Honeywell ATC928 Evohome Connected Multi Zone Room Thermostat Installation Guide
evohome Installation Guide
45
Two-port zone valve
Figure 7ꢀConnecting a
two port zone valve
G/Y: Green/Yellow Earth wire
BL: Blue Motor Neutral
BR: Brown Motor Live
GR: Grey End switch (if
used) Permanent Live
O: Orange End switch (If
used). In wired system
this typically feeds the
boiler. When a wireless
relay box is fitted the end
switch is not required.
A-B:5(3)A
A-C:5(3)A
BDR91
230V
50-60Hz
N L L A B C
<5A
L
N
G/Y
BL BRGR
M
O
V4043H
!
If connecting a two
port zone valve with
an unvented cylinder
connection for a high
limit thermostat, the
'L' permanent live
feed must be broken
when high limit cutout
activates on the
insertion thermostat.
C
o
n
n
e
c
t
i
n
g
a
n
O
p
e
n
t
h
e
r
m
b
r
i
d
g
e
Figure 8ꢀWiring an
OpenTherm Bridge to
an OpenTherm boiler.
Opentherm bridge
Opentherm equipped boiler
Opentherm input on the boiler ONLY.
Do not connect to the room thermostat
terminals
| General | Details |
|---|---|
| Name | Honeywell ATC928 Evohome Connected Multi Zone Room Thermostat Installation Guide |
| Make | Honeywell |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.53 MB |

Honeywell T6 Pro Programmable Thermostat User Manual

Honeywell D1-528 Direct Thermostat Installation Guide

Honeywell FocusPRO P200 Programmable Thermostat User Guide

Honeywell RCHT8610WF Series Smart Thermostat Installation Guide

Honeywell T9 Smart Thermostat Installation Guide

Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide

Honeywell TL116A Thermostat Installation Guide

T10 Pro Smart Thermostat with Redlink Room Sensor

Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide

Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide