TROUBLESHOOTING
CONTINUED FROM FIFTH PAGE
7
Symptom
Possible Cause
Corrective Action
Heat, Cool or Fan Runs
Constantly.
1. Possible short in wiring.
Check each wire connection to verify they are not
shorted or touching together. No bare wire should
stick out from under terminal screws. Try resetting the
thermostat as described above. If the condition persists
the manufacturer of your system or service person
can instruct you on how to test the Heat/Cool system
for correct operation. If the system operates correctly,
replace the thermostat.
2. Possible short in thermostat.
3. Possible short in heat/cool/fan system.
4. FAN Switch set to Fan ON.
Furnace Cycles Too Fast 1. The location of the thermostat and/or
or Too Slow (narrow or
wide temperature swing)
Digital thermostats normally provide precise temperature
control and may cycle faster than some older mechanical
models. A faster cycle rate means the unit turns on
and off more frequently but runs for a shorter time so
there is no increase in energy use. If you would like
to increase the cycle time, clip Jumper W-905 as for
Hydronic Heating Systems. It is not possible to shorten
the cycle time. If an acceptable cycle rate is not achieved
as received or by clipping W-905 contact a local service
person for additional suggestions.
the size of the Heating System may be
influencing the cycle rate.
Cooling Cycles Too Fast 1. The location of the thermostat and the size The cycle rate for cooling is fixed and can not be
or Too Slow (narrow or
wide temperature swing)
of the Cooling System can influence the
cycle rate.
adjusted. Contact a local service person for suggestions.
Thermostat Setting
and Thermostat
Thermometer Disagree
1. Thermostat thermometer setting requires
adjustment.
The thermometer can be adjusted +/- 3 degrees. See
Temperature Display Adjustment in the Operation
section.
Blank Display and/or
Keypad Not Responding
1. Voltage spike or static discharge.
2. Battery change required.
Replace batteries and check heat/cool system for
proper operation. If a voltage spike occurs use the Reset
Operation listed above.
Homeowner Help Line: 1-800-284-2925
White-Rodgers is a division
of Emerson Electric Co.
The Emerson logo is a
trademark and service mark
of Emerson Electric Co.
| General | Details |
|---|---|
| Name | White Rodgers 1F78-144 Non Programmable Thermostat Instruction Manual |
| Make | WHITE RODGERS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.42 MB |

White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual

White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual

White-Rodgers 1F56N-444 Thermostat User Manual

White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual

White-Rodgers M30 Thermostat Instruction Manual

WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual

White Rodgers 1F78-151 Non Programmable Thermostat Instructions

WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual

WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual

WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual