Home > NEOMITIS > NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual

NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual

3- Thermostat RF icon and receiver  
4- Thermostat RF icon and receiver  
green light will be solid when pairing  
is complete.  
TECHNICAL SPECIFICATIONS  
green light are blinking.  
Power supply: 2 alkaline 1.5 V AA (LR6) baꢀeries.  
Manual temperature seꢂng range: from +5°C to +30°C.  
Baꢀery life: approx. 2 years.  
Receiver:  
- Power supply: 230V~50/60Hz.  
- Relay outputs: 5(2)A.  
- Rated impulse voltage: 4000V.  
- Micro-disconnecꢁon: Type 1B.  
- Polluꢁon degree: 2.  
Override  
RF Test  
Override  
RF Test  
- Automaꢁc acꢁon: 100,000 cycles.  
- Class II.  
Maximum range in the home: 15m is typical but this varies depending on the building  
construcꢁon eg plasterboard lined with metal foil the number of walls and ceilings that  
the signal has to pass through and by the surrounding electromagneꢁc environment.  
Note: the receiver is usually located near your  
boiler.  
Signal sending: every 10 minutes, maximum ꢁme-lag  
1
minute aſter set-point  
temperature has been changed.  
If you want to check the signal strength, press and  
release the RF test buꢀon. The RF icon blink and  
the signal strength appears. 10 is the best signal  
strength.  
Environment :  
- Operaꢁon temperature: 0°C to +40°C.  
- Storage temperature: from -10°C to +60°C.  
- Humidity: 80% at +25°C (without condensaꢁon)  
- Protecꢁon raꢁng: IP30.  
N.B.: this room thermostat is one part of a complete radio system and will only work  
with the 230V AC receiver. Radio emiꢀer, frequency from 2.40 to 2.48 GHz.  
Manufactured by: Neomiꢁs Ltd (contactuk@neomiꢁs.com)  
OPERATING STATES OF THE SYSTEM  
EU declaraꢁon of conformity: We hereby declare under our sole respon-  
sibility that the products described in these instrucꢁons comply with the  
provisions of Direcꢁves and harmonized standards listed below :  
Thermostat  
States of the indicator light Operaꢀng states of the thermostat  
Green  
Receiver is connected to the thermostat  
Orange  
System is calling for heat  
- RED 2014/53/EU:  
RF Signal has been lost, no connecꢁon between thermostat and  
receiver. In order to re-bond the thermostat and receiver refer  
to the installaꢁon instrucꢁons (page 2).  
Arꢁcle 3.1a (Safety): EN60730-1/ EN60730-2-9/ EN62311  
Arꢁcle 3.1b (EMC): ETSI EN 301489-1 / ETSI EN301489-3  
Arꢁcle 3.2 (RF): ETSI EN 300440  
Red  
Direcꢁve RoHS 2011/65/EU, amended by Direcꢁves 2015/863/EU and 2017/2102/EU :  
ROHS: EN50581:2012  
Receiver  
- RED 2014/53/EU:  
Arꢁcle 3.1a (Safety): EN60730-1/EN60730-2-9 / EN62311  
Arꢁcle 3.1b (EMC): ETSI EN301489-1/ ETSI EN301489-3  
Arꢁcle 3.2 (RF): ETSI EN 300440  
TROUBLESHOOTING  
Direcꢁve RoHS 2011/65/EU, amended by Direcꢁves 2015/863/EU and 2017/2102/EU :  
ROHS: EN50581:2012  
and are manufactured using processes that are cerꢁfied ISO 9001 : 2015  
Display disappears on thermostat.  
- Check baꢀeries.  
- Replace the 2 baꢀeries. Only use alkaline 1.5V AA (LR6) baꢀeries.  
Do not use rechargeable baꢁeries.  
Control class and energy contribuꢀon, according to ERP 2009/125/EC and related  
regulaꢀons  
The heaꢀng does not come on or does not go off.  
Class I - On/off Room Thermostat.  
- Your room thermostat may have been set up close to a source of heat or on a cold  
wall – put it in a recommended locaꢁon (see the “Installing” secꢁon on page 2 for  
these locaꢁons).  
- Check that the radio communicaꢁon works between the thermostat and the receiver.  
- Check if the boiler controlled by the programmable room thermostat is properly con-  
nected to the receiver.  
A room thermostat that controls the on/off operaꢁon of a heater. Performance param-  
eters, including switching differenꢁal and room temperature control accuracy are deter-  
mined by the thermostat’s mechanical construcꢁon.  
The  
on the product indicates that you must dispose of it at the end of its useful  
Radio transmission is not working properly:  
life at a special recycling point, in accordance with European Direcꢁve WEEE 2012/19/  
EU. If you are replacing it, you can also return it to the retailer from which you buy the  
replacement equipment. Thus, it is not ordinary household waste. Recycling products  
enables us to protect the environment and to use less natural resources.  
1- The receiver is not picking up the code sent by the thermostat.  
- Check and replace thermostat baꢀeries .  
2- The receiver does not recognize transmiꢁer’s code.  
- Pair the room thermostat transmiꢀer with the receiver again See Pairing secꢁon.  
3- The receiver or the transmiꢁer is affected by interference:  
- Re site the transmiꢀer.  
- If possible, re site the receiver away from the source of the interference.  
The radio link between the thermostat and the receiver is lost.  
- Check the baꢀery level status.  
- Check that the radio communicaꢁon works between the thermostat and the receiver.  
If the radio communicaꢁon does not work between the receiver and the thermostat.  
- Repeat the pairing between the thermostat and receiver (refer to the user instruc-  
ꢁons).  
The thermostat does not control properly.  
- Thermostat sensor may be influenced by a source of heat or cold.  
- Check that the radio communicaꢁon works between the thermostat and receiver.  
If the problem persists, contact your installer.  
3
GeneralDetails
NameNEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual
MakeNEOMITIS
LanguageEnglish
FiletypePDF (Download)
File size1.58 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
NEOMITIS RTE7OTA Wired Digital 7 Day Programmable Smart Room Thermostat Instruction Manual
NEOMITIS RTE7OTA Wired Digital 7 Day Programmable Smart Room Thermostat Instruction Manual
Neomitis RTMA Mechanical Room Thermostat Instruction Manual
Neomitis RTMA Mechanical Room Thermostat Instruction Manual
NEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual
NEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual
NEOMITIS Rtaneoa Wired Analog Room Thermostat Instruction Manual
NEOMITIS Rtaneoa Wired Analog Room Thermostat Instruction Manual
NEOMITIS PRG7 RF 7 Day Two Channel Programmer with RF Room Thermostat Instruction Manual
NEOMITIS PRG7 RF 7 Day Two Channel Programmer with RF Room Thermostat Instruction Manual
NEOMITIS RTE7SD Mains Powered Digital 7 Day Programmable Room Thermostat Instruction Manual
NEOMITIS RTE7SD Mains Powered Digital 7 Day Programmable Room Thermostat Instruction Manual
NEOMITIS RTE0B Wired Digital Room Thermostat Installation Guide
NEOMITIS RTE0B Wired Digital Room Thermostat Installation Guide
NEOMITIS RTUa Mechanical Room Thermostat Instruction Manual
NEOMITIS RTUa Mechanical Room Thermostat Instruction Manual

NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual