NEOMITIS PRG7 RF 7 Day Two Channel Programmer with RF Room Thermostat Instruction Manual

FACTORY SETTINGS  
TROUBLESHOOTING  
• Programmer  
Display disappears on programmer:  
Check fused spur supply.  
-
Check that the thermostat is calling for heat if  
-
yes then the thermostat would appear to be  
working check that the boiler has not switched  
itself off. If no increase set temperature.  
Check the posiꢁon of the baꢀeries. Remove  
them for 30 seconds and reinsert them. If the  
problem persists, replace the 2 baꢀeries.  
S
e
n
g
s
Factory seꢁngs  
Heaꢀng does not come on:  
Two On/Off periods seꢂngs  
Start at 06:30 am  
-
If the CH Indicator light is on then it is unlikely  
to be a fault with the programmer.  
If CH indicator light is NOT ON then check pro-  
gramme then try BOOST as this should ope-  
rate in any posiꢁon.  
Period 1  
Period 2  
End at 08:30 am  
End at 10:00 pm  
-
Start at 05:00 pm  
-
Three On/Off periods seꢂngs  
Start at 06:30 am  
Period 1  
Period 2  
Period 3  
End at 08:30 am  
End at 02:00 pm  
End at 10:00 pm  
Nothing in the display:  
-
Check the posiꢁon of the baꢀeries. Remove  
them for 30 seconds and reinsert them. If the  
problem persists, replace the 2 baꢀeries.  
Start at 12:00 pm  
Start at 05:00 pm  
-
Check that your room thermostat is calling for  
heat.  
Check that the boiler is on.  
-
-
-
Check that your pump is working.  
Check that your motorised valve if fiꢀed has  
opened.  
The room temperature is not high enough, the  
boiler is not providing enough heat:  
Note: To restore factory set-  
ꢁngs, press and hold down this  
part for more than 3 seconds  
using the ꢁp of a pen.  
-
Check the acꢁve desired temperature and in-  
3 sec.  
Hot water does not come on:  
crease it if need be (see page 3).  
-
If the HW Indicator light is on then it is unlikely  
to be a fault with the programmer.  
If HW indicator light is NOT ON then check  
programme then try BOOST as this should  
operate in any posiꢁon.  
Check that your Cylinder thermostat is calling  
for heat.  
Check that the boiler is on.  
You made a mistake while seꢁng:  
All LCD display will be turned ON for 2 seconds and the factory seꢂngs will be restored.  
-
You just need to restore factory seꢂngs, as ex-  
plained in the “Factory seꢂngs” secꢁon (see  
page 4). This will reverse any changes you mi-  
ght have made.  
-
• Thermostat  
Seꢁngs  
Factory seꢁngs  
-
The system is not heaꢀng but is on:  
Set temperature  
20°C  
-
If and indicator light is on but the system remains  
cold, then you should contact your installer.  
-
-
-
Note: To restore factory seꢂngs, press and hold down this part for more than 3  
seconds using the ꢁp of a pen.  
Check that your pump is working.  
Check that your motorised valve if fiꢀed has  
opened.  
If the problem persists contact your installer.  
Note: If Service due soon or service due appears  
in display please contact your landlord.  
All LCD display will be turned ON for 2 seconds and  
the factory seꢂngs will be restored.  
The boiler is not heaꢀng:  
TECHNICAL SPECIFICATIONS  
SET DATE AND CLOCK  
Please refer to the installing instrucꢁons for any informaꢁons about standards and product envi-  
1- Move the Programming slider to posiꢁon  
.
ronment.  
Preset year is solid.  
NOTE  
2- To select the current year, press , to  
increment the year.  
3- The preset month appears.  
Press to increment the month.  
Press to decrement the month.  
In some instances the unit may have been set with a message on the screen to remind you that a  
the service interval funcꢁon enabled.  
By Law in rented accommodaꢁon, your gas boi- The Service Due Soon countdown will be indi-  
boiler service is due.  
Press , to decrement the year.  
ler should be inspected/serviced annually to en- cated up to 50 days before the Service is due to  
sure it is working correctly.  
allow ꢁme to arrange for an engineer to aꢀend,  
This opꢁon is designed to remind the end user to normal funcꢁons will conꢁnue during this stage.  
contact the relevant person to have the annual At the end of this service due soon period, the  
service carried out on the boiler.  
unit will go to Service Due OFF at which point  
This funcꢁon will be enabled and programmed only the 1hour boost will operate on TMR7 and  
by your Installer, maintenance Engineer, or Lan- PRG7, if the unit is a thermostat RT1/RT7, it will  
dlord.  
operate at 20°C during this hour.  
If it has been set to do so, the unit will display If PRG7 RF, Thermostat has no funcꢁon.  
WHAT IS A PROGRAMMER ?  
Press  
the current month.  
to confirm and set  
Press  
the current day.  
to confirm and set  
ꢁmes. Set the ‘On’ and ‘Off’ ꢁme periods to suit  
your own lifestyle. On some programmers you  
must also set whether you want the heaꢁng  
and hot water to run conꢁnuously, run under  
the chosen ‘On’ and ‘Off’ heaꢁng periods, or be  
permanently off. The ꢁme on the programmer  
must be correct. Some types have to be adjusted  
in spring and autumn at the changes between  
Greenwich Mean Time and Briꢁsh Summer  
Time. You may be able to temporarily adjust the  
heaꢁng programme, for example, ‘Advance’, or  
‘Boost. These are explained in the manufactu-  
rer’s instrucꢁons. The heaꢁng will not work if  
the room thermostat has switched the heaꢁng  
off. And, if you have a hot-water cylinder, the  
water heaꢁng will not work if the cylinder ther-  
mostat detects that the hot water has reached  
the correct temperature.  
4- The preset day appears.  
Press to increment the day.  
Press to decrement the day.  
5- The preset ꢁme appears.  
Press to increment the ꢁme.  
Press to decrement the ꢁme.  
...an Explanaꢁon for Householders. Program-  
mers allow you to set ‘On’ and ‘Off’ ꢁme pe-  
riods. Some models switch the central heaꢁng  
and domesꢁc hot water on and off at the same  
ꢁme, while others allow the domesꢁc hot water  
and heaꢁng to come on and go off at different  
Move the program  
slider to any  
other posiꢁon to  
confirm/finish this  
seꢂng.  
Press  
the clock.  
to confirm and set  
WHAT IS PID  
The PID feature works by using a formula to calculate the difference between the desired tempera-  
ture setpoint and current ambient temperature, the PID feature then predicts how much power to  
use to ensure the ambient temperature remains as close to the temperature setpoint as possible by  
eliminaꢁng the impact of environmental temperature changes.  
01= January ; 02 = February  
; 03 = March ; 04 = April ; 05  
= May ; 06 = June ; 07 = July  
; 08 = August ; 09 = September ; 10 = Oc-  
tober ; 11 = November ; 12 = December  
NEOMITIS® LIMITED - 16 Great Queen Street, Covent Garden, London, WC2B 5AH UNITED KINGDOM  
Registered in England and Wales No: 9543404  
Tel: +44 (0) 2071 250 236 - Fax: +44 (0) 2071 250 267 - E-mail: contactuk@neomiꢁs.com  
4
GeneralDetails
NameNEOMITIS PRG7 RF 7 Day Two Channel Programmer with RF Room Thermostat Instruction Manual
MakeNEOMITIS
LanguageEnglish
FiletypePDF (Download)
File size2.63 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
NEOMITIS RTE7OTA Wired Digital 7 Day Programmable Smart Room Thermostat Instruction Manual
NEOMITIS RTE7OTA Wired Digital 7 Day Programmable Smart Room Thermostat Instruction Manual
Neomitis RTMA Mechanical Room Thermostat Instruction Manual
Neomitis RTMA Mechanical Room Thermostat Instruction Manual
NEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual
NEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual
NEOMITIS Rtaneoa Wired Analog Room Thermostat Instruction Manual
NEOMITIS Rtaneoa Wired Analog Room Thermostat Instruction Manual
NEOMITIS RTE7SD Mains Powered Digital 7 Day Programmable Room Thermostat Instruction Manual
NEOMITIS RTE7SD Mains Powered Digital 7 Day Programmable Room Thermostat Instruction Manual
NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual
NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual
NEOMITIS RTE0B Wired Digital Room Thermostat Installation Guide
NEOMITIS RTE0B Wired Digital Room Thermostat Installation Guide
NEOMITIS RTUa Mechanical Room Thermostat Instruction Manual
NEOMITIS RTUa Mechanical Room Thermostat Instruction Manual

NEOMITIS PRG7 RF 7 Day Two Channel Programmer with RF Room Thermostat Instruction Manual