with electric
baseboard on the 2nd heating stage
Electric floor heating
Floor sensor
Electric baseboard
CONNECTION OF THE FLOOR SENSOR
(OPTIONAL)
Only for control applications in floor (F) mode or with floor limit.
Increasing or lowering the temperature
To adjust the temperature, press or
. The requested temperature
will blink to confirm the new setpoint.
When installing your floor heating system: add a
second sensor in the floor and store the tip in the
thermostat housing. This additional sensor can be
plugged in and used as a replacement without
haltering your floor heating system.
Set
Sensor
| General | Details |
|---|---|
| Name | sinope TH1400NP Non Programmable Low Voltage Thermostat Installation Guide |
| Make | sinope |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.33 MB |

sinope TH1134ZB-HC Smart Line Voltage Thermostat Owner’s Manual

sinope Smart Low Voltage Thermostat TH1400WF Installation Guide

sinope Smart Floor Heating Thermostat TH1310WF Installation Guide

sinope TH1124NP Non Programmable Thermostat for Electric Heating Owner’s Manual

sinope TH1300ZB-C4 3600W Smart Floor Heating Thermostat Installation Guide

sinope TH1134ZB Smart Line Voltage Thermostat Installation Guide

sinope TH1500ZB Smart Double Pole Thermostat Installation Guide

sinope TH1500WF Smart Double Pole Thermostat Installation Guide
sinope TH1400NP Non Programmable Low Voltage Thermostat Installation Guide Overview
Summary of Contents
- Page 1: Install your thermostat by unlocking and lifting the thermostat cover. Mark and drill the appropriate fastening holes using the installation template. Insert each wire into its terminal and screw firmly, following the connection layouts. Use the provided screws and wall anchors to fix the thermostat base on the wall. Power up the thermostat and replace back and lock the thermostat cover. The thermostat provides an auxiliary heating output that can act as a second stage of heating. The auxiliary output activates the secondary heating source if the room temperature is too far from the setpoint. Both outputs can control different types of heating load and can be configured in the user settings. For control applications in floor mode or with floor limit, a floor sensor can be connected. To adjust the temperature, press the appropriate buttons, and the requested temperature will blink to confirm the new setpoint.
- Page 2: Parameters that can be controlled from the device include cycle length, temperature format, control mode, and backlight control. The thermostat features two temperature control modes: A mode for ambient temperature regulation and F mode for floor temperature regulation. To access the menu, lower the setpoint to its minimum and hold the button for 10 seconds. The maximum floor temperature limit is only visible in A mode, while the minimum floor temperature limit is also only visible in A mode. The circulator pump's anti-seizure feature activates the main output during 1 minute every 24 hours to prevent the pump from seizing. Operating voltage is 24 Vac with a maximum load of 1 Amp. The troubleshooting guide includes information on the E1F code, which indicates that the thermostat is in Floor mode without a connected sensor. The setpoint range is from 5 °C to 36 °C (41 °F to 97 °F), and the display range is from 0 °C to 70 °C (32 °F to 99 °F). The warranty covers defects in material and workmanship for a 3-year period under normal use. The product is compatible with various heating systems, including baseboard heaters, fan-forced convectors, and hydronic heating systems.