NEOMITIS PRG7 RF 7 Day Two Channel Programmer with RF Room Thermostat Instruction Manual
6- The current program can be copy to
the next days. Press Yes to copy or No
to program manually the next day.
7- Slide the programming slider to
posiꢁon to confirm and program
ADVANCE
Advance: advance mode is a temporary
mode which allows you to switch ON the
system in advance, unꢁl the next On/Off
period end ꢁme.
the second channel.
constant
all day
auto
constant
all day
auto
off
off
Press
buꢀon of corresponding chan-
nel to acꢁvate this mode.
Press again
the end.
buꢀon to disable it before
HOLIDAY
Holiday: Holiday mode allows to switch off
the heaꢁng (or Z1) and hot water (or Z2) for a
specified number of days, adjustable between 1
and 99 days.
constant
all day
auto
constant
all day
auto
off
off
8- Repeat the previous step to program
9- When finished, move the program
On/Off period for HW/Z2.
slider to
posiꢁon to confirm.
To set the holiday funcꢁon:
1- Press Day buꢀon for 5 seconds.
2- OFF appears on the display. Press
or to increment or decrement the
number of days.
OPERATING
MODE SELECTION AND DESCRIPTION
Mode sliders sequences for CH/Z1 and HW/Z2:
Constant
all day
auto
off
Constant: Permanent ON mode. The
system is permanently turned ON.
All day: The system turn ON from the
first On period start ꢁme unꢁl the last Off
period end ꢁme of the current day.
5 sec.
3- Then press
to confirm. the
4- To cancel the holiday funcꢁon, press
heaꢁng (or Z1) and hot water (or Z2)
switch Off and the number of remai-
ning days will count down on display.
buꢀon.
Auto: Automaꢁc mode. The unit is
controlling to the programming that have
been selected (refer to "Programming"
secꢁon page 2).
Off: Permanent Off mode. The system
stays Off permanently. The boost mode
can be sꢁll used.
REVIEW
Review: Review mode allows to review all
programming in one ꢁme. The review starts
from the beginning of the week and each
steps appears each 2 seconds.
BOOST
BOOST: Boost mode is a temporary mode
which allows you to switch ON for 1, 2 or 3
hours. At the end of set period the device
will revert to its prior seꢂng.
Press
review.
buꢀon to start the programming
constant
all day
auto
constant
all day
auto
Press again to go back on normal operaꢁng
off
off
mode.
TEMPERATURE SETTING
The desired temperature can be set.
BOOST will work from any running mode.
1- To set the temperature, turn the dial clo-
BOOST is entered by pressing
Z2).
Press 1 ꢁme to set 1 hour, 2 ꢁmes to set 2 hours and 3 ꢁmes to set 3 hours.
buꢀon for corresponding system (CH/Z1 or HW/
ckwise, to increment the temperature, turn
the dial counter-clockwise, to decrement the
temperature.
The default temperature is 20°C (68°F).
BOOST is cancelled by pressing again on Boost or movement of sliders.
When BOOST is running the end of Boost period is shown for each system.
Note:
- The Programming slider must be in the
- There will be a slight delay between pressing
posiꢁon.
and acꢁvaꢁon of the relay.
3
| General | Details |
|---|---|
| Name | NEOMITIS PRG7 RF 7 Day Two Channel Programmer with RF Room Thermostat Instruction Manual |
| Make | NEOMITIS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.63 MB |

NEOMITIS RTE7OTA Wired Digital 7 Day Programmable Smart Room Thermostat Instruction Manual

Neomitis RTMA Mechanical Room Thermostat Instruction Manual

NEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual

NEOMITIS Rtaneoa Wired Analog Room Thermostat Instruction Manual

NEOMITIS RTE7SD Mains Powered Digital 7 Day Programmable Room Thermostat Instruction Manual

NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual

NEOMITIS RTE0B Wired Digital Room Thermostat Installation Guide

NEOMITIS RTUa Mechanical Room Thermostat Instruction Manual