DEVI 140F1161 Intelligent Electronic Timer Controlled Thermostat Installation Guide
DEVIreg™ Room
3. The bending radius for the
Flexpipe must be more than
50 mm.
4. Make sure the floor sensor is
located with equal distances
between two heating
cables (> 2 cm) located at a
representative position.
5. For thin floor constructions:
the Flexpipe should be flush
with the sub-floor surface,
countersink the Flexpipe if
possible.
1
2
≥
For thicker constructions: the
Flexpipe including the sensor
should be located such that
the sensor is exposed to a
representative heating level,
our recommendation is still
that the sensor must be located
equidistant between the cables
or mat runs.
10
Installation Guide