WHITE-RODGERS 1F91-71 Multi Stage Electronic Digital Thermostat Installation Guide
After heating and cooling system have been checked and
are running properly, determine if automatic changeover
is desired (see SYSTEM CONFIGURATION).
CHECK THERMOSTAT OPERATION
FAN OPERATION
Refer to the OPERATION GUIDE if you need additional
information on thermostat operation.
1. Turn on power to the system. If the heat source has
a standing pilot, be sure to light it.
FAN
SWITCH
2. Press
until FAN is displayed. The blower
TROUBLESHOOTING
should begin to operate.
Refer to the Question & Answer section of the OPERA-
TION GUIDE for information on troubleshooting the ther-
mostat.
FAN
SWITCH
3. Press
until FAN is displayed. The blower
should stop operating within approximately one
minute.
HEATING SYSTEM
NOTE
When checking thermostat, option switch #4 (for auto-
matic changeover) must be in the OFF position, to allow
temporary setting of heat setpoints above cool settings.
After system checkout, reset option switch #4 to the ON
position if automatic changeover is desired (see SYS-
TEM CONFIGURATION).
LOCKOUT BYPASS OPTION
SYSTEM
SWITCH
CAUTION
!
1. Press
until HEAT is displayed (it may al-
ready be displayed).
2. Press
to adjust thermostat to 99°F. All stages
FOR QUALIFIED SERVICE TECHNICIANS’ USE
ONLY. OPERATORS SHOULD NOT USE THIS
FEATURE DUE TO POSSIBILITY OF EQUIPMENT
ORPROPERTYDAMAGE,ORPERSONALINJURY.
of the heating system should begin to operate within
fiveminutes(ifthecompressorisnotoperating,itmay
be locked out. See LOCKOUT BYPASS OPTION).
DO NOT USE THE LOCKOUT BYPASS OPTION
UNLESSTHECOMPRESSOROILHEATERSHAVE
BEEN OPERATIONAL FOR 6 HOURS AND THE
SYSTEM HAS NOT BEEN OPERATIONAL FOR AT
LEAST 5 MINUTES.
COOLING SYSTEM
CAUTION
!
Topreventcompressorand/orpropertydamage,
if power to the compressor has been off or
interrupted for more than 1 hour and the outdoor
temperature is below 50°F, DO NOT operate the
system for at least the amount of time the com-
pressor was off! This will allow the compressor
heaters to warm the compressor oils to avoid
damage due to slugging.
COMPRESSOR SHORT TERM CYCLE
PROTECTION
This thermostat has a built-in short term (5-minute)
time delay. During this 5-minute period, the thermo-
stat will lock out the compressor to allow head pres-
sure to stabilize. If you want to override this feature
ADV
while testing thermostat operation, simply press
PRGM
SYSTEM
SWITCH
1. Press
2. Press
until COOL is displayed.
HOLD
and
buttons at the same time at initial startup.
TEMP
to adjust the thermostat to 40°F. All
stages of the cooling system should come on within
fiveminutes(ifthecompressorisnotoperating,itmay
be locked out. See LOCKOUT BYPASS OPTION).
7
| General | Details |
|---|---|
| Name | WHITE-RODGERS 1F91-71 Multi Stage Electronic Digital Thermostat Installation Guide |
| Make | WHITE RODGERS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.11 MB |

White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual

White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual

White-Rodgers 1F56N-444 Thermostat User Manual

White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual

White-Rodgers M30 Thermostat Instruction Manual

WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual

White Rodgers 1F78-151 Non Programmable Thermostat Instructions

WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual

WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual

WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual