Home > EcoNet > EcoNet RETST800SYS Smart Thermostat User Guide

EcoNet RETST800SYS Smart Thermostat User Guide

Service  
Menu  
Selecting Menu > Service from the home screen will display current alarms,  
alarm history, service alerts, contact info and equipment info.  
Settings  
Schedule  
Status  
Service  
Water Heating  
BACK  
Service  
Current – Shows any alerts or alarms that are currently active. When an  
equipment alert/alarm is present, an alert/alarm icon will appear in the upper  
right corner of the home screen, and the alarm beep will sound if enabled.  
Select the alert/alarm icon on the home screen to quickly view the alert/alarm  
and a brief description.  
Current  
History  
Alerts  
Equip.  
Support  
BACK  
Service  
History – Shows a list of the past eight alerts/alarms with the time and  
date stamp.  
Current  
History  
Alerts  
Equip.  
Support  
BACK  
Alarm History  
14:47:01 01/29/18  
A021_A Restricted airflow detected. Possible frozen coil  
20:33:40 02/02/18  
A929_O 240V Missing or Inverter Comm Failure 16  
Clear History  
BACK  
Service  
Alerts – Allows you to set time-based maintenance reminders for a service  
call, humidifier pad and UV light replacement. Toggle to ‘No’ to disable service  
reminders. You can also change the time for the alert. If a Service Alert is  
present, the item will have a “reset” label next to it. Tapping “reset” will clear  
the alert and start the maintenance timer over.  
Current  
History  
Alerts  
Equip.  
Support  
BACK  
Service Call – Generates an alert telling the homeowner that regularly  
scheduled maintenance is due.  
Service Alerts  
Air Filter – If a common ‘media’ filter is used, our EcoNet system is smart  
enough to detect and alert you when it is time to replace the air filter. You  
can easily see how much life your air filter has left by checking the percent  
used. If no alert is sent in a 12 month period the system will automatically  
remind you it is time to replace the air filter.  
Service Call  
Air Filter  
Yes  
12 months 12 left  
Yes  
55% used  
Humidifier Pad  
Yes  
12 months 12 left  
Yes  
12 months  
UV Lights  
BACK  
12 left  
If an Electronic Air Cleaner (EAC) filter is used the reminder will revert back  
to a time based reminder. The default is set to 6 months.  
Humidifier Pad – Reminds you to clean or replace the humidifier pad  
based on your chosen interval.  
UV Lights – Generates an alert indicating that it is time to clean or replace  
the lamp if the HVAC system uses a UV lamp for air purification.  
> Return to Table of Contents  
EcoNet® Smart Thermostat User Guide 19  
GeneralDetails
NameEcoNet RETST800SYS Smart Thermostat User Guide
MakeEcoNet
LanguageEnglish
FiletypePDF (Download)
File size6.45 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
EcoNet UETST800SYS Smart Thermostat User Guide
EcoNet UETST800SYS Smart Thermostat User Guide

EcoNet RETST800SYS Smart Thermostat User Guide