INSTALL YOUR THERMOSTAT  
Unlock and lift the  
thermostat cover.  
If necessary, mark and drill the  
1
3
Depending on the heating system,  
insert each wire into its terminal  
and screw firmly. (See connection  
layouts outlined in the following  
pages.)  
2
appropriate fastening holes, using the  
installation template. If needed, use  
the wall anchors included.  
TH1400NP  
Installation Guide  
Non-Programmable  
Low Voltage Thermostat (24 Vac)  
4
Use the provided screws and  
wall anchors to fix the  
thermostat base on the wall.  
6
Power up the thermostat.  
5
Replace back and lock the  
thermostat cover.  
Set  
AUXILIARY OUTPUT  
WIRING LAYOUT  
The thermostat provides an auxiliary heating output that  
can act as a second stage of heating when controlling  
ambient temperature.  
Electric baseboard  
Hot water valve  
120 V  
240 V  
347 V  
24 V  
24 Vac  
Valve  
normally open  
If the room temperature is too far from the setpoint or the  
main stage of heating has difficulties raising the  
temperature, the auxiliary output activates the secondary  
heating source to reach the set temperature.  
C
Electric baseboard  
R
W1  
W2  
Both outputs can control different types of heating load and  
can be configured in the user settings.  
S1  
For use in floor or ambient  
mode with floor limit.  
Floor sensor  
S2  
Not required for ambient  
mode alone.  
Electric floor heating with electric  
baseboard on the 2nd heating stage  
Electric floor heating  
Floor sensor  
Electric baseboard  
CONNECTION OF THE FLOOR SENSOR  
(OPTIONAL)  
Only for control applications in floor (F) mode or with floor limit.  
Increasing or lowering the temperature  
To adjust the temperature, press or  
. The requested temperature  
will blink to confirm the new setpoint.  
When installing your floor heating system: add a  
second sensor in the floor and store the tip in the  
thermostat housing. This additional sensor can be  
plugged in and used as a replacement without  
haltering your floor heating system.  
Set  
Sensor  
GeneralDetails
Namesinope TH1400NP Non Programmable Low Voltage Thermostat Installation Guide
Makesinope
LanguageEnglish
FiletypePDF (Download)
File size0.33 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
sinope TH1134ZB-HC Smart Line Voltage Thermostat Owner’s Manual
sinope TH1134ZB-HC Smart Line Voltage Thermostat Owner’s Manual
sinope Smart Low Voltage Thermostat TH1400WF Installation Guide
sinope Smart Low Voltage Thermostat TH1400WF Installation Guide
sinope Smart Floor Heating Thermostat TH1310WF Installation Guide
sinope Smart Floor Heating Thermostat TH1310WF Installation Guide
sinope TH1124NP Non Programmable Thermostat for Electric Heating Owner’s Manual
sinope TH1124NP Non Programmable Thermostat for Electric Heating Owner’s Manual
sinope TH1300ZB-C4 3600W Smart Floor Heating Thermostat Installation Guide
sinope TH1300ZB-C4 3600W Smart Floor Heating Thermostat Installation Guide
sinope TH1134ZB Smart Line Voltage Thermostat Installation Guide
sinope TH1134ZB Smart Line Voltage Thermostat Installation Guide
sinope TH1500ZB Smart Double Pole Thermostat Installation Guide
sinope TH1500ZB Smart Double Pole Thermostat Installation Guide
sinope TH1500WF Smart Double Pole Thermostat Installation Guide
sinope TH1500WF Smart Double Pole Thermostat Installation Guide

Get the free PDF manual for the sinope TH1400NP Non Programmable Low Voltage Thermostat Installation Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

sinope TH1400NP Non Programmable Low Voltage Thermostat Installation Guide Overview

Summary of Contents

  • Page 1: Install your thermostat by unlocking and lifting the thermostat cover. Mark and drill the appropriate fastening holes using the installation template. Insert each wire into its terminal and screw firmly, following the connection layouts. Use the provided screws and wall anchors to fix the thermostat base on the wall. Power up the thermostat and replace back and lock the thermostat cover. The thermostat provides an auxiliary heating output that can act as a second stage of heating. The auxiliary output activates the secondary heating source if the room temperature is too far from the setpoint. Both outputs can control different types of heating load and can be configured in the user settings. For control applications in floor mode or with floor limit, a floor sensor can be connected. To adjust the temperature, press the appropriate buttons, and the requested temperature will blink to confirm the new setpoint.
  • Page 2: Parameters that can be controlled from the device include cycle length, temperature format, control mode, and backlight control. The thermostat features two temperature control modes: A mode for ambient temperature regulation and F mode for floor temperature regulation. To access the menu, lower the setpoint to its minimum and hold the button for 10 seconds. The maximum floor temperature limit is only visible in A mode, while the minimum floor temperature limit is also only visible in A mode. The circulator pump's anti-seizure feature activates the main output during 1 minute every 24 hours to prevent the pump from seizing. Operating voltage is 24 Vac with a maximum load of 1 Amp. The troubleshooting guide includes information on the E1F code, which indicates that the thermostat is in Floor mode without a connected sensor. The setpoint range is from 5 °C to 36 °C (41 °F to 97 °F), and the display range is from 0 °C to 70 °C (32 °F to 99 °F). The warranty covers defects in material and workmanship for a 3-year period under normal use. The product is compatible with various heating systems, including baseboard heaters, fan-forced convectors, and hydronic heating systems.