How do I connect a ventilator (HRV or ERV) to an EcoNet HVAC system?  
One must use the ventilator’s wall control in the traditional manner, except only wire the ventilator control to  
the G terminal of the furnace (do not wire to the Y or W terminals). In the EcoNet furnace setup menu, change  
the G Input Fan Control to a fan speed that is desirable to run with the ventilator. The EcoNet system monitors  
the furnace G terminal, and will turn on the fan when requested by the G terminal signal (when it is not heating  
or cooling).  