Wiring  
Wiring  
Caution:  
Electrical Hazard  
Warning:  
Wiring Note:  
Note:  
All components of the control  
system and the thermostat  
installation must conform to  
Class II circuits per the NEC Code.  
Failure to disconnect the power  
before beginning to install this  
product can cause electrical  
shock or equipment damage.  
The thermostat and Base Module  
come factory linked (communicating)  
out of the box. However, if the link is  
lost, use the process on page 14 to  
re-link the devices.  
The base module is  
packaged with labeled  
thermostat wire. Wire  
appropriately into the  
PTAC board terminals.  
Thermostat Wiring Tips  
C Terminal  
The C (common wire) terminal does  
not have to be connected when the  
thermostat is powered by batteries.  
Wire Specifications  
Use shielded or non-shielded  
18-22 gauge thermostat wire.  
GH GL  
B
C
R
Y
W
O
Note:  
Most PTAC systems support two speed fan operation. In a single speed  
fan PTAC system or conventional single speed fan system, the GL terminal  
will be used and “Imust be selected in the Technician Setup Menu.  
Power supply  
Note:  
The thermostat must be set to O or B to match the changeover  
valve, O is the cool changeover valve, B is the heat chageover  
valve.  
The base module may be mounted  
using adhesive tape, such as  
double-sided tape or hook and loop  
strips. The base module must be  
hardwired (C & R terminals  
connected to 24V power). Use  
secondary source of securement to  
prevent module from dropping into  
condenser drain pan.  
The Aux. Heat Relay is energized as the second stage of heat.  
Typical 1H/1C System: 2 Speed Fan  
C
L2  
R
Y
L1  
COMPRESSOR  
RELAY  
Connecting to a PTAC:  
When connecting the Base Module  
to a PTAC, refer to the PTAC  
manufacturer instructions to enable  
remote thermostat operation.  
R
W
C
HEAT RELAY  
FAN LOW RELAY  
FAN HIGH RELAY  
GL  
GH  
9
10  
Wiring  
Technician Setup  
1. To enter Tech Setup Menu, press and hold  
2. Use or to select the desired valve for each setting.  
3. Tap previous or next to select different tech settings.  
and  
together for 3 seconds.  
Typical 1H/1C System: 1 Speed Fan  
C
L2  
L1  
4. To exit Tech Setup Menu, press and hold  
or wait 60 seconds.  
and  
together for 3 seconds  
R
COMPRESSOR  
RELAY  
Y
R
W
HEAT RELAY  
Important Tech Setting Notes  
C
FAN RELAY  
GL  
1. Tech settings must be transferred to the basemodule.  
2. The transfer happens automatically when you exit the tech menu.  
GH  
Typical 1H/1C Heat Pump System: 2 Speed Fan  
C
LCD Will Show Adjustment Options  
Default  
Tech Setup Steps  
This feature allows the installer to  
4 ˚ - -4 ˚  
L2  
L1  
change the calibration of the am-  
bient room temperature display.  
For example, if the thermostat  
reads 70 degrees and you would  
like it to read 72 then select +2.  
Room  
Temperature  
Calibration  
R
0
COMPRESSOR  
RELAY  
0˚F  
Y
R
CALIBRATE  
O
B
W
C
The swing setting, often called  
“cycle rate, “differential”or “antic-  
ipation”is adjustable and dictates  
how frequenlty the system cycles  
on and off. For example: A swing  
setting of 0.8˚ will turn the  
cooling on at approximately 0.8˚  
above the setpoint and turn the  
cooling off at approximately 0.8˚  
below the setpoint.  
0.2 ˚ - 2 ˚  
COOL CHANGE  
OVER VALVE  
FAN LOW RELAY  
FAN HIGH RELAY  
GL  
GH  
HEAT CHANGE  
OVER VALVE  
Cooling  
Swing  
0.8  
0.8˚  
0.8˚  
COOLSWING  
Typical 2H/1C Heat Pump System: 2 Speed Fan  
C
The swing setting, often called  
“cycle rate, “differential”or “antic-  
ipation”is adjustable and dictates  
how frequenlty the system cycles  
on and off. For example: A swing  
setting of 0.8˚ will turn the  
heating on at approximately 0.8˚  
below the setpoint and turn the  
heating off at approximately 0.5˚  
above the setpoint.  
0.2 ˚ - 2 ˚  
L2  
L1  
COMPRESSOR  
RELAY  
Heating  
Swing  
R
0.8  
O
B
AUX HEAT  
RELAY  
HEATSWING  
COOL CHANGE  
OVER VALVE  
FAN LOW RELAY  
FAN HIGH RELAY  
HEAT CHANGE  
OVER VALVE  
11  
12  
GeneralDetails
NamePRO1 T731W Wireless PTAC Non-Programmable Thermostat Installation Guide
MakePRO1
LanguageEnglish
FiletypePDF (Download)
File size0.34 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
PRO1 T751i Thermostat Installation Guide
PRO1 T751i Thermostat Installation Guide
PRO1 T805 Non Programmable Thermostat Instruction Manual
PRO1 T805 Non Programmable Thermostat Instruction Manual
PRO1 T701 Digital Non Programmable Thermostat Instruction Manual
PRO1 T701 Digital Non Programmable Thermostat Instruction Manual
PRO1 IAQ T721i Digital WIFI Programmable Thermostat User Manual
PRO1 IAQ T721i Digital WIFI Programmable Thermostat User Manual
PRO1 R250W Wireless System Thermostat Owner’s Manual
PRO1 R250W Wireless System Thermostat Owner’s Manual
PRO1 T725 Thermostat User Guide
PRO1 T725 Thermostat User Guide
PRO1 T755 Heat 2 Cool Dual Fuel Thermostat User Manual
PRO1 T755 Heat 2 Cool Dual Fuel Thermostat User Manual
PRO1 T771 Programmable Electronic Thermostat Instructions
PRO1 T771 Programmable Electronic Thermostat Instructions

PRO1 T731W Wireless PTAC Non-Programmable Thermostat Installation Guide