HYSEN HY02B05RF Wireless Heating Thermostat User Manual
Icon Instruction
HY02B05RF Wireless Heating Thermostat User Manual
Programmable Mode Setting
Power on state, long press “ ” enter into first time period (hour setting), press “ ” and “ ” to
adjust value, short press “ ” enter into minute setting, press “ ” and “ ” to adjust value, then short
press “ ” enter into temperature setting, press “ ” and “ ” to adjust value, successively short press
Product Specifications
☆ Power Supply: Receiver:230Vac 50/60HZ
☆ Range of temperature display: 0~40°C
“
” to set second time period, thirdly time period ......
Transmitter: 2AA* 1.5V alkaline batteries
☆ Display accuracy: 0.5°C
☆ Probe sensor: NTC(10k)1%
☆ Insulating condition: Normal environment
☆ Running program: Set per 1 week as a cycle
Wake up
Out door
Back home
Out door
Back home
Sleep
☆ Contact capacity: 5A/250V(BW;WW);16A/250V(WE)☆ Output: Switch relay
11:00
13:30
17:00
22:00
6:00 21℃ 8:00 17℃
21℃
17℃
21℃
17℃
☆ Working environment temperature: 0~70°C
☆ Range of temperature adjustment: 5~35°C
☆ Installation: Wall mounted or on battery seat
☆ Size(mm):86*86*27
Advanced options
Power off state, long press
From A1 to Ao, short press
for 3-5 seconds to access advanced setting A.
to choose the option, and adjust data by
Operation Key
,
. After finish setting ,remain
NO
symbols represent
about 10 seconds ,it will save setting and exit advanced setting automatically .
NO
Turn ON/OFF: Short press to turn on/ turn off
A
Setting Options
Data Setting Function
Factory Default
Display
1 Short press
to switch automatic mode and manual mode
for 3-5 seconds to enter into programmable
B
Measure Temperature
Calibration
-9-+9℃
2 Turn on thermostat, long press
A1
measuring
temperature
1℃
press
,
to adjust.
setting
3. Turn off thermostat, long press
settingA
for 3-5 seconds to enter into advanced
Temperature control return 0.5-5℃
A2
difference setting
1 Confirm key: Only short press it to set time
A3 Children lock setting
0:half lock
1:full lock
0
0
C
2 Tunr on thermostat,long press 3-5 seconds,When the OFF flashes press
or
0: Last State
instead ON,short press
to seting days and temperature of the holiday
A4 Power off Memory
1: Electricity turn off
2: Electricity turn on
P1: 5+2
mode.press
will open holiday mode.
3 Turn off thermostat, long press it for 3-5seconds to enter into advanced setting B
P1
A5 Weekly programming selection
P2: 6+1
1 Decrease key
B
P3: 7
2 Long press to lock /unlock
1 Increase key :
A6 Setting temperature lowest limit
1-10℃
5℃
D
A7 Setting temperature highest Limit 20-70℃
35℃
2 Under auto mode state, press
,
to enter into temporary manual mode
1: 1-10℃
3 Long press to check external sensor temperature(only used for the receiver with
external sensor)
A8 Anti-freezing function
2: more than 10℃ ,display -- ,then
mean closed this function
1: 20-70℃
5℃
--
Highest temperature protection
A9
2: less than 20℃,display --,then mean
function
closed this function
| General | Details |
|---|---|
| Name | HYSEN HY02B05RF Wireless Heating Thermostat User Manual |
| Make | HYSEN |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.36 MB |

HYSEN HY518WE WIFI Digital Heating Thermostat User Manual

HYSEN HY312 Wi-Fi Digital Heating Thermostat Instruction Manual

HYSEN HY510 WiFi Heating Thermostat Instruction Manual

HYSEN HY511 WiFi Heating Thermostat Owner’s Manual

HYSEN HY608 Wi-Fi Digital Heating Thermostat User Manual

HYSEN HY09RF WI-FI Wireless Thermostat User Manual

HYSEN HY02DB-WIFI Wifi Plug In Thermostat User Manual

HYSEN HY02B05RF Manual: Questions and Answers
What is the difference between manual and automatic mode on HYSEN HY02B05RF?
Automatic mode follows your programmed schedule. Manual mode lets you set a temporary temperature that overrides the weekly program. User Manual, p. 1
Can I set different temperatures for weekdays and weekends on HYSEN HY02B05RF?
Yes. Select weekly programming mode A5 with options P1 (5+2), P2 (6+1), or P3 (7 days). Each option groups weekdays and weekends differently. User Manual, p. 1