Micro-Air 359 Touchscreen Thermostat Instruction Manual
Gas Heat Override
Gas Heat Override operation is an algorithm for calling for additional stages of heat when the thermostat
determines more are needed. The two escalating stages are shown in Table 5. This logic is disabled when
both stages are not available.
Staging
Stage 1
Stage 2
Heat Source
Heat Pump/Heat Strip
Gas/Hydronic Heat
Table 5 - Heat Staging
Table 6 shows how Gas Heat Override affects the heat pump and heat strip operational modes when
enabled. This applies to heating cycle calls in auto operational modes as well.
Environment (°F)
Operation
Inside 4° Or Less Below Setpoint Normal Heating Operation (Stage 1)
Inside 5° Or More Below Setpoint Stage 1 and Stage 2 Runs Until Setpoint is Satisfied
Stage 2 Starts and Runs Any Heat Cycle For Next Two Hours
3 Cycles in a Row Call for Escalation
(Stage 1 is “Locked Out” during this time)
Table 6 - Furnace GHO Operation
(Hysteresis) for details.
12
©2023 Micro-Air Corp
July 3, 2023, revision 1.4
| General | Details |
|---|---|
| Name | Micro-Air 359 Touchscreen Thermostat Instruction Manual |
| Make | Micro-Air |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.5 MB |

micro-air EasyTouch 357 Multi Zone Replacement Thermostat Instruction Manual

Micro-Air EasyTouch RV 353 Touch Screen Thermostat Instruction Manual

Micro-Air EasyTouch RV 353 Thermostat Instruction Manual

micro-Air EasyTouch RV 351 Thermostat User Manual

Micro Air ETRV EasyTouch RV Thermostat Instruction Manual

micro-air EasyTouch RV 356 True Air RV Thermostat User Manual

micro-Air ASY-357-X02 EasyTouch 357 Touchscreen Thermostat User Manual

micro-Air EasyTouch 352 Thermostat User Manual

Micro-Air EasyTouch 355 Touch Screen Thermostat User Manual

Micro-Air 351 Air Conditioner Digital Thermostat User Guide