PROGRAMMING
PlanningYour Program – Important
The Heating and Cooling Program schedules below allow you
to pencil in your own program times and temperatures.
The 1F85-0422 comes configured for 5/1/1 day programming
and can also be configured for 5/2 day programming (see
configuration section).
If you are re-programming a 5+1+1 fill in all lines with the
times and temperatures you want.
Keep the following guidelines in mind when planning your
program.
•InHeating,lowertemperatureswillsaveenergy.
•InCooling,highertemperatureswillsaveenergy.
•IfyouplanonusingAutoChangeover,donotprogram
the heating higher than the cooling.
Factory settings are listed on Monday through Friday, Satur-
day and Sunday. If you are re-programming a 5/2 day sched-
ule, pencil in your own times and temperatures directly below
the factory times and temperatures.
Worksheet for Re-Programming 5/2 Day and 5+1+1 Day Program
Heating
Program
Wake Up
(Period 1)
Leave For Work Return Home
(Period 2) (Period 3)
Go To Bed
(Period 4)
6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F
6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F
6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F
Mon-Fri
Sat-Sun
or Sat
Sun
5+1+1 only
Cooling
Program
Wake Up
(Period 1)
Leave For Work Return Home
(Period 2) (Period 3)
Go To Bed
(Period 4)
6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F
6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F
6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F
Mon-Fri
Sat-Sun
or Sat
Sun
5+1+1 only
TROUBLESHOOTING
Comfort Alert Codes
Comfort AlertYellow Alert Codes
The Comfort Alert diagnostics product monitors the air
conditioning outdoor systems with single phase Copeland
Scroll compressors. Abnormal system and electrical
conditions are indicated by flashing ALERT codes on the
yellow LED on the Comfort Alert module. The flash codes are
transmitted to the thermostat by the Comfort Alert Thermostat
interface module. The Comfort Alert compatible thermostat
displays “Call For Service” that flashes at the same rate as
the yellow LED on the Comfort Alert module.
1 Flash
Long run time
System pressure trip
Short cycling
2 Flashs
3 Flashs
4 Flashs
5 Flashs
6 Flashs
7 Flashs
8 Flashs
9 Flashs
Locked rotor
Open circuit
Open start circuit
Open run circuit
Welded Contactor
Low voltage
8
| General | Details |
|---|---|
| Name | White Rodgers 1F85-0422 Blue Universal Thermostat Instruction Manual |
| Make | WHITE RODGERS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.38 MB |

White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual

White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual

White-Rodgers 1F56N-444 Thermostat User Manual

White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual

White-Rodgers M30 Thermostat Instruction Manual

WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual

White Rodgers 1F78-151 Non Programmable Thermostat Instructions

WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual

WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual

WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual