Home > HEATIT > Heatit Z-TEMP2 Thermostat Installation Guide

Heatit Z-TEMP2 Thermostat Installation Guide

SETTING AND REMOVING ASSOCIATIONS  
Associations may be assigned and removed via Z-Wave commands.  
Please refer to your primary controller/Z-Wave gateway for more  
information.  
10. HYSTERESIS (DIF)  
You can make changes to the hysteresis in the thermostat via the  
parameter. This means that you can changes the hysteresis from  
0,3°C up to max 3,0°C. Default is 0,5°C.  
ASSOCIATION GROUPS  
11. CHILD LOCK - LOC  
By pressing Left and Right (down and up buttons for 10 seconds,  
the thermostat will display LOC. Child lock is now activated, and the  
lock icon will be lit up when the display is active. Trying to make  
changes from the display is not possible within this modus. Changes  
with the Z-Wave controller is still possible. Refer to your primary  
controller/gateways user manual on how to change the setpoint.  
ROOT DEVICE  
THE MAIN THERMOSTAT DEVICE  
Group 1  
Lifeline  
Lifeline. (Normally used by the Z-Wave  
Controller) Sends:  
- Battery Report (sent when battery runs low).  
- Notification Report (sent first time power on).  
- Device Reset Locally Notification (sent if device  
is reset).  
- Indicator Report  
- Thermostat Mode Report (sent when mode  
changed from panel).  
- Thermostat Setpoint Report (sent when  
setpoint changed from panel).  
- Thermostat Operating State Report (sent when  
heating should be active).  
Child lock is deactivated by pressing Left and Right (down and up)  
buttons for 10 seconds, the thermostat will display oPn. The lock  
symbol is no longer lit when the display is active, and now you can  
make changes using buttons.  
- Sensor Multilevel Report (periodical reports).  
- Protection Report (childlock activated/  
deactived from panel).  
Max. nodes in group: 5  
12. STANDBY AND MAIN SCREEN  
Group 2  
Temperature Report  
Multilevel Sensor Report (internal measured  
temperate and measured relative humidity).  
Max. nodes in group: 5  
When the thermostat remains untouched for a while, it will  
automatically go to standby screen. Due to power saving settings,  
while in standby, the display will be turned off. The proximity sensor  
will activate the thermostat when proximity is sensed. You can also  
activate the thermostat manually by pressing any button.  
Group 3  
ON/OFF Control  
Binary Switch Set (normally used to control  
external relays).  
Sends:  
0x00 = OFF  
0xFF = ON  
Max. nodes in group: 5  
13. Z-WAVE QR-CODE / DSK  
The QR Code is needed when including using S2-Security or  
SmartStart. The Z-Wave DSK can be found in the QR-Code and is  
located;  
17. CONFIGURATION PARAMETERS  
Z-Wave products are supposed to work out of the box after inclusion.  
Some configuration of a device can alter the functionality to better  
serve the user’s needs or unlock further enhanced features.  
1. On the back of wall mount (above the battery compartment).  
2. Inside the packaging attached on the note.  
3. On the product packaging.  
Parameter 1, Parameter Size 2. Temperature/ Humidity report interval  
Used to adjust the time between report interval for Temperature and humidity reports.  
14. SECURITY  
VALUE  
READ- ADVANCED ALTERING  
DESCRIPTION  
The S2 security enhances Z-Wave Plus with an additional layer of AES  
128-bit encryption of the wireless Z-Wave communication to prevent  
hacking and man-in-middle attacks on the home network. The Heatit  
Z-Temp2 supports S2 and has a Z-Wave DSK QR-Code label that may  
be used when the module is added to the Z-Wave home network.  
The primary controller will ask for a 5-digit Code, which can be found  
underneath the QR-Code. The primary controller will then ask you to  
confirm the rest of the code that is contained in the QR-Code.  
ONLY  
CAPABILITIES  
30 to 32 767  
0
0
0
30 to 32 767 seconds  
(Default 900)  
Parameter 2, Parameter Size 2. Temperature delta value  
VALUE  
READ- ADVANCED ALTERING  
DESCRIPTION  
ONLY  
CAPABILITIES  
0
Reporting tempe-  
rature based on  
change is disabled  
0
0
0
5 to 50  
0.5 to 5°C  
(Default 10, 1.0°C)  
15. NODE INFORMATION FRAME  
The node information frame is the business card of a Z-Wave device.  
It contains information about the device type and its technical  
features. The add and remove procedure of the device is confirmed  
by sending out a node information frame. Besides this, it may  
be necessary for certain network operations to send out a node  
information frame.  
Parameter 3, Parameter Size 2. Humidity delta value  
VALUE  
READ- ADVANCED ALTERING  
DESCRIPTION  
ONLY  
CAPABILITIES  
0
Reporting tempe-  
rature based on  
change is disabled  
0
0
0
5 to 50  
5 to 50%  
(Default 10, 10%)  
16. ASSOCIATIONS  
Z-Wave devices interact with other Z-Wave devices. The relationship  
between one device controlling another device is called an  
association. In order to control a subordinate device, the controlling  
device needs to maintain a list of devices that will receive controlling  
commands. These lists are called ”Association Groups. They are always  
related to the specific event triggered (e.g., sensor reports). In case  
the event is triggered, all devices stored in the respective association  
group will receive a joint wireless command.  
Parameter 4, Parameter Size 2. Temperature offset settings  
Calibrate the internal sensor. NB! To set negative values; 65 535 – desired value + 1.  
VALUE  
READ- ADVANCED ALTERING  
DESCRIPTION  
ONLY  
CAPABILITIES  
-100 to 100  
0
0
0
-100 to 100°C  
(Default 0, 0°C)  
GeneralDetails
NameHeatit Z-TEMP2 Thermostat Installation Guide
MakeHEATIT
LanguageEnglish
FiletypePDF (Download)
File size0.23 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual
heatit Z-TRM6 DC Z Wave Electronic Thermostat Instruction Manual
HEATIT Z-TRM3 Thermostat User Guide
HEATIT Z-TRM3 Thermostat User Guide
heatit Z-TRM3 WiFi Thermostat Instruction Manual
heatit Z-TRM3 WiFi Thermostat Instruction Manual
HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual
HEATIT Z-Temp3 is a Battery Operated Thermostat Instruction Manual
4512673 Heatit ZM Thermostat 16A User Guide
4512673 Heatit ZM Thermostat 16A User Guide
HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide
HEATIT Z-TRM6 Matt Z-Wave Thermostat User Guide
HEATIT 54 304 59 DIN Smart Thermostat Installation Guide
HEATIT 54 304 59 DIN Smart Thermostat Installation Guide
HEATIT 54 305 41 WiFi6 Thermostat Installation Guide
HEATIT 54 305 41 WiFi6 Thermostat Installation Guide
HEATIT Z-TEMP3 Thermostat User Guide
HEATIT Z-TEMP3 Thermostat User Guide
heatit ET-7AW Touchscreen Programmable Thermostat User Manual
heatit ET-7AW Touchscreen Programmable Thermostat User Manual

Heatit Z-TEMP2 Thermostat Installation Guide