Home > EPH CONTROLS > EPH CONTROLS RFRB RF Room Thermostat Instruction Manual
EPH CONTROLS RFRB RF Room Thermostat Instruction Manual
Page 1 of 2
Operating Instructions
RFRB - RF Room Thermostat
Contents
1. Factory default settings
2. Specification & wiring
3. Mounting
CAUTION!
Before commencing any work on the electrical
connections, you must first disconnect the device from
the mains. None of the 230V connections must be live
until the installation has been completed and the housing
is closed. Only qualified electricians or authorised service
staff are permitted to open the terminal box.
4. Installation
5. Button / symbol description
6. Resetting the thermostat
7. On / Off function
8. Lock function
9. To connect the RFRB thermostat to the
R_7-RF programmer
There are parts that carry mains voltage behind the cover.
The terminal box must not be left unsupervised when
open. (Prevent non specialists and especially children
from gaining access to it.)
10. To disconnect the RFRB thermostat from
the R_7-RF programmer
Ensure that this wireless enabled programmer is installed
1 Metre from any metalic object, television, radio or
wireless internet transmitter.
Important: Keep this document
Prior to setting the thermostat, it is neccessary to complete all required settings described in this
section.
5. Button / symbol description
1. Factory default settings
Wireless symbol
Temperature indicator:
Switching differential:
In built frost protection:
Keypad lock:
°C
Heating ON symbol
Room temperature
0.2°C
5°C
Off
Battery low symbol
On / Off button
Set point handwheel
2. Specifications & wiring
Power Supply:
2 x AAA Alkaline Battery
50 uA
Power consumption:
Battery replacement:
Temp. Control Range:
Dimensions:
Once per year
5...35°C
84 * 84 * 30mm
NTC 10K Ohm @ 25°C
°C
Temp. sensor:
Temp. indication:
Reset button Code button
3. Mounting
6. Resetting the thermostat
The mounting height should be 1.5 meters above the floor level. The
thermostat should be wall mounted in the room where the heating is to
be controlled.
Press the
button on the bottom of the thermostat, the front housing
will detach from the baseplate.
Insert the batteries into the thermostat.
The place of installation should be chosen so that the sensor can measure
the room temperature as accurately as possible.
Press the reset button on the PCB, ‘NO’will flash on the screen.
Rotate the hand wheel clockwise until ‘YES’appears on the screen.
Press the hand wheel once to confirm the setting.
Choose the mounting location to prevent direct exposure to sunlight or
other heating / cooling sources when mounted.
The thermostat has now been reset and the current temperature will
appear on the screen.
The unit can be fitted to:
1. Recessed conduit boxes
2. Surface mounting boxes
3. Directly on walls
4. Table mounting with stand provided
7. On / Off function
Press the On/Off button to turn the zone paired with the thermostat on
or off.
4. Installation
The paired zone of the programmer must be in the following states for
this function to operate:
Press the button on the bottom of the thermostat.
The front housing will detach from the baseplate.
Insert the batteries (provided) into the thermostat.
Mount the unit as described in section 3.
In permanently ON mode
In Allday mode and zone in ON
In Auto mode and zone is ON
Offer the baseplate up to the thermostat. Snap it into position to close.
If the zone is timed off or in permanently OFF mode the On/Off button on
the thermostat will not operate
EPH Controls Ireland
EPH Controls UK
20221108_RFRB_OpIns_PK
| General | Details |
|---|---|
| Name | EPH CONTROLS RFRB RF Room Thermostat Instruction Manual |
| Make | EPH CONTROLS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.11 MB |

EPH CONTROLS eTRV-HW Smart Cylinder Thermostat User Guide

EPH CONTROLS eTRV-HW Smart Hot Water Thermostat Instruction Manual

EPH CONTROLS eTRV Smart Radiator Thermostat Instruction Manual

EPH CONTROLS 20221026 RFRA – RF Room Thermostat Instruction Manual

EPH CONTROLS CDTP2 Hardwired Room Thermostat Instruction Manual

EPH Controls CDT2-24 24V Room Thermostat Installation Guide

EPH CONTROLS RFCA RF Cylinder Thermostat Instruction Manual

EPH CONTROLS PR092K7 RF Cylinder Thermostat Instruction Manual

EPH CONTROLS COMBIPACK2 Smart Thermostat with Automation and Optimum Start Instructions

EPH CONTROLS CMF Room Frost Thermostat Instruction Manual

EPH CONTROLS RFRB RF Room Thermostat Instruction Manual Overview
Summary of Contents
- Page 1: Operating instructions for the RFRB - RF room thermostat include important sections on factory default settings, specifications and wiring, mounting, installation, button and symbol descriptions, resetting the thermostat, on/off function, and lock function. Before commencing any work on electrical connections, disconnect the device from the mains. Only qualified electricians or authorized service staff are permitted to open the terminal box. The thermostat should be wall mounted at a height of 1.5 meters above floor level in the room where heating is to be controlled. Insert the batteries into the thermostat and choose the installation location to ensure accurate temperature measurement. Press the reset button on the PCB to reset the thermostat, confirming the setting by rotating the hand wheel. The paired zone of the programmer must be in specific states for the on/off function to operate correctly. The thermostat can be fitted to recessed conduit boxes, surface mounting boxes, directly on walls, or table mounting with the provided stand. Ensure the wireless enabled programmer is installed at least 1 meter away from metallic objects and other electronic devices. Keep this document for reference prior to setting the thermostat.
- Page 2: Operating instructions for the RFRB - RF room thermostat include a lock function. To lock the thermostat, press the hand wheel for 10 seconds until the lock symbol appears. To unlock, press the hand wheel for 10 seconds again until the lock symbol disappears. Connecting the RF thermostat with the programmer involves lowering the cover on the front of the timeswitch and moving the selector switch to the RUN position. Press the button on the timeswitch for 5 seconds until Wireless Connect appears on the screen. On the RFRB thermostat, press the Code button located inside the housing on the Printed Circuit Board. Available zones will begin to flash on the timeswitch; press the button for the desired zone to connect. The thermostat will indicate the connection status with r1, r2, etc., for the respective zones. To disconnect the RF thermostat from the programmer, follow similar steps to access the Wireless Connect screen and clear all RF connections. This process will disconnect all thermostats from the timeswitch/programmer.