DEVIreg™ Touch
Sensing units
NTC 6.8 kOhm at 25°C
NTC 10 kOhm at 25°C
NTC 12 kOhm at 25°C
NTC 15 kOhm at 25°C (Default)
NTC 33 kOhm at 25°C
NTC 47 kOhm at 25°C
Sensing values:
(Default NTC 15 K)
0°C
20°C
50°C
42 kOhm
18 kOhm
6 kOhm
Control
PWM (Pulse Wide Modulation)
0° to +30°C
Ambient temperature
Frost protection
temperature
5°C to +9°C (default 5°C)
Temperature range
Room temperature: 5-35°C.
Floor temperature: 5-45°C.
Max. floor: 20-35°C
(if unrecoverable seal is broken
then up to 45°C).
Min. floor: 10-35°C, only with
combination of room and floor
sensor.