Home > HEATIT > heatit Z-Temp2 Wireless Thermostat Instruction Manual

heatit Z-Temp2 Wireless Thermostat Instruction Manual

PRODUCT INFO  
Heatit Z-Temp2  
USE CASE  
SENSORTYPE  
SIZE  
SCALE  
PRECISION  
Sends tempe- Temperatu-  
2Byte = 0x02  
Celsius (°C)  
= 0x00  
1 decimal  
= 0x01  
rature report  
from internal  
sensor  
re(version 1)  
= 0x01  
FEATURES  
•
•
•
•
•
•
•
•
•
•
•
Z-Wave thermostat for controlling external relays  
Sends relative Relative humi- 2Byte = 0x02  
humidity  
report from  
internal sensor  
Percentage  
value (%)  
=0x00  
1 decimal  
= 0x01  
Internal room sensor  
dity (version 2)  
= 0x05  
Humidity sensor  
Proximity sensor to turn on the display  
SmartStart  
Notification Command Class  
Automatic brightness control  
Firmware updates (OTA)  
When the device is turned back on after a power outage (insearted  
fresh batteries), the device sends a notification command to indicate  
that the device is back in idle state. The Device will also send a humidity  
report and temperature report when powered back on.  
Weekly program/setback via gateway  
5 associations  
Lock mode/child lock  
EVENT  
TYPE  
EVENT  
LENGTH  
Supports encryption modes S0, S2 Authenticated Class,  
S2 Unauthenticated Class  
Power On (OxFF)  
Power maneg-  
ment (0x08)  
Power has been  
applied (0x01)  
0x00  
This product is a security-enabled Z-Wave Plus product with  
encryption. The product must be used with a security-enabled  
Z-Wave Controller in order to fully utilize the product.  
20. SUPPORTED COMMAND CLASSES  
The following table lists all Command Classes supported by the Z-Wave  
Device. The device supports both S0, S2 Authenticated security and S2  
Unauthenticated security.  
TECHNICAL DATA  
Protocol  
Z-Wave  
INSECURE INSECURE  
SECURE  
Chip  
Z-Wave 700 chip  
3 x AA batteries (1,5V)  
C  
INCLUSION ON SECURE ON  
Rated voltage  
INCLUSION  
SECURE  
RH  
COMMAND_CLASS_ZWAVEPLUS_INFO_V
COMMAND_CLASS_ASSOCIATION_V2  
eters  
0°C (default 0,5°C)  
COMMAND_CLASS_MULTI_CHANNEL_  
ASSOCIATION_V2  
COMMAND_CLASS_ASSOCIATION_GRP_  
INFO_V3  
us V2, CE,  
COMMAND_CLASS_TRANSPORT_  
SERVICE_V2  
RED 2014/53/EU, ETSI EN 301 489-1 V2.2.3 (2019-11), ETSI EN 301 489-3  
V2.1.1 (2019-03), ETSI EN 300 220-1 V3.1.1 (2017-02), ETSI EN 300 220-2  
V3.2.1 (2018-06), EN 62479:2010, EN 62368-1:2014+A11:2017, RoHS  
2011/65/EU  
COMMAND_CLASS_VERSION_V3  
Yes  
Yes  
Yes  
Yes  
COMMAND_CLASS_MANUFACTURER_SPE-  
CIFIC_V2  
COMMAND_CLASS_DEVICE_RESET_  
LOCALLY_V1  
Yes  
Yes  
MAINTENANCE  
COMMAND_CLASS_INDICATOR_V3  
COMMAND_CLASS_POWERLEVEL_V1  
COMMAND_CLASS_BATTERY_V1  
COMMAND_CLASS_SECURITY_V1  
COMMAND_CLASS_SECURITY_2_V1  
COMMAND_CLASS_NOTIFICATION_V8  
COMMAND_CLASS_SUPERVISION_V1  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
The device is maintenance-free, but must never be covered.  
ART. NO. PRODUCT  
COLOR  
FREQUENCY  
Yes  
Yes  
45 126 66 Heatit Z-Temp2 thermostat Battery White RAL 9003 EU 868,4MHz  
45 126 67 Heatit Z-Temp2 thermostat Battery Black RAL 9011 EU 868,4MHz  
99 306 10 Heatit Z-Temp2 thermostat Battery White RAL 9003 RU 869,0MHz  
99 306 68 Heatit Z-Temp2 thermostat Battery White RAL 9003 AUS 921,4MHz  
Yes  
Yes  
COMMAND_CLASS_FIRMWARE_  
UPDATE_MD_V5  
Yes  
Yes  
Yes  
Yes  
COMMAND_CLASS_THERMOSTAT_MODE_ Yes  
V3  
COMMAND_CLASS_THERMOSTAT_SETPO-  
INT_V3  
Yes  
COMMAND_CLASS_THERMOSTAT_  
OPERATING_STATE_V1  
Yes  
Heatit Controls AB can not be held liable for  
typographical errors, other errors or omittances in  
our information. Product specifications may change  
without further notice.  
COMMAND_CLASS_PROTECTION_V1  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
COMMAND_CLASS_CONFIGURATION_V4  
All electrical installations must be carried out by a  
licensed electrician. The product must be installed  
in accordance with national building codes and our  
installers manual.  
COMMAND_CLASS_SENSOR_  
MULTILEVEL_V5  
COMMAND_CLASS_APPLICATION_  
STATUS_V1  
Yes  
Yes  
Yes  
Heatit Controls AB  
Phone: +47 61 18 77 77  
l
Läkarvägen 4, 454 31 BRASTAD, SWEDEN  
post@heatit.com – www.heatit.com  
l
GeneralDetails
Nameheatit Z-Temp2 Wireless Thermostat Instruction Manual
MakeHEATIT
LanguageEnglish
FiletypePDF (Download)
File size0.22 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual
heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual
HEATIT Z-TRM3 Thermostat User Guide
HEATIT Z-TRM3 Thermostat User Guide
Heatit Z-TEMP2 Thermostat Installation Guide
Heatit Z-TEMP2 Thermostat Installation Guide
heatit Z-TRM3 WiFi Thermostat Instruction Manual
heatit Z-TRM3 WiFi Thermostat Instruction Manual
HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual
HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual
4512673 Heatit ZM Thermostat 16A User Guide
4512673 Heatit ZM Thermostat 16A User Guide
HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide
HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide
HEATIT 54 304 59 DIN Smart Thermostat Installation Guide
HEATIT 54 304 59 DIN Smart Thermostat Installation Guide
HEATIT 54 305 41 WiFi6 Thermostat Installation Guide
HEATIT 54 305 41 WiFi6 Thermostat Installation Guide
HEATIT Z-TEMP3 Thermostat User Guide
HEATIT Z-TEMP3 Thermostat User Guide

heatit Z-Temp2 Wireless Thermostat Instruction Manual