DEVI 532 Electronic Thermostat Installation Guide
DEVIreg™ 532
3
Settings
How to change the minimum and maximum ꢁoor
temperatures
1.
2.
Remove the adjustment button.
e v i r e g 5
3
2
4
5
Move the pins to the desired
positions.
6
40
30
50
20
3.
Put the adjustment button back
in place.
Note: Please be aware of the following:
•
•
•
The ꢀoor temperature is measured where the ꢀoor
sensor is placed.
The temperature of the bottom of a wooden ꢀoor can
be up to 10 degrees higher than the top.
Floor manufactures often specify the max
temperature on the top surface of the ꢀoor (usually
27-28 ˚C).
•
•
By default, the maximum ꢀoor temperature is set to
35 °C.
Always use a ꢀoor sensor or a room + ꢀoor sensor
combination to control ꢀoor heating. Without a ꢀoor
sensor, the temperature control may be less accurate
and you risk overheating the ꢀoor.
10
Installation Guide
| General | Details |
|---|---|
| Name | DEVI 532 Electronic Thermostat Installation Guide |
| Make | DEVI |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.19 MB |

DEVI 140F1143 Electronic Intelligent Timer Thermostat Installation Guide

DEVIreg Electronic Intelligent Timer Thermostat Installation Guide

DEVI 330 Electronic Thermostat Installation Guide

DEVI 140F1161 Intelligent Electronic Timer Controlled Thermostat Installation Guide

DEVIreg 130 Electronic Thermostat Installation Guide

DEVI 140F1064 Touch Electronic Intelligent Timer Thermostat Installation Guide

DEVIreg 316 Electronic Thermostat Installation Guide

DEVI 530M Electronic Thermostat Installation Guide

DEVI 610 Electronic Thermostat Installation Guide

DEVI 316 Electronic Thermostat Installation Guide