EcoNet RETST800SYS Smart Thermostat User Guide

Thermostat Settings  
Installer Settings  
Go to Menu > Settings > Installer (tap and hold) > Thermostat.  
Thermostat  
Furnace  
AC/HP  
Air Handler  
Defaults  
Warning! These settings are to be used  
by a qualified HVACcontractor ONLY  
BACK  
Thermostat Settings  
Thermostat Brand – The EcoNet Smart Thermostat will automatically  
populate when the system starts up by reading the equipment’s model data card.  
Thermostat Brand  
Rheem  
Aux Heat Hold Off Time  
Filter Check Hour  
Anticipator  
Auto  
9 am  
0
Aux. Heat Hold Off Time – This setting is designed to keep the auxiliary heat  
off for a duration of time determined by the user. The time periods are:  
BACK  
• Auto: The thermostat will energize Aux Heat once the temperature has  
reached 1 full degree beyond the heat set point. Also if the heating  
system is not maintaining the set point using the heat pump alone.  
• 1-60 min: The number of minutes the system will keep the Aux Heat  
from coming on even when the space temperature goes beyond 1 degree.  
Filter Check Hour – The time of day when the EcoNet Smart Thermostat will  
check the air filter status.  
Anticipator – Gives the user the ability to accurately control the system  
from overshooting in the Heating and the lag of delivering conditioned air in  
the cooling mode. When set to 0 the system will use the factory default and  
recommended rate of equipment cycling to maintain comfort. Increasing  
the number will slow down the system, causing longer cycles. Reducing the  
number will make the system react quicker, shortening the equipment cycle.  
The higher the negative  
number the faster the system  
will cycle off, increasing the  
number of times the system  
cycles off in an hour.  
The higher the positive  
number the longer the system  
will stay cycled on, lowering  
the number of times the  
system cycles off in an hour.  
-5  
-4  
-3  
-2  
-1  
1
2
3
4
5
0
Factory set default  
and  
recommended  
rate of equipment  
cycling.  
Air Handler Settings  
Installer Settings  
Go to Menu > Settings > Installer (tap and hold) > Air Handler.  
Thermostat  
Furnace  
AC/HP  
Air Handler  
Defaults  
Warning! These settings are to be used  
by a qualified HVACcontractor ONLY  
BACK  
Air Hander Settings  
Electric Heater Size – If electric strip heaters are installed in the air handler  
Electric Heater Size  
None  
you will need to select the appropriate size.  
EXV Superheat Offset  
0° F  
O Input Fan Control  
Off  
Off  
Off  
Electric Heat Airflow Select – Four choices available. Refer to air handler  
installation instructions for air flow settings.  
Aux #1 Config  
Aux #2 Config  
Filter Type  
N.O.  
N.O.  
Media  
BACK  
See pages 28-29 for the G Input and AUX Input details. These settings are the  
same for both furnace and air handler.  
> Return to Table of Contents  
EcoNet® Smart Thermostat User Guide 31  
GeneralDetails
NameEcoNet RETST800SYS Smart Thermostat User Guide
MakeEcoNet
LanguageEnglish
FiletypePDF (Download)
File size6.45 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
EcoNet UETST800SYS Smart Thermostat User Guide
EcoNet UETST800SYS Smart Thermostat User Guide

EcoNet RETST800SYS Smart Thermostat User Guide