EcoNet RETST800SYS Smart Thermostat User Guide

Settings (con’t)  
Basic Settings  
More >  
Set Point Deadband  
Temperature Offset  
2º F  
Set Point Deadband – This is the minimum difference between heating and  
cooling set points in Auto mode. The default is 2 degrees. This setting is  
configurable between 0 and 6 degrees. A 0 degree deadband means your  
system will switch between heating and cooling to maintain the specified set  
point. The smaller the deadband setting the more frequently your system will  
switch between heating and cooling.  
0.0º F  
Relative Humidity Offset  
0.0 %  
Room Sensor Selection  
Internal  
Proximity Sensing?  
Yes  
Yes  
Smooth Arrival Enabled?  
BACK  
MORE
Temperature Offset – This is an offset applied to the displayed room  
temperature. A negative offset will cause the displayed indoor temperature to  
be less than the sensed temperature. A positive offset will cause the displayed  
temperature to be higher than sensed temperature.  
Relative Humidity Offset – This is an offset applied to the indoor relative  
humidity. A negative offset will cause the displayed relative humidity to be less  
than the sensed relative humidity. A positive offset will cause the displayed  
relative humidity to be higher than sensed relative humidity.  
Note: You should allow the thermostat to calibrate in the conditioned space for 30 minutes before  
adjusting offsets.  
Room Sensor Selection – You can wire a remote 10K temperature sensor* to  
the EcoNet Smart Thermostat. If a remote temperature sensor is connected,  
you can choose to use the remote sensor, internal sensor on the Smart  
Thermostat or an average between the two for current indoor temperature.  
*Optimized for use with an Aprilaire 8051 indoor temperature sensor.  
Basic Settings  
Proximity Sensing** – Selecting ‘No’ will disable the motion sensor. To  
activate the thermostat, you will need to tap the screen.  
Set Point Deadband  
Temperature Offset  
2º F  
0.0º F  
**Motion Sensor may not be available on all units.  
Relative Humidity Offset  
0.0 %  
Room Sensor Selection  
Internal  
Smooth Arrival – The thermostat will start recovery at the optimum time  
to ensure the set point is reached at the scheduled time. If a setback in  
temperature is scheduled, for either cooling or heating, the set temperature  
is ramped to the next scheduled set temperature 60 minutes before the next  
time period.  
Proximity Sensing?  
Yes  
Yes  
Smooth Arrival Enabled?  
BACK  
MORE
Basic Settings  
Backlight Enabled?  
Yes  
Backlight Enabled – When the thermostat is not being used it will enter  
standby mode. The default screen brightness in standby is 1%. You can turn  
off the Backlight when in standby by selecting “No.”  
BACK  
Settings  
Time & Date (Menu > Settings > Time)  
Set the current time and date. Your schedule times, vacation events and  
weather forecast will be based off the time entered on this screen. It is  
important to ensure the correct date and time are programmed before  
setting your schedule.  
Basic  
Time  
Humidity  
Fan  
Away  
Vacation  
BACK  
Installer  
Time and Date  
DST – At the bottom of this screen you can elect to enable or disable  
daylight savings time.  
38 pm  
2
:
Jan  
29  
2018  
Accept  
D.S.T. Yes  
BACK  
> Return to Table of Contents  
EcoNet® Smart Thermostat User Guide 13  
GeneralDetails
NameEcoNet RETST800SYS Smart Thermostat User Guide
MakeEcoNet
LanguageEnglish
FiletypePDF (Download)
File size6.45 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
EcoNet UETST800SYS Smart Thermostat User Guide
EcoNet UETST800SYS Smart Thermostat User Guide

EcoNet RETST800SYS Smart Thermostat User Guide