Danfoss RA 2000 Radiator Thermostat Installation Guide
Installation Instructions
Radiator thermostat RA 2000, universal model
Installation, temperature setting, limitation and blocking, theft protection
Installation
The remote sensor must not
be in a drafty location or be
covered. Do not install above a
heat source. Attach the sensor
To remove the thermostat turn bracket to the desired location.
the base counter-clockwise.
This will also reset the the
snap-action mechanism when
an audible "click" is heard.
Pull out the required length of
capillary tube and secure to
the sensor as shown. Push the
sensor onto the base.
Remove the valve cover.
Check that the thermostat is
set at the factory setting of 5.
Push the thermostat firmly
onto the valve until an au-
dible "click" is heard.
Mounting thermostat with built-in sensor
Mounting thermostat with remote sensor
Temperature setting
guidelines only. The actual room tem-
perature will depend on structural fac-
tors affecting the thermostats, location,
etc.
The required room temperature is
obtained by turning the thermostat
knob. The numbers on the dial cor-
respond to the approximate tem-
peratures of the scale.
45 49
79,5 14
57
17
63
68
73
23 26
79 82°F
28°C
20
l
1
2
•
•
3
•
•
4
5
l
= Frost protection setting
The temperatures indicated are
Limiting and blocking the setting range
Upper limit setting (max. setting)
Lower limit setting (min. setting)
Locking setting
Example: Required max. value = “4”
Set thermostat at “4”
-
Example: Required locked value = “3”
- Set thermostat at “3”
Example: Required min. value = “2”
- Set thermostat at “2”
- Remove a pin from the bottom of the
thermostat with a screwdriver and
mount it under the diamond mark on
the knob (between setting positons 1
and 2).
- Remove both pins from the the ther-
mostat.
- Place one pin under the diamond mark
and the othger pin under the triangle
mark.
- Remove a pin from the bottom of the
thermostat with a screwdriver and
mount it under the triangle mark on
the knob (between setting positons
2 and 3).
Theft protection
Remove the cover and install the theft
protection button, code 013G5245
without pushing it all the way in.
Once the thermostat is mounted on
the valve, push in the theft protection
device. The thermostat cannot be
removed.
To remove the theft protection use
screwdriver 013G1236 and screw into
the hole (1). Pulled out until the stop is
reached (2).
DKCD
VI.51.T6.12 1/2003
| General | Details |
|---|---|
| Name | Danfoss RA 2000 Radiator Thermostat Installation Guide |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.37 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide

Danfoss RA 2000 Radiator Thermostat Installation Guide Overview
Summary of Contents
- Page 1: Installation instructions for radiator thermostat RA 2000, universal model include temperature setting, limitation and blocking, and theft protection. The remote sensor must not be in a drafty location or covered, and should not be installed above a heat source. To remove the thermostat, turn the bracket counter-clockwise to reset the snap-action mechanism. Check that the thermostat is set at the factory setting of 5 before mounting. The required room temperature is obtained by turning the thermostat knob, which corresponds to approximate temperatures on the scale. Frost protection setting is indicated on the thermostat. Limiting and blocking the setting range includes upper and lower limit settings. Locking settings can be achieved by removing pins and placing them under specific marks on the knob. The theft protection button must be installed without pushing it all the way in, and the thermostat cannot be removed once the device is engaged. To remove the theft protection, use a screwdriver to pull out the device until the stop is reached.
- Page 2: Installation instructions for the radiator thermostat RA 2000, tamper-proof model include temperature setting, limiting and blocking, and theft protection. The remote sensor should not be in a drafty location or covered and must not be installed above a heat source. The thermostat is set at the factory setting of 5 and must be pushed firmly onto the valve until an audible click is heard. Temperature setting guidelines indicate that the actual room temperature will depend on various structural factors. The required room temperature is obtained by turning the thermostat knob, with numbers on the dial corresponding to approximate temperatures. Limiting and blocking the setting range includes upper and lower limit settings, as well as locking settings. Theft protection devices and limit pins are available as accessories. The setting window can be covered using scale covers that are available as an accessory. The theft protection device should be pushed into the hexagonal hole of the allen screw.