Home > nVent RAYCHEM > nVent RAYCHEM Green Leaf Programmable Thermostat Instruction Manual
nVent RAYCHEM Green Leaf Programmable Thermostat Instruction Manual
TABLE OF CONTENTS
1.ꢀDESCRIPTION.................................................................................................................................................................... 3
2.ꢀMOUNTING AND INSTALLATION........................................................................................................................................ 3
Mounting the Thermostat.......................................................................................................................................................................... 3
3.ꢀUSING THE THERMOSTAT ................................................................................................................................................. 5
The Display............................................................................................................................................................................................... 5
Display in manual on/off programme................................................................................................................................................... 5
Display in timer programme ................................................................................................................................................................ 5
The manual on/off programme.................................................................................................................................................................. 6
The timer programme ............................................................................................................................................................................... 6
4.ꢀSETTING THE CLOCK......................................................................................................................................................... 7
5.ꢀPROGRAMMING THE TIMER PROGRAMme........................................................................................................................ 7
6.ꢀINSTALLER MENU.............................................................................................................................................................. 8
7.ꢀTROUBLESHOOTING.......................................................................................................................................................... 9
8.ꢀTECHNICAL SPECIFICATION.............................................................................................................................................. 9
ATTENTION
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack
of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without
supervision.
2 | nVent.com/RAYCHEM
1.ꢀDESCRIPTION
The nVent RAYCHEM Green Leaf Thermostat is a Programmable Thermostat designed for Electrical Floor Heating. The
thermostat is designed to control your Electrical Floor Heating in order to give you the best possible comfort and the lowest
possible energy usage.
The Thermostat can work in 3 different temperature sensing modes:
• Floor Sensing mode
• Room Sensing mode
• Room Sensing mode with floor temperature limiter
The Thermostat has 2 programmes to choose from:
• Manual ON/OFF (Constant Single temperature)
• Timer programme (4 timer events/day)
To change from one programme to the other, just touch the intelligent leaf button“ ”.
2.ꢀMOUNTING AND INSTALLATION
Mounting the Thermostat
The installation of the Green Leaf must be performed by a qualified installer. The Green Leaf is a thermostat with protection
class IP21, make sure to comply with all local regulations when installing the thermostat. Green Leaf is intended for flush
mounting in a wall box. It should be positioned approximately 1.5 meters above the floor, protected from direct sunlight and
draughts. All electrical conduits passing into the wall box that contain cables must also be sealed to protect the thermostat
against draughts, e.g. with a piece of insulation in the conduit outlet.
Step 1: Switch off the power supply
Step 2: Detach the metallic support from the Thermostat using a screwdriver
nV
nV
ent
ent
nV
ent
Step 3: Screw the metallic support frame to the in-wall box
Step 4: Install the floor sensor (mandatory for floor sensing mode or room sensing mode with floor temperature limiter). The
floor sensor should be installed in a separate flexible conduit all the way to the end, covering the end of the sensor, for easy
replacement and to avoid possible signal disturbance on the sensor. For best control performance, position the floor sensor
between two heating cables as close as possible to the top floor surface.
Do not position the floor sensor tip closer than 3 cm to the heating cable.
The floor sensor cable can be extended up to 100 m with a separate standard installation cable
2 x 1.5 mm2 (230VAC).
nVent.com/RAYCHEM | 3
| General | Details |
|---|---|
| Name | nVent RAYCHEM Green Leaf Programmable Thermostat Instruction Manual |
| Make | nVent RAYCHEM |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.43 MB |

nVent RAYCHEM ETS-05 Electronic Thermostat Instruction Manual

nVent RAYCHEM RAYSTAT-EX-02 Mechanical Thermostat Installation Guide

nVent RAYCHEM Elexant 3500i Electronic Thermostat Installation Guide

nVent RAYCHEM RayStat-M2 Thermostat Instruction Manual

nVent RAYCHEM AT-TS-13 Surface Sensing Thermostat Instruction Manual

nVent RAYCHEM SENZ Wifi Programmable Floor Heating Thermostat User Guide

nVent RAYCHEM GM-TA Thermostat Instruction Manual