L - terminal for live lead
Info: Saving load state before power failure
N - terminal for neutral lead
0 - shutoff load
L1 - output terminals of the device (controlling connected light source)
S - terminal for external switch
NC - No Connection
1
2
0x02(2)
1 - turn on load
2 - save load state before power failure
Info: Enable/disable to send the basic report to the Lifeline
when the load state changed
1) With Normal On/Off Switch
0x03(3)
1
1
0 - Disable to send Basic report
1 - Enable to send Basic report
Enable/disable over current or over load protection, report
alarm when the load is over 16A if enabled
1
1
1
0
0x04(4)
0x05(5)
0: disable
1: enable
External switch type
0: push button switch
1: normal on/off switch
Added to and removed from a network through external
switch (when enables this function, triple press the external
switch to be added to or removed from a network)
0 - disable
1 - enable
1
1
0x07(7)
L
N
Note: if this function is enabled, when triple press the
switch rapidly, the device will be set to inclusion or
exclusion mode, then device status will not be reported
(basic report) during this process.
Power change absolute threshold report, report when the
power change value is over the threshold, unit is W
2) With Single Push Button Switch
0: disable absolute threshold report function
0x0A(10)
1
5
1-255: value of the power change absolute threshold, if
power change value is over the threshold value, report the
power change value using METER_REPORT
PUSH
Current change absolute threshold, unit is 0.1A
0: disable absolute threshold function
1
1
0x0B(11)
1-255: value of the current change absolute threshold, if
current change value is over the threshold value, report the
current change value using METER_REPORT
Voltage change absolute threshold, unit is 1V
0: disable absolute threshold function
0x0C(12)
0x0d(13)
1
4
2
1-255: value of the voltage change absolute threshold, if
voltage change value is over the threshold value, report the
voltage change value using METER_REPORT
Time cycle to report the values of energy
consumption, voltage, current and load power
actively
1800(30mins)
L
60-2678400 (31 days), value of the time cycle, unit is S.
N
| General | Details |
|---|---|
| Name | namron Touch Z Wave 16A Thermostat Instruction Manual |
| Make | NAMRON |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.54 MB |

namron 1402746 Touch Thermostat Instruction Manual

namron 4512738 Touch Zigbee 16A Thermostat Instruction Manual

namron 4512737 Touch Zigbee 16A Thermostat Instruction Manual

namron 16A 2.0 Zigbee Touch Thermostat Instruction Manual