Home > ENGO > ENGO EASYBATB Wired Battery Thermostat User Guide

ENGO EASYBATB Wired Battery Thermostat User Guide

Connection description for EASY230W / EASY230B  
Connection description for EASYBATW / EASYBATB  
AC 230V  
AC 230V  
a) Connection diagram  
for gas boiler  
a) Connection diagram  
Wired Battery Thermostat  
L
L
for gas boiler  
EASYBATW  
EASYBATB  
L
L
L
3V  
COM  
COM  
2 xAAA  
EASY230W  
EASY230B  
NO  
N
NO  
N
N
N
N
AC 230V  
EASY230W /  
EASYBATW  
EASY230B /  
EASYBATB  
b) Connection diagram  
to pump / actuator  
b) Connection diagram  
to pump / actuator  
AC 230V  
L
L
L
EASYBATW  
EASYBATB  
COM  
COM  
NO  
MAX  
3(1)A  
MAX  
3(1)A  
3V  
EASY230W  
2 xAAA  
Quick Guide  
EASY230B  
NO  
N
Distributor:  
Ver. 1  
Release date: III 2022  
QL CONTROLS Sp z o.o. Sp. k.  
43-262 Kobielice  
4 Rolna St.  
N
N
Poland  
c) Connection diagram  
to the control box  
c) Connection diagram  
to the control box  
EASYBATW  
EASYBATB  
EASY230W  
3V  
EASY230B  
2 xAAA  
Wired, non-programmable thermostat, battery powered (2xAAA) or 230V AC  
powered. It is used for wired control of heating or cooling devices and systems. It works  
by maintaining comfortable conditions in the room, in line with the setpoint  
temperature set by the user. It is connected directly to a heat source or wiring centre.  
For a better fit, the model is available in two colors. Safe, reliable, easy to use.  
COM NO  
COM NO  
L
N
Product Compliance  
This product complies with the following EU Directives: 2014/53/EU, 2011/65/EU  
N
L
SL1  
N
L
SL1  
1 - 8 Zones  
1 - 8 Zones  
ECB08M230  
ECB08M230  
Technical Informations  
control box  
control box  
N
SL1  
N
SL1  
Power supply  
Max current  
230V or 2xAAA batteries  
3 (1) A  
Legend:  
Temperature range  
Display temperature accuracy  
Control algorithm  
Communication  
5 – 35°C  
0,1°C  
TPI or Hysteresis ( 0.2°C to 2°C)  
Wired  
Boiler - Boiler connection* - Boiler’s  
contacts for ON/OFF thermostat  
(according to the boiler’s instructions)  
L, N - power supply  
COM, NO - voltage-free output  
SL1 - 230V control input in the control box  
Pump  
Valve  
Output control  
COM / NO (voltage-free)  
IP30  
- fuse  
IP protection class  
Dimension [mm]  
80 x 80 x 22 mm  
GeneralDetails
NameENGO EASYBATB Wired Battery Thermostat User Guide
MakeENGO
LanguageEnglish
FiletypePDF (Download)
File size0.22 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
ENGO E55W230WIFI Wi-Fi Thermostat User Guide
ENGO E55W230WIFI Wi-Fi Thermostat User Guide
ENGO E20i Series Wi-Fi Wireless Internet Thermostat User Guide
ENGO E20i Series Wi-Fi Wireless Internet Thermostat User Guide
ENGO EONEBATW, EONEBATB Internet Controlled Thermostat User Guide
ENGO EONEBATW, EONEBATB Internet Controlled Thermostat User Guide
ENGO E901 Programmable Wired Thermostat User Manual
ENGO E901 Programmable Wired Thermostat User Manual
ENGO E901 Wireless Internet Thermostat User Manual
ENGO E901 Wireless Internet Thermostat User Manual
ENGO EASY230W Wired Thermostat User Guide
ENGO EASY230W Wired Thermostat User Guide
Engo EFAN-230 Zigbee Smart Thermostat Owner’s Manual
Engo EFAN-230 Zigbee Smart Thermostat Owner’s Manual

ENGO EASYBATB Wired Battery Thermostat User Guide
Get the free PDF manual for the ENGO EASYBATB Wired Battery Thermostat User Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

ENGO EASYBATB Wired Battery Thermostat User Guide Overview

Summary of Contents

  • Page 1: Connection description for EASY230W / EASY230B Connection description for EASYBATW / EASYBATB Wired, non-programmable thermostat, battery powered (2xAAA) or 230V AC powered. It is used for wired control of heating or cooling devices and systems. It works by maintaining comfortable conditions in the room, in line with the setpoint temperature set by the user. Product compliance: This product complies with the following EU Directives: 2014/53/EU, 2011/65/EU. Power supply: 230V or 2xAAA batteries. Max current: 3 (1) A. Temperature range: 5 – 35°C. Display temperature accuracy: 0.1°C. Control algorithm: TPI or Hysteresis (0.2°C to 2°C).
  • Page 2: WARNING! To enter the service menu, press and hold the MINUS and PLUS buttons for 5 seconds. Use the buttons to choose a parameter. For the parameter selection to be confirmed, wait 3 seconds. The thermostat will go to the home screen. Set the minimum temperature setpoint limit. Set the maximum temperature setpoint limit. Displayed temperature can be calibrated in steps of 0.1°C. For the thermostat to work properly, it must be installed in a suitable place. Check the current battery status (%). Select whether the thermostat output has to work as Normally Open or Normally Closed.