Home > NEOMITIS > NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual

NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual

INSTALLATION - RECEIVER  
For best performance, do not mount the receiver on metal wall boxes and leave at  
least 30 cm distance from any metal objects including wall boxes and boiler housing.  
RTE0RFA  
INSTALLATION  
MOUNTING OF WALL MOUTING PLATE  
The receiver is fixed on the wall with the standard wall plate which is supplied with the  
product.  
INSTRUCTIONS  
1- Unscrew the 2 screws under the  
2- Remove the wall plate from the  
receiver.  
receiver.  
WIRELESS DIGITAL ROOM  
THERMOSTAT AND RECEIVER  
x2  
3- Secure the wall plate with the two  
screws provided using the horizontal  
and verꢁcal holes.  
4- In case of surface mounꢁng, a knock  
out area is provided on the wall plate  
and on the corresponding area of the  
receiver.  
TABLE OF CONTENTS  
WIRING  
All electrical installaꢀon work should be carried out by a suitably qualified  
Electrician or other competent person. If you are not sure how to install  
this thermostat consult either with a qualified electrician or heaꢀng  
Engineer. Do not remove or refit the receiver onto the backplate without  
the mains supply to the system being isolated.  
Pack contains........................................................................................................... 1  
Installaꢀon - Receiver.............................................................................................. 1  
Mounꢀng of wall mouꢀng plate................................................................................................. 1  
Wiring......................................................................................................................................... 1  
Mounꢀng of the receiver ............................................................................................................ 1  
All wiring must be in accordance with IEE regulaꢀons. This product is for fixed wiring  
only.  
Installaꢀon - Thermostat ......................................................................................... 2  
Installing baꢁeries...................................................................................................................... 2  
Mounꢀng of thermostat............................................................................................................. 2  
230V Connecꢀons  
Voltage Free Connecꢀons  
Standard wallplate  
supplied with the  
receiver  
Standard wallplate  
supplied with the  
receiver  
Pairing procedure.................................................................................................... 2  
Operaꢀng states of the system................................................................................................... 3  
Troubleshooꢀng ...................................................................................................... 3  
Technical specificaꢀons ........................................................................................... 3  
N
L
1
2
3
4
N
L
1
2
3
4
PACK CONTAINS  
Power supply  
230V~ 50Hz  
Power out  
230V~ 50Hz  
230V Connecꢁon  
In out  
In / out : Voltage  
Free Connecꢁons  
N
L
= Neutral  
= Live  
N
L
= Neutral  
= Live  
1
2
3
4
= Not used  
= Not normally used  
= Common - Power In 230V  
= Call for heat - Power out 230V  
1
2
3
= Not used  
= Not normally used  
= Common - Power In: Voltage Free Connec-  
ꢁons  
= Call for heat - Power Out: Voltage Free  
Connecꢁons  
4
NOTE: The unit is double in insulated so does not require and earth but a terminal is  
supplied for the spare wire.  
x1  
x1  
Receiver  
x1  
Thermostat  
Thermostat table stand  
MOUNTING OF THE RECEIVER  
1- Replace the receiver on the wall  
2- Secure the receiver by screwing the  
mounꢁng plate.  
both locking screws under the receiver.  
x2  
x2  
x4  
x4  
Screws  
AA Baꢀeries (LR6)  
Screw Anchor  
1
RTE0RFA NEO ENG DH V08 18 08 2020  
GeneralDetails
NameNEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual
MakeNEOMITIS
LanguageEnglish
FiletypePDF (Download)
File size1.58 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
NEOMITIS RTE7OTA Wired Digital 7 Day Programmable Smart Room Thermostat Instruction Manual
NEOMITIS RTE7OTA Wired Digital 7 Day Programmable Smart Room Thermostat Instruction Manual
Neomitis RTMA Mechanical Room Thermostat Instruction Manual
Neomitis RTMA Mechanical Room Thermostat Instruction Manual
NEOMITIS Rtaneoa Wired Analog Room Thermostat Instruction Manual
NEOMITIS Rtaneoa Wired Analog Room Thermostat Instruction Manual
NEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual
NEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual
NEOMITIS PRG7 RF 7 Day Two Channel Programmer with RF Room Thermostat Instruction Manual
NEOMITIS PRG7 RF 7 Day Two Channel Programmer with RF Room Thermostat Instruction Manual
NEOMITIS RTE7SD Mains Powered Digital 7 Day Programmable Room Thermostat Instruction Manual
NEOMITIS RTE7SD Mains Powered Digital 7 Day Programmable Room Thermostat Instruction Manual
NEOMITIS RTE0B Wired Digital Room Thermostat Installation Guide
NEOMITIS RTE0B Wired Digital Room Thermostat Installation Guide
NEOMITIS RTUa Mechanical Room Thermostat Instruction Manual
NEOMITIS RTUa Mechanical Room Thermostat Instruction Manual

NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual
Get the free PDF manual for the NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual Overview

Summary of Contents

  • Page 1: Installation instructions for the receiver emphasize avoiding mounting on metal surfaces and maintaining a distance from metal objects. The receiver is fixed to the wall using a standard wall plate included with the product. All electrical installation work should be performed by a qualified electrician or competent person. Do not remove or re-fit the receiver without isolating the mains supply. Wiring must comply with IEE regulations, and the product is intended for fixed wiring only. The pack contains a power supply, receiver, thermostat, and necessary mounting hardware. The unit is double insulated and does not require an earth connection, though a terminal is provided for a spare wire. Instructions for mounting the receiver include securing it with locking screws. The document outlines various connection types, including 230V and voltage-free connections. Additional sections include pairing procedure, operating states, troubleshooting, and technical specifications.
  • Page 2: Secure the thermostat by screwing the locking screws under the thermostat. To ensure accurate readings, install the thermostat approximately 1.5 m above floor level on an inside wall, away from direct sunshine and sources of heat or cold. Ensure that the thermostat is not positioned near areas affected by interference from other sources like wireless transmitters or receivers. The thermostat measures the temperature of the place where it is installed and does not account for temperature differences in different locations in the house. To install batteries, remove the batteries cover, insert 2 AA batteries, and replace the cover, noting the correct polarity. Tilt the thermostat according to its placement in the room; two tilts are available: 30° and 37°. To bond the transmitter and receiver, press and hold the RF test button on the receiver for 5 seconds until the green light blinks. Within 1 minute, press and hold the RF test button on the thermostat for 5 seconds until the pairing icon flashes. Secure the wall plate with the screws provided using the horizontal and vertical holes. Replace the thermostat on the wall mounting plate.
  • Page 3: Thermostat RF icon and receiver Green light will be solid when pairing is complete. Technical specifications include power supply and battery life. Manual temperature setting range is from +5°C to +30°C. Receiver power supply is 230V~50/60Hz with relay outputs of 5(2)A. Maximum range in the home is typically 15m, varying by construction. Signal sending occurs every 10 minutes with a maximum time-lag of 1 minute after set-point temperature change. Operating states of the system include various indicator light colors for connection status. Troubleshooting tips include checking batteries and ensuring proper placement of the thermostat. Radio transmission issues may require resiting the transmitter or receiver to avoid interference. The product must be disposed of at a special recycling point in accordance with European Directive WEEE 2012/19/EU.
  • Page 4: LCD display shows measured room temperature and call for heat icon. To start, insert the two AA batteries provided into the battery compartment. After 2 seconds, the LCD will display the ambient temperature and setpoint temperature. The low battery level indicator appears when batteries must be changed. Remember to take used batteries to collection points for recycling. The thermostat and receiver are not bonded together at the factory. To bond the transmitter and receiver, press and hold the RF test button on the receiver for 5 seconds. Press and hold the RF test button on the thermostat within 1 minute to initiate pairing. The RF icon and receiver green light will blink during pairing and become solid when complete. Thank you for purchasing the wireless digital room thermostat designed for ease of operation and installation.
  • Page 5: OPERATING TROUBLESHOOTING Check that the thermostat is calling for heat if yes then the thermostat would appear to be working check that the boiler has not switched itself off. The desired temperature can be set. To set the temperature, turn the dial clockwise to increment the temperature, turn the dial counter-clockwise to decrement the temperature. The default temperature is 20°C (68°F). Check the active desired temperature and increase it if need be. You must need to restore factory settings, as explained in the “Factory settings” section. If an indicator light is on but the system remains cold, then you should contact your installer. A room thermostat simply switches the heating system on and off as necessary. Turning a room thermostat to a higher setting will not make the room heat up any faster. Room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture.