HYSEN HY02B05RF Wireless Heating Thermostat User Manual
Icon Instruction
HY02B05RF Wireless Heating Thermostat User Manual
Programmable Mode Setting
Power on state, long press “ ” enter into first time period (hour setting), press “ ” and “ ” to
adjust value, short press “ ” enter into minute setting, press “ ” and “ ” to adjust value, then short
press “ ” enter into temperature setting, press “ ” and “ ” to adjust value, successively short press
Product Specifications
☆ Power Supply: Receiver:230Vac 50/60HZ
☆ Range of temperature display: 0~40°C
“
” to set second time period, thirdly time period ......
Transmitter: 2AA* 1.5V alkaline batteries
☆ Display accuracy: 0.5°C
☆ Probe sensor: NTC(10k)1%
☆ Insulating condition: Normal environment
☆ Running program: Set per 1 week as a cycle
Wake up
Out door
Back home
Out door
Back home
Sleep
☆ Contact capacity: 5A/250V(BW;WW);16A/250V(WE)☆ Output: Switch relay
11:00
13:30
17:00
22:00
6:00 21℃ 8:00 17℃
21℃
17℃
21℃
17℃
☆ Working environment temperature: 0~70°C
☆ Range of temperature adjustment: 5~35°C
☆ Installation: Wall mounted or on battery seat
☆ Size(mm):86*86*27
Advanced options
Power off state, long press
From A1 to Ao, short press
for 3-5 seconds to access advanced setting A.
to choose the option, and adjust data by
Operation Key
,
. After finish setting ,remain
NO
symbols represent
about 10 seconds ,it will save setting and exit advanced setting automatically .
NO
Turn ON/OFF: Short press to turn on/ turn off
A
Setting Options
Data Setting Function
Factory Default
Display
1 Short press
to switch automatic mode and manual mode
for 3-5 seconds to enter into programmable
B
Measure Temperature
Calibration
-9-+9℃
2 Turn on thermostat, long press
A1
measuring
temperature
1℃
press
,
to adjust.
setting
3. Turn off thermostat, long press
settingA
for 3-5 seconds to enter into advanced
Temperature control return 0.5-5℃
A2
difference setting
1 Confirm key: Only short press it to set time
A3 Children lock setting
0:half lock
1:full lock
0
0
C
2 Tunr on thermostat,long press 3-5 seconds,When the OFF flashes press
or
0: Last State
instead ON,short press
to seting days and temperature of the holiday
A4 Power off Memory
1: Electricity turn off
2: Electricity turn on
P1: 5+2
mode.press
will open holiday mode.
3 Turn off thermostat, long press it for 3-5seconds to enter into advanced setting B
P1
A5 Weekly programming selection
P2: 6+1
1 Decrease key
B
P3: 7
2 Long press to lock /unlock
1 Increase key :
A6 Setting temperature lowest limit
1-10℃
5℃
D
A7 Setting temperature highest Limit 20-70℃
35℃
2 Under auto mode state, press
,
to enter into temporary manual mode
1: 1-10℃
3 Long press to check external sensor temperature(only used for the receiver with
external sensor)
A8 Anti-freezing function
2: more than 10℃ ,display -- ,then
mean closed this function
1: 20-70℃
5℃
--
Highest temperature protection
A9
2: less than 20℃,display --,then mean
function
closed this function
| General | Details |
|---|---|
| Name | HYSEN HY02B05RF Wireless Heating Thermostat User Manual |
| Make | HYSEN |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.36 MB |

HYSEN HY518WE WIFI Digital Heating Thermostat User Manual

HYSEN HY312 Wi-Fi Digital Heating Thermostat Instruction Manual

HYSEN HY510 WiFi Heating Thermostat Instruction Manual

HYSEN HY511 WiFi Heating Thermostat Owner’s Manual

HYSEN HY608 Wi-Fi Digital Heating Thermostat User Manual

HYSEN HY09RF WI-FI Wireless Thermostat User Manual

HYSEN HY02DB-WIFI Wifi Plug In Thermostat User Manual

HYSEN HY02B05RF Wireless Heating Thermostat User Manual Overview
Summary of Contents
- Page 1: Icon instruction Wireless heating thermostat user manual Programmable mode setting Power on state, long press to enter into first time period (hour setting). Product specifications Power supply: Receiver: 230Vac 50/60Hz Range of temperature display: 0~40°C Display accuracy: 0.5°C Probe sensor: NTC(10k)1% Running program: Set per 1 week as a cycle Installation: Wall mounted or on battery seat Advanced options Turn ON/OFF: Short press to turn on/turn off Setting options Factory default display Temperature control return 0.5-5°C difference setting
- Page 2: Return different temperature of 1-9 ℃. High temperature protection. Long press the whole screen for 3-5 seconds to access advanced setting. Restore factory defaults in power off state, long press. To prevent the thermostat display from high fluctuation, special treatment has been made to the program. The thermostat installed on 1.5m above the ground. Avoid installing in wall corners, door/window sides, or unheated areas. Only professional technicians are permitted to open the transmitter and receiver box of the thermostat. Before installing the thermostat, make sure that the system is disconnected. We offer a warranty of 18 months from the sales day.