EcoNet RETST800SYS Smart Thermostat User Guide

Wiring Remote Temperature Sensor  
The EcoNet Smart Thermostat is optimized to work with the Aprilaire 8051 Temperature Sensor (10K thermistor).  
Use the S1 and S2 terminals on the wall plate terminal block. Only one remote temperature sensor can  
be supported.  
Go to Menu > Settings > Basic > Room Sensor Selection. You can choose  
Basic Settings  
Set Point Deadband  
Temperature Offset  
2º F  
to have the system function based on the temperatures measured by the  
internal sensor of the thermostat, the remote sensor or the average between  
the two sensors.  
0.0º F  
Relative Humidity Offset  
0.0 %  
Room Sensor Selection  
Internal  
Proximity Sensing?  
No  
Smooth Arrival Enabled?  
No  
BACK  
MORE
The following table shows the correct resistance at various ambient temperatures without the sensor wires  
attached to the thermostat.  
Temperature (°F)  
Resistance (k)  
30  
40  
50  
60  
70  
34.6  
26.1  
19.9  
15.3  
11.9  
9.4  
80  
90  
100  
7.4  
5.9  
> Return to Table of Contents  
EcoNet® Smart Thermostat User Guide 27  