heatit Z-Temp2 Wireless Thermostat Instruction Manual
11. CHILD LOCK - LOC
17. ASSOCIATIONS
By pressing Left and Right (down and up buttons for 10 seconds,
the thermostat will display LOC. Child lock is now activated, and the lock
icon will be lit up when the display is active. Trying to make changes from
the display is not possible within this modus. Changes with the Z-Wave
controller is still possible. Refer to your primary controller/gateways user
manual on how to change the setpoint.
Z-Wave devices interact with other Z-Wave devices. The relationship
between one device controlling another device is called an association.
In order to control a subordinate device, the controlling device needs to
maintain a list of devices that will receive controlling commands. These
lists are called ”Association Groups”. They are always related to the specific
event triggered (e.g., sensor reports). In case the event is triggered, all
devices stored in the respective association group will receive a joint
wireless command.
Child lock is deactivated by pressing Left and Right (down and up)
buttons for 10 seconds, the thermostat will display oPn. The lock symbol
is no longer lit when the display is active, and now you can make changes
using buttons.
SETTING AND REMOVING ASSOCIATIONS
Associations may be assigned and removed via Z-Wave commands.
Please refer to your primary controller/Z-Wave gateway for more
information.
12. INVERTED OUTPUT
The thermostat can invert its signal sent to external relays. This allows
users to use the Heatit Z-TEMP2 together with other systems. You can
change this behaviour using a quick feature in the thermostat or, using
Parameter 15“Inverted Output”.
ASSOCIATION GROUPS
ROOT DEVICE
THE MAIN THERMOSTAT DEVICE
Group 1
Lifeline
Lifeline. (Normally used by the Z-Wave
Controller) Sends:
Changing the behaviour,
- Battery Report (sent when battery runs low).
- Notification Report (sent first time power on).
- Device Reset Locally Notification (sent if device
is reset).
- Indicator Report
- Thermostat Mode Report (sent when mode
changed from panel).
- Thermostat Setpoint Report (sent when
setpoint changed from panel).
- Thermostat Operating State Report (sent when
heating should be active).
ting - when external relay is turned ON,
tandard Output
•
•
From physical device by holding centre and right button for 10 sec.
From gateway by changing parameter 15 (for more information
regarding the configuration parameter, see chapter“Configuration
Parameters”).
The thermostat will display“HEA”for regular operation, and“COO”for
inverted operation. You can check wh
centre button for 10 seconds.
ling - when external relay is turned ON,
nverted Output.
r Multilevel Report (periodical reports).
ction Report (childlock activated/
ved from panel).
13. STANDBY AND MAIN SCREEN
When the thermostat remains untouc
automatically go to standby screen. D
in standby, the display will be turned
the thermostat when proximity is sensed. You can also activate the
thermostat manually by pressing any button.
odes in group: 5
vel Sensor Report (internal measured
ate and measured relative humidity).
Max. nodes in group: 5
Binary Switch Set (normally used to control
external relays).
Sends:
0x00 = OFF
0xFF = ON
Max. nodes in group: 5
14. Z-WAVE QR-CODE / DSK
The QR Code is needed when including using S2-Security or
SmartStart. The Z-Wave DSK can be found in the QR-Code and is
located;
18. CONFIGURATION PARAMETERS
1. On the back of wall mount (above the battery compartment).
2. Inside the packaging attached on the note.
3. On the product packaging.
Z-Wave products are supposed to work out of the box after inclusion.
Some configuration of a device can alter the functionality to better serve
the user’s needs or unlock further enhanced features.
15. SECURITY
Parameter 1, Parameter Size 2. Temperature/ Humidity report interval
Used to adjust the time between report interval for Temperature and humidity reports.
The S2 security enhances Z-Wave Plus with an additional layer of AES 128-
bit encryption of the wireless Z-Wave communication to prevent hacking
and man-in-middle attacks on the home network. The Heatit Z-Temp2
supports S2 and has a Z-Wave DSK QR-Code label that may be used when
the module is added to the Z-Wave home network. The primary controller
will ask for a 5-digit Code, which can be found underneath the QR-Code.
The primary controller will then ask you to confirm the rest of the code
that is contained in the QR-Code.
VALUE
READ- ADVANCED ALTERING
DESCRIPTION
ONLY
CAPABILITIES
30 to 32 767
0
0
0
30 to 32 767 seconds
(Default 900)
Parameter 2, Parameter Size 2. Temperature delta value
VALUE
READ- ADVANCED ALTERING
DESCRIPTION
ONLY
CAPABILITIES
0
Reporting tempe-
rature based on
change is disabled
16. NODE INFORMATION FRAME
0
0
0
The node information frame is the business card of a Z-Wave device.
It contains information about the device type and its technical features.
The add and remove procedure of the device is confirmed by sending
out a node information frame. Besides this, it may be necessary for certain
network operations to send out a node information frame.
5 to 50
0.5 to 5°C
(Default 10, 1.0°C)
| General | Details |
|---|---|
| Name | heatit Z-Temp2 Wireless Thermostat Instruction Manual |
| Make | HEATIT |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.22 MB |

heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual

HEATIT Z-TRM3 Thermostat User Guide

Heatit Z-TEMP2 Thermostat Installation Guide

heatit Z-TRM3 WiFi Thermostat Instruction Manual

HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual

4512673 Heatit ZM Thermostat 16A User Guide

HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide

HEATIT 54 304 59 DIN Smart Thermostat Installation Guide

HEATIT 54 305 41 WiFi6 Thermostat Installation Guide

HEATIT Z-TEMP3 Thermostat User Guide