EcoNet RETST800SYS Smart Thermostat User Guide
Settings (con’t)
Basic Settings
More >
Set Point Deadband
Temperature Offset
2º F
Set Point Deadband – This is the minimum difference between heating and
cooling set points in Auto mode. The default is 2 degrees. This setting is
configurable between 0 and 6 degrees. A 0 degree deadband means your
system will switch between heating and cooling to maintain the specified set
point. The smaller the deadband setting the more frequently your system will
switch between heating and cooling.
0.0º F
Relative Humidity Offset
0.0 %
Room Sensor Selection
Internal
Proximity Sensing?
Yes
Yes
Smooth Arrival Enabled?
BACK
MORE
Temperature Offset – This is an offset applied to the displayed room
temperature. A negative offset will cause the displayed indoor temperature to
be less than the sensed temperature. A positive offset will cause the displayed
temperature to be higher than sensed temperature.
Relative Humidity Offset – This is an offset applied to the indoor relative
humidity. A negative offset will cause the displayed relative humidity to be less
than the sensed relative humidity. A positive offset will cause the displayed
relative humidity to be higher than sensed relative humidity.
Note: You should allow the thermostat to calibrate in the conditioned space for 30 minutes before
adjusting offsets.
Room Sensor Selection – You can wire a remote 10K temperature sensor* to
the EcoNet Smart Thermostat. If a remote temperature sensor is connected,
you can choose to use the remote sensor, internal sensor on the Smart
Thermostat or an average between the two for current indoor temperature.
*Optimized for use with an Aprilaire 8051 indoor temperature sensor.
Basic Settings
Proximity Sensing** – Selecting ‘No’ will disable the motion sensor. To
activate the thermostat, you will need to tap the screen.
Set Point Deadband
Temperature Offset
2º F
0.0º F
**Motion Sensor may not be available on all units.
Relative Humidity Offset
0.0 %
Room Sensor Selection
Internal
Smooth Arrival – The thermostat will start recovery at the optimum time
to ensure the set point is reached at the scheduled time. If a setback in
temperature is scheduled, for either cooling or heating, the set temperature
is ramped to the next scheduled set temperature 60 minutes before the next
time period.
Proximity Sensing?
Yes
Yes
Smooth Arrival Enabled?
BACK
MORE
Basic Settings
Backlight Enabled?
Yes
Backlight Enabled – When the thermostat is not being used it will enter
standby mode. The default screen brightness in standby is 1%. You can turn
off the Backlight when in standby by selecting “No.”
BACK
Settings
Time & Date (Menu > Settings > Time)
Set the current time and date. Your schedule times, vacation events and
weather forecast will be based off the time entered on this screen. It is
important to ensure the correct date and time are programmed before
setting your schedule.
Basic
Time
Humidity
Fan
Away
Vacation
BACK
Installer
Time and Date
DST – At the bottom of this screen you can elect to enable or disable
daylight savings time.
38 pm
2
:
Jan
29
2018
Accept
D.S.T. Yes
BACK
> Return to Table of Contents
EcoNet® Smart Thermostat User Guide 13