EMOS P56201BUF Floor Heating Thermostat User Guide
Advanced Settings
Temperature Calibration
• The temperature sensor in the thermostat is calibrated from production, but additional calibration can
be done to optimise the thermostat further, for instance by comparing the measured room temperature
with a reference thermometer.
• Example: The thermostat shows room temperature of 22 °C; setting calibration to +1 °C will cause the
thermostat to display 23 °C instead.
• Calibration can be set in EMOS GoSmart in a range of -9 °C to 9 °C with 1 °C resolution.
Temperature Differential
• The temperature differential (hysteresis) is the difference in temperature required for switching the
system on and off.
• Example: If you set the temperature in the heating system to 20 °C and differential to 2 °C, the thermostat
activates heating as soon as room temperature drops to 18 °C and switches heating off when temperature
reaches 22 °C.
• The temperature differential of the internal sensor can be set to between 0.5 °C and 2.5 °C.
• The temperature differential of the floor sensor can be set to between 1 °C and 9 °C (EMOS GoSmart app).
Temperature Limits for Manual Thermostat Settings
• Maximum temperature setting limit – specifies the maximum temperature that can be set on the ther-
mostat (20 °C to 70 °C, 1 °C resolution).
• Minimum temperature setting limit – specifies the minimum temperature that can be set on the thermostat
(1 °C to 20 °C, 1 °C resolution).
Temperature Protection
• High-temperature protection – specifies the maximum temperature the thermostat heats the system up to.
• Example: When temperature protection for the sensor is set to 45 °C and the limit to 2 °C, the thermostat
relay switches off if temperature exceeds 45 °C and turns on again if temperature drops to 43 °C.
• Low-temperature protection – specifies the lowest possible room temperature. If the temperature drops
below the set value, the thermostat will start automatically heating up the room. Can be set to between
1 °C and 10 °C.
Status of the Device after Reconnecting to Power after a Power Outage
• The same as before turning off – the thermostat returns to the state it was in before the power outage.
• Off – the thermostat stays off after reconnecting.
• On – the thermostat turns on after reconnecting.
Active Temperature Sensor
• The setting defines which sensor is detecting temperature – either the internal sensor, floor sensor or both.
Child Lock
• The child lock is activated/deactivated in the settings of the EMOS GoSmart app or by holding the
button for 3 seconds.
• If the lock is active, a lock icon will be displayed on the thermostat’s screen or the thermostat’s main
page in EMOS GoSmart.
Thermostat Screen Brightness in Standby Mode
• Specifies screen brightness after 10 seconds of inactivity.
• Can only be adjusted in the settings on the thermostat’s screen.
• 0 = screen off
• 1 = room temperature is slightly illuminated on the screen
• 2 = room temperature is strongly illuminated on the screen
Open Window Function
• If the thermostat detects a sudden drop in temperature (e.g. when the window or door is open), it stops
heating the room.
• The thermostat will resume heating the room after the set time period elapses or after you close the
window.
• The function can only be set/turned off in the settings on the thermostat’s screen.
GB | 10
| General | Details |
|---|---|
| Name | EMOS P56201BUF Floor Heating Thermostat User Guide |
| Make | EMOS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.4 MB |

emos P56201 Digital Room Thermostat User Manual

EMOS P56201UF Floor Heating Thermostat Instruction Manual

emos P5604 Thermostat Instruction Manual

emos P5686 Immersion Thermostat Instructions

EMOS P56211 Wireless Thermostat Instruction Manual

emos P5616OT Wireless Thermostat Instruction Manual

emos P56201UF GoSmart Digital Room Thermostat Instruction Manual

EMOS P5601UF Floor Heating Thermostat User Manual

emos P5684 Capillary Sensor Thermostat User Manual

emos P56211 Wireless Room Thermostat Instruction Manual