Step 5: Connect the electrical power supply, the sensor and the cold lead of the electrical floor heating system to the Green Leaf
according to the electrical diagram. If you connect heating cables exceeding 13A for constant wattage or 10A for self-regulating
cables you must use a contactor with an integrated suppression device.
For the earth connection of the floor heating, you must use a separate earth terminal connection block.
nV
ent
Step 6: Click the Green Leaf into the metallic support frame.
Step 7: Switch on the power again
Product specific information
The thermostat is compatible with nVent RAYCHEM QuickNet, T2Blue, T2Green, T2Black and T2Red heating solutions.
T2Red
Self-regulating heating cables have an inrush current when the floor is cold. In order to guarantee the life time of the thermostat,
the maximum load of the self-regulating application in nominal conditions is limited to 10A.
A 13A self-regulating load will reduce the life time of the relay contacts and the installation will not be covered by the Total
Care Warranty.
4 | nVent.com/RAYCHEM
| General | Details |
|---|---|
| Name | nVent RAYCHEM Green Leaf Programmable Thermostat Instruction Manual |
| Make | nVent RAYCHEM |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.43 MB |

nVent RAYCHEM ETS-05 Electronic Thermostat Instruction Manual

nVent RAYCHEM RAYSTAT-EX-02 Mechanical Thermostat Installation Guide

nVent RAYCHEM Elexant 3500i Electronic Thermostat Installation Guide

nVent RAYCHEM RayStat-M2 Thermostat Instruction Manual

nVent RAYCHEM AT-TS-13 Surface Sensing Thermostat Instruction Manual

nVent RAYCHEM SENZ Wifi Programmable Floor Heating Thermostat User Guide

nVent RAYCHEM GM-TA Thermostat Instruction Manual