Home > PRO1 > PRO1 T731W Wireless PTAC Non-Programmable Thermostat Installation Guide

PRO1 T731W Wireless PTAC Non-Programmable Thermostat Installation Guide

Technician Setup  
Technician Setup  
LCD Will Show Adjustment Options  
Default  
LCD Will Show Adjustment Options  
Default  
Tech Setup Steps  
Tech Setup Steps  
Select Gas (GS) for applications  
EL = Electric for thermostat  
control  
This setting protects the  
compressor from “short cycling”.  
When ON, the compressor will  
ON = Turns 5 minute delay on  
OF(OFF) = Removes the delay  
where the air handlers controls  
the fan during a call for heat.  
Slect Electric (EL) if you would like  
the thermostat to control the fan  
during a call for heat.  
Compressor  
Fan  
Operation  
EL  
Electric  
ON  
GS = Gas for system control  
Short Cycle delay for 5 minutes after it was  
last turned off.  
COMP DELAY  
90  
FAN SET  
Set a maximum heat setpoint  
Heating  
Temperature  
45.0 - 90.0˚ F  
7.0 - 32.0˚ C  
Select number of fan stages you  
would like the thermostat to  
operate.  
1 = 1 Speed: On, Auto  
2 = 2 Speed: Low (On L), High  
(On H), Auto  
3 = 3 Speed: Low (On L), Med  
(On M), High (On H), Auto  
value. Once set, the setpoint  
2 Speed:  
temperature cannot be raised  
HE  
90˚  
44˚  
N/A  
Setpoint Limit  
above this value.  
Low  
High  
Auto  
Fan Speeds  
2
HEAT LIMIT  
FANSPEEDS  
Set a minimum cool setpoint  
valve. Once set, the setpoint  
temperature cannot be lowered  
below this value.  
44  
45.0 - 90.0˚ F  
7.0 - 32.0˚ C  
Cooling  
Temperature  
Setpoint  
Limit  
Select the terminal you would  
like to use to operate the medium  
speed fan. (only if fan speed is  
set to 3)  
O or B  
Medium  
Speed Fan  
Terminal  
44  
COOL LIMIT  
P
0
O
F
M FANTERM  
Designation  
This setting is a secondary way to  
pair the thermostat with the base  
module.  
Press the “+”button to enter  
paring mode  
Select F for Fahenheit  
temperature or C for Celsius.  
F = Fahrenheit  
Enter  
Network  
(Only displayed if you  
are not paired)  
F or C  
C = Celsius  
F OR C  
START PAIR  
The display light can be  
configured to stay on  
permanently or only when a key  
is pressed.  
OF = OFF configures the  
OF  
display light to come on when  
the light key or any button is  
pressed.  
Exit network (only displayed if  
you are paired).  
Press the “+”button to exit the  
network  
UP  
Exit  
N/A  
N/A  
Network  
(Only displayed if you  
are not paired)  
OFF when  
battery  
powered  
/ LOW  
when  
hardwired  
NOTE: HARDWIRE ONLY. Keeping  
the display light continually “ON”  
will greatly reduce battery life.  
LO = LOW configures the  
display light to stay on at a  
lower intensity until a button is  
pressed and then it goes to the  
normal high intensity.  
Display Light  
dL  
UNPAIR  
DISP LIGHT  
View the strength of the wireless  
signal. 1 indicates a weak signal  
and 5 indicates a strong signal.  
1-5  
Signal  
Strength  
(Only shows if you  
are paired)  
HI = HIGH configures the dis-  
play light to stay on at normal  
high intensity all the time.  
3
SIG STR  
When turned on the thermostat  
will operate a heat pump. Y will  
be the first stage of heat & cool,  
W will be the second stage of  
heat.  
OFF configures the thermostat  
for non heat pump systems.  
ON configures the thermostat  
for heat pump systems.  
Heat Pump  
OF  
OFF  
HEAT PUMP  
13  
14  
Technician Setup  
Technician Setup  
Occupancy Models Only  
Occupancy Models Only  
LCD Will Show Adjustment Options  
LCD Will Show Adjustment Options  
Default  
Default  
Tech Setup Steps  
Tech Setup Steps  
When using the Occupancy model  
Set the heat temperature and fan  
operation that you would like the  
system to be while the space is  
unoccupied.  
ON  
OF(OFF)  
Full temperature range  
defined by setpoint limits.  
Unoccupied  
the installer can choose to utilize  
the occupancy sensor to set back  
the room temperature while it is  
not being occupied.  
Local  
Occupancy  
Sensor  
Heat Setting  
(Only displayed if  
Local Occupancy  
Sensor is ON)  
0F  
First adjust the temperature  
using the + and – buttons.  
Use the Fan button to  
OF  
62  
62˚  
OCC SENSOR  
UNOCC COOL  
change the fan operation.  
When the occupancy sensor is  
turned on you have the ability  
to set how long the thermostat  
will go into occupancy mode  
everytime a person is sensed.  
30 = 30 minutes, 1 = 1 hour,  
2 = 2 hours, 3 = 3 hours, 4  
= 4 hours, 5 = 5 hours, 6 =  
6 hours, 7 = 7 hours, 8 =8  
hours, 9 = 9 hours, 10 = 10  
Duration of  
Set the level of sensitivity of  
the occupancy sensor. Lowering  
the sensitivity will cause the  
sensor to respond only to larger  
movements.  
High Sensitivity:  
This is the most sensitive  
setting and  
will detect very slight  
motions. This is the  
recommended setting  
because it will work well for  
nearly all applications,  
and will detect any  
movement.  
Occupancy  
(Only displayed if  
Local Occupancy  
Sensor is ON)  
8
8
OCC LENGTH  
hours, 11 = 11 hours, and 12  
= 12 hours.  
Set the cooling temperature and  
fan operation that you would like  
the system to be while the space  
is being occupied.  
Full temperature range  
defined by setpoint limits.  
Occupied  
Occupancy  
Sensitivity  
Setting  
(Only displayed if  
Local Occupancy  
Sensor is ON)  
Cool Setting  
(Only displayed if  
Local Occupancy  
Sensor is ON)  
First adjust the temperature  
using the + and – buttons.  
Use the Fan button to change  
the fan operation.  
75  
78˚  
70˚  
83˚  
HI  
Medium Sensitivity:  
OCC COOL  
HI  
This is the medium sensitive  
setting and can be used  
without pets setting it off.  
Set the heating temperature and  
fan operation that you would like  
the system to be while the space  
is being occupied.  
Full temperature range defined  
by setpoint limits.  
Occupied  
Low Sensitivity:  
Heat Setting  
(Only displayed if  
Local Occupancy  
Sensor is ON)  
This is the least sensitive  
setting and can be used in  
areas of heavy traffic. This will  
not be set off by pets, small  
children, or people more than  
20’from the sensor location.  
First adjust the temperature  
using the + and – buttons.  
Use the Fan button to change  
the fan operation.  
70  
OCC HEAT  
Set the cool temperature and fan  
operation that you would like the  
system to be while the space is  
unoccupied.  
Full temperature range defined  
by setpoint limits.  
Unoccupied  
Maximize efficiency and  
equipment longevity by  
ON  
OF(OFF)  
Cool Setting  
(Only displayed if  
Local Occupancy  
Sensor is ON)  
First adjust the temperature  
using the + and – buttons.  
UNOCC HEAT Use the Fan button to change  
the fan operation. normal high  
intensity all the time.  
83  
increasing the heating and  
cooling swing settings to 2.0˚  
during the unoccupied and leave  
time periods. This will result in  
significantly fewer system cycles.  
Cycle  
Minimizer  
(Only displayed if  
local Occupancy  
Sensor is ON)  
0F  
OF  
CYCLE MIN  
15  
16  
GeneralDetails
NamePRO1 T731W Wireless PTAC Non-Programmable Thermostat Installation Guide
MakePRO1
LanguageEnglish
FiletypePDF (Download)
File size0.34 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
PRO1 T751i Thermostat Installation Guide
PRO1 T751i Thermostat Installation Guide
PRO1 T805 Non Programmable Thermostat Instruction Manual
PRO1 T805 Non Programmable Thermostat Instruction Manual
PRO1 T701 Digital Non Programmable Thermostat Instruction Manual
PRO1 T701 Digital Non Programmable Thermostat Instruction Manual
PRO1 IAQ T721i Digital WIFI Programmable Thermostat User Manual
PRO1 IAQ T721i Digital WIFI Programmable Thermostat User Manual
PRO1 R250W Wireless System Thermostat Owner’s Manual
PRO1 R250W Wireless System Thermostat Owner’s Manual
PRO1 T725 Thermostat User Guide
PRO1 T725 Thermostat User Guide
PRO1 T755 Heat 2 Cool Dual Fuel Thermostat User Manual
PRO1 T755 Heat 2 Cool Dual Fuel Thermostat User Manual
PRO1 T771 Programmable Electronic Thermostat Instructions
PRO1 T771 Programmable Electronic Thermostat Instructions

PRO1 T731W Wireless PTAC Non-Programmable Thermostat Installation Guide