Home > Drayton > Drayton RF710 Digital Wireless Room Thermostat Installation Guide

Drayton RF710 Digital Wireless Room Thermostat Installation Guide

Adjust this setting to suit the heating system capability.  
current setting.  
(Mains version only)  
= Fast – the house usually reaches setpoint in < 1 hour  
= Slow – the house usually reaches setpoint in > 1 hour  
Once a value has been changed, pressing ‘On’ before exiting the menu  
will save the new setting.  
To return to normal operation, either press and and hold the ‘Off & +’  
buttons for more than 5 seconds or wait for 1 minute and it will return  
automatically.  
1.Internal temperature sensor has failed.  
2.Ambient temperature is outside product operating temperature range.  
Remove the battery cover using a coin (Fig ).  
Install the 2 AA batteries provided (Fig ).  
Technical Data  
2 x AA Size, 1.5V alkaline batteries  
SPDT 16(2)A 230V a.c. Volt free  
10mA@24V a.c. (inductive)  
(Fig  
)
(Fig  
)
433 MHz  
30m typically. The range may be affected by  
the composition / density and number of  
walls between the Digistat RF and SCR.  
Replace battery cover (fig ).  
5 to 30ºC  
+ 0.5K @ 20ºC  
Operating 0ºC to 40ºC /  
Storage –20ºC to 55ºC  
Suitable for surface or conduit box  
mounting  
(Fig  
)
Designed for fixed wiring only, to comply  
with current IEE wiring regulations (BS7671).  
No wiring required  
The Digistat is now installed and will automatically start to control  
the room temperature.  
75ºC  
2
The following installer options can be adjusted,  
1.Application Type  
7.5  
5
2.System Capability  
IV = 2% (According to EU 811/2013,  
812/2013, 813/2013, 814/2013)  
than 5 seconds – the display will show ‘Inst’ (Installer menu) as shown,  
230V a.c.  
SPDT (voltage free) 2(1)A 230V a.c. or  
24V a.c./d.c.  
Designed for fixed wiring only, to comply  
Press the 'On' button until 'Ap:ty' (Application Type) is shown with the  
current setting  
with current IEE wiring regulations (BS7671).  
433 MHz  
/5 /E RE Directive  
2006/66/EC Battery Directive  
2011/65/EU RoHS Directive  
2012/19/EU WEEE Directive  
EN60730-1; EN60730-2-9 EN  
300 220-2; EN 301 489-3  
= Gas Boiler  
= Oil Boiler  
Schneider Electric  
401 Southway Drive  
Plymouth  
PL6 6QT  
United Kingdom  
Schneider Electric  
35 Rue Joseph Monier  
France-92500 Rueil Malmaison  
= Electric Heat (Relay model only)  
Once a value has been changed, pressing ‘On’ before exiting the menu  
will save the new setting.  
se.com/contact  
GeneralDetails
NameDrayton RF710 Digital Wireless Room Thermostat Installation Guide
MakeDrayton
LanguageEnglish
FiletypePDF (Download)
File size1.06 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Drayton RF902 Digistat 3rd Generation Wireless 2-Channel Programmable Thermostat Installation Guide
Drayton RF902 Digistat 3rd Generation Wireless 2-Channel Programmable Thermostat Installation Guide
Drayton Wiser Smart Room Thermostat Instruction Manual
Drayton Wiser Smart Room Thermostat Instruction Manual
Drayton 2290M Digistat 3rd Generation Programmable Room Thermostat Installation Guide
Drayton 2290M Digistat 3rd Generation Programmable Room Thermostat Installation Guide
Drayton 22902 Programmable 2 Channel Room Thermostat Installation Guide
Drayton 22902 Programmable 2 Channel Room Thermostat Installation Guide
Drayton 2290M Mains Digital Room Thermostat User Manual
Drayton 2290M Mains Digital Room Thermostat User Manual

Drayton RF710 Digital Wireless Room Thermostat Installation Guide