Configuration C ommand C las s  
Wiring Diagram  
Notes f or the diagrams :  
Parameter  
Size  
Description  
Default Value  
L - terminal for live lead  
Info: Saving load state before power failure  
N - terminal for neutral lead  
0 shutoff load  
L1 - output terminals of the device (controlling connected light source)  
S - terminal for external switch  
NC - No Connection  
1
2
0x02(2)  
1 turn on load  
2 save load state before power failure  
Info: Enable/disable to send the basic report to the Lifeline  
when the load state changed  
1) With Normal On/Off Switch  
0x03(3)  
1
1
0 Disable to send Basic report  
1 Enable to send Basic report  
Enable/disable over current or over load protection, report  
alarm when the load is over 16A if enabled  
1
1
1
0
0x04(4)  
0x05(5)  
0: disable  
1: enable  
External switch type  
0: push button switch  
1: normal on/off switch  
Added to and removed from a network through external  
switch (when enables this function, triple press the external  
switch to be added to or removed from a network)  
0 - disable  
1 - enable  
1
1
0x07(7)  
L
N
Note: if this function is enabled, when triple press the  
switch rapidly, the device will be set to inclusion or  
exclusion mode, then device status will not be reported  
(basic report) during this process.  
Power change absolute threshold report, report when the  
power change value is over the threshold, unit is W  
2) With Single Push Button Switch  
0: disable absolute threshold report function  
0x0A(10)  
1
5
1-255: value of the power change absolute threshold, if  
power change value is over the threshold value, report the  
power change value using METER_REPORT  
PUSH  
Current change absolute threshold, unit is 0.1A  
0: disable absolute threshold function  
1
1
0x0B(11)  
1-255: value of the current change absolute threshold, if  
current change value is over the threshold value, report the  
current change value using METER_REPORT  
Voltage change absolute threshold, unit is 1V  
0: disable absolute threshold function  
0x0C(12)  
0x0d(13)  
1
4
2
1-255: value of the voltage change absolute threshold, if  
voltage change value is over the threshold value, report the  
voltage change value using METER_REPORT  
Time cycle to report the values of energy  
consumption, voltage, current and load power  
actively  
1800(30mins)  
L
60-2678400 (31 days), value of the time cycle, unit is S.  
N
GeneralDetails
Namenamron Touch Z Wave 16A Thermostat Instruction Manual
MakeNAMRON
LanguageEnglish
FiletypePDF (Download)
File size0.54 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
namron 1402746 Touch Thermostat Instruction Manual
namron 1402746 Touch Thermostat Instruction Manual
namron 4512738 Touch Zigbee 16A Thermostat Instruction Manual
namron 4512738 Touch Zigbee 16A Thermostat Instruction Manual
namron 4512737 Touch Zigbee 16A Thermostat Instruction Manual
namron 4512737 Touch Zigbee 16A Thermostat Instruction Manual
namron 16A 2.0 Zigbee Touch Thermostat Instruction Manual
namron 16A 2.0 Zigbee Touch Thermostat Instruction Manual

namron Touch Z Wave 16A Thermostat Instruction Manual