Drayton RF710 Digital Wireless Room Thermostat Installation Guide
Switched
Internal
boiler
electronics
230V a.c.
fused 3A,
L -
N -
External
controls
connections
+
Digistat 1 &
+
Digistat 1RF
Digistat + RF
N
L
1
2
3
Room Thermostat
Models:
+
Digistat 1RF
SCR
Radio signals
to SCR - no wiring
RF710/22190/2219
Switched live
from wiring
centre
Motorised valve
N
To boiler
and/or
pump
L
230V a.c.
fused 3A
06515065001 ISS G
Drayton Controls reserve the right
to make changes without notice
and cannot accept liability for errors.
Digistat + RF
N
L
1
2
3
+
Digistat 1RF
Radio signals
to SCR - no wiring
SCR
User Guide
Standard for all models
IMPORTANT: MULTIZONE INSTALLATIONS ONLY
If more than one ‘wireless system’ is fitted within the same property.
ie. for controlling 2 or more zones (multi-zone) it is essential that the
Digistat RF units are matched correctly to the relevant SCR. This is easily
achieved by commissioning each Digistat and SCR in turn.
What is a room thermostat?
... An explanation for householders
1. Install (see installation instructions) and turn power on to the
SCR (receiver). If a separate programmer is fitted, ensure that it is
switched on. The red LED should come on.
A room thermostat simply switches the heating system on
and off as necessary. It works by sensing the air temperature,
switching on the heating when the air temperature falls below
the thermostat setting, and switching it off once this set
temperature has been reached.
2. Push the ‘override’ button on the SCR once. The green LED should
also come on. Check to see if the boiler and/or motorised valve
are working.
3. To enter ‘learn’ mode push the button marked 1 followed by 2
(OVERRIDE) and hold both depressed together. The red LED
should flash for 2 seconds and then go out signifying the SCR is in
learn mode. Release both buttons.
Turning a room thermostat to a higher setting will not make
the room heat up any faster. How quickly the room heats up
depends on the design of the heating system, for example, the
size of boiler and radiators.
4. The red and green LED’s should both now be on.
Neither does the setting affect how quickly the room cools
down. Turning a room thermostat to a lower setting will result
in the room being controlled at a lower temperature, and saves
energy.
5. Take the Digistat RF and hold it within sight of the SCR (no closer
than one metre).
6. Remove the battery cover and fit the batteries.
7. The Digistat RF should now display the actual room temperature.
If the unit has been stored in a cold place, it may take time to warm
up.
The heating system will not work if a time switch or programmer
has switched it off.
The way to set and use your room thermostat is to find the
lowest temperature setting that you are comfortable with,
and then leave it alone to do its job. The best way to do this
is to set the room thermostat to a low temperature – say 18ºC
– and then turn it up by one degree each day until you are
comfortable with the temperature. You won’t have to adjust the
thermostat further. Any adjustment above this setting will waste
energy and cost you more money.
8. As soon as the batteries are fitted, the red LED on the SCR should
flash for 7 seconds and then go out.
The green LED may be on or off depending on the room temperature
at the time of commissioning.
9. If the red LED remains on, remove the batteries on the Digistat RF,
check the battery positions are correct, and once the display has
faded, repeat steps 6 to 8.
10. Increase the ‘SET’ temperature on the Digistat RF by pressing the
+ button until a flame symbol appears, in the left hand segment of
the display.
If your heating system is a boiler with radiators, there will
usually be only one room thermostat to control the whole
house. But you can have different temperatures in individual
rooms by installing thermostatic radiator valves (TRVs) on
individual radiators. If you don’t have TRVs, you should choose
a temperature that is reasonable for the whole house. If you do
have TRVs, you can choose a slightly higher setting to make sure
that even the coldest room is comfortable, then prevent any
overheating in other rooms by adjusting the TRVs.
11. The red LED on the SCR should flash for 7 seconds. This confirms
that the radio signal is being sent and received. After 7 seconds the
red LED should go out and the green one come on.
12. Check to confirm that the boiler and/or motorised valves are
working.
13. Decrease the ‘SET’ temperature on the Digistat RF by pressing the
- button until the flame symbol disappears.
Room thermostats need a free flow of air to sense the
temperature, so they must not be covered by curtains or
blocked by furniture. Nearby electric fires, televisions, wall or
table lamps may prevent the thermostat from working properly.
14. The red LED on the SCR should flash for 7 seconds. After 7 seconds
both the red and green LEDs should go out. Check that the boiler
and/or motorised valve have powered down.
15. Place the Digistat RF in the chosen operating position, (see Digistat
RF location section) and repeat steps 10 to 14. Once you have
confirmed the sy stem oper ates correctly, fi t and secure the Digistat RF
to the wall (see installation instructions).
During normal operation the red LED on the SCR will flash for 7 seconds
each time a radio signal is received from the Digistat RF. This will occur
approximately every 5 minutes.
The green LED on the SCR denotes a call for heat (ON).
| General | Details |
|---|---|
| Name | Drayton RF710 Digital Wireless Room Thermostat Installation Guide |
| Make | Drayton |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.06 MB |

Drayton RF902 Digistat 3rd Generation Wireless 2-Channel Programmable Thermostat Installation Guide

Drayton Wiser Smart Room Thermostat Instruction Manual

Drayton 2290M Digistat 3rd Generation Programmable Room Thermostat Installation Guide

Drayton 22902 Programmable 2 Channel Room Thermostat Installation Guide

Drayton 2290M Mains Digital Room Thermostat User Manual