NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual
OPERATING
TROUBLESHOOTING
TEMPERATURES SETTING
dŚĞꢀďŽŝůĞƌꢀŝƐꢀŶŽƚꢀŚĞĂƟŶŐ͗
- Check that the thermostat is calling for heat if yes then the thermostat would appear
to be working check that the boiler has not switched itself off.
If no increase set temperature.
The desired temperature can be set.
- Check the posiꢁon of the baꢀeries. Remove them for 30 seconds and reinsert them. If
the problem persists, replace the 2 baꢀeries.
To set the temperature, turn the dial
clockwise, to increment the temperature,
turn the dial counter-clockwise, to decre-
ment the temperature.
EŽƚŚŝŶŐꢀŝŶꢀƚŚĞꢀĚŝƐƉůĂLJ͗
- Check the posiꢁon of the baꢀeries. Remove them for 30 seconds and reinsert them. If
the problem persists, replace the 2 baꢀeries.
C
The default temperature is 20°C (68°F).
C
dŚĞꢀƌŽŽŵꢀƚĞŵƉĞƌĂƚƵƌĞꢀŝƐꢀŶŽƚꢀŚŝŐŚꢀĞŶŽƵŐŚ͕ꢀƚŚĞꢀďŽŝůĞƌꢀŝƐꢀŶŽƚꢀƉƌŽǀŝĚŝŶŐꢀĞŶŽƵŐŚꢀŚĞĂƚ͗
- Check the acꢁve desired temperature and increase it if need be (see page 2).
zŽƵꢀŵĂĚĞꢀĂꢀŵŝƐƚĂŬĞꢀǁŚŝůĞꢀƐĞƫŶŐ͗
- You ꢃust need to restore factory seꢂngs, as explained in the “Factory seꢂngs” secꢁon
(see page 2). This will reverse any changes you might have made.
dŚĞꢀƐLJƐƚĞŵꢀŝƐꢀŶŽƚꢀŚĞĂƟŶŐꢀďƵƚꢀ is on:
- If and indicator light is on but the system remains cold, then you should contact
your installer.
/ĨꢀƚŚĞꢀƉƌŽďůĞŵꢀƉĞƌƐŝƐƚƐ͕ꢀƚŚĞŶꢀĐŽŶƚĂĐƚꢀLJŽƵƌꢀŝŶƐƚĂůůĞƌ͘
OPERATING STATES OF THE SYSTEM
^ƚĂƚĞƐꢀŽĨꢀƚŚĞꢀŝŶĚŝĐĂƚŽƌꢀůŝŐŚƚ KƉĞƌĂƟŶŐꢀƐƚĂƚĞƐꢀŽĨꢀƚŚĞꢀƚŚĞƌŵŽƐƚĂƚ
TECHNICAL SPECIFICATIONS
Green
Receiver is connected to the thermostat
System is calling for heat
KƌĂŶŐĞꢀ
RF Signal has been lost, no connecꢁon between thermostat and
receiver. In order to re-bond the thermostat and receiver refer
to the installaꢁon instrucꢁons.
Please refer to the installing instrucꢁons for any informaꢁons about baꢀeries life, stan-
dards and product environment.
Red
WHAT IS A ROOM THERMOSTAT
OVERRIDE
... an explanaꢁon for householders
A room thermostat simply switches the
heaꢁng system on and off as necessary.
It works by sensing the air temperature,
switching on the heaꢁng when the air
You can press the OVERRIDE buꢀon on the receiver
to manually switch ON/OFF if you have a faulty room
unit or transmission signal. This will be operate unꢁl
communicaꢁon is restored .
Override
RF Test
temperature falls below the thermostat
seꢂng, and switching it off once this set
temperature has been reached.
Turning a room thermostat to a higher set-
ꢁng will not make the room heat up any
faster. How quickly the room heats up de-
FACTORY SETTINGS
pends on the design of the heaꢁng system, for example, the size of boiler and radiators.
Neither does the seꢂng affect how quickly the room cools down.
Turning a room thermostat to a lower seꢂng will result in the room being controlled at
a lower temperature, and saves energy.
^
Ğ
ƫ
Ŷ
Ő
Ɛ
&ĂĐƚŽƌLJꢀƐĞƫŶŐƐ
Set temperature
20°C
The heaꢁng system will not work if a ꢁme switch or programmer has switched it off. The
way to set and use your room thermostat is to find the lowest temperature seꢂng that
you are comfortable with, and then leave it alone to do its ꢃob. The best way to do this
is to set the room thermostat to a low temperature – say 18ꢄC – and then turn it up by
one degree each day unꢁl you are comfortable with the temperature. You won’t have
to adꢃust the thermostat further. Any adꢃustment above this seꢂng will waste energy
and cost you more money.
If your heaꢁng system is a boiler with radiators, there will usually be only one room
thermostat to control the whole house. But you can have different temperatures in indi-
vidual rooms by installing thermostaꢁc radiator valves (TRVs) on individual radiators. If
you don’t have TRVs, you should choose a temperature that is reasonable for the whole
house. If you do have TRVs, you can choose a slightly higher seꢂng to make sure that
even the coldest room is comfortable, then prevent any overheaꢁng in other rooms by
adꢃusꢁng the TRVs.
Note: To restore factory seꢂngs, press and hold down this part for more than 3
seconds using the ꢁp of a pen.
All LCD display will be turned ON for 2 seconds and
the factory seꢂngs will be restored.
Room thermostats need a free flow of air to sense the temperature, so they must not
be covered by curtains or blocked by furniture. Nearby electric fires, televisions, wall or
table lamps may prevent the thermostat from working properly.
ꢁƌĞĂƟŶŐꢀŝŶŶŽǀĂƟǀĞꢀƐŽůƵƟŽŶƐꢀĨŽƌꢀĂŵďŝĞŶƚꢀĐŽŵĨŽƌƚꢀ
NEOMITIS® LIMITED - 16 Great Queen Street, Covent Garden, London, WC2B 5AH UNITED KINGDOM
Registered in England and Wales No: 9543404
Tel: +44 (0) 2071 250 236 - Fax: +44 (0) 2071 250 267 - E-mail: contactuk@neomiꢁs.com
2
| General | Details |
|---|---|
| Name | NEOMITIS RTE0RFA Wireless Digital Room Thermostat and Receiver Instruction Manual |
| Make | NEOMITIS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.58 MB |

Neomitis RTMA Mechanical Room Thermostat Instruction Manual

NEOMITIS RTE7OTA Wired Digital 7 Day Programmable Smart Room Thermostat Instruction Manual

NEOMITIS RTE7D, RTE7BD Wired Digital 7 Day Programmable Room Thermostat Instruction Manual

NEOMITIS Rtaneoa Wired Analog Room Thermostat Instruction Manual

NEOMITIS PRG7 RF 7 Day Two Channel Programmer with RF Room Thermostat Instruction Manual

NEOMITIS RTE7SD Mains Powered Digital 7 Day Programmable Room Thermostat Instruction Manual

NEOMITIS RTE0B Wired Digital Room Thermostat Installation Guide

NEOMITIS RTUa Mechanical Room Thermostat Instruction Manual