2. Set the ring color.
- Press key for 5 s this starts the configuration for choosing the lightable ring color
within 2 minutes timeout. The “LeD” apperas on the display to indicate the “Ring color”
choice; every press to the “Display Brigtness” button changes the selected ring color.
Press key for 5 s to confirm the “Ring Color”, saving is confirmed by three flashes
• Relay output with voltage-free contact: 5(2) A 240 V~
• Input for external sensor (art. 02965.1-20432-19432-14432) with the following functions: XX
- replacement of the internal sensor
- average with the internal one
- screed temperature limitation
on the Lightable ring.
• Current settable setpoint: 4°C - 40°C.
Note: if you don’t want to save the chosen color, let the 2 min timeout expire.
• Temp. measurement precision (integrated probe): 0.5°C between +15°C and 30°C, 0.8°C at
the extremes
Summary of Zigbee technology mode signalling.
• For use for Heating/Air Conditioning (winter/summer).
• Operating modes: Automatic, Manual, Reduction, Absence, Protection, Off, Timed Manual
• Temperature control algorithms: ON/OFF or configurable PID
• 4 front buttons for control and configuration/reset
• RGB LED for configuration status (flashing blue) and output status (configurable colour) sig-
nalling
Colour of the ring
Flashing white
Display
Meaning
Measured
Active pending Hub association
(for max 5 min.)
Temperature
Flashing blue
bt
bt
Pending receipt of a fw update
(for max 2 min.)
• Operating temperature: T40 (0 °C +40 °C) (indoor use)
• Protection degree: IP30
Device associated via Bluetooth with the
smartphone
Blue pernament
• ErP classification (EU Reg. 811/2013): - ON/OFF: class I, contribution 1%. - PID: class IV,
contribution 2%.
Flashing amber
(for max 2 min.)
H
C
Heating temperature calibration
• Device in class II
• Number of manual cycles: 3,000
Flashing cyan (for max 2min.)
Flashing cyan for three times
Cooling temperature calibration
Save Calibration
• Number of automatic cycles: 100,000
• Type of contact opening: micro-disconnection
• Type of action: 1BU
Fixed current color
(for max 2 min.)
LeD
Ring color setting
Save ring color
• Tracking index: PTI175
• State of pollution: 2
Flashing for three times
• Rated pulse voltage: 4000 V
• Software class: A
Flashing green
quickly 3 times
Device correctly associated with the Smart
Hub
• Reading resolution: 0.1 °C
• Settings resolution: 0.1 °C
• Update of temperature displayed: every 10 s
• Room temperature display: 0 °C +40 °C
• Hysteresis adjustable via App: from 0.1 °C to 1 °C
• Hourly temperature setting (via App)
RESETTING THE THERMOSTAT
The reset restores the factory settings. Within the first 5 minutes of powering, press
for
30 s; during these 30 s the ring flashes blue and then emits 2 white flashes to confirm the
operation.
• Room temperature during transportation: -25 °C +60 °
• Clock error: ≤ 1 s per day
THERMOSTAT DATE/TIME SETTING
• With the View Wireless App, the Installer configures the thermostat and creates climate
control programmes.
In the event of a mains voltage outage, if the thermostat is configured in Stand alone and
the “ON Mode”-“Automatic” is set, the date and time can be inserted directly on the device
without using the App.
• With the View Wireless App and the View App, the Administrator creates or modifies climate
control programmes.
1. Press
; you have entered the “Time entry” phase; during this phase, keys
are not operational.
,
• Controllable via View App, Alexa, Google, Siri and Homekit voice assistantfor
and
2. Turn the ring and display the number representing the desired day of the week (1=Monday,
OPERATION IN Bluetooth technology MODE.
2=Tuesday, 3=Wednesday and so on).
In Bluetooth technology mode, the device should configured using the View Wireless App.
3. Confirm by pressing
; now proceed and set the time.
The App can be used to set the following parameters:
4. Turn the ring and display the number representing the hours (00, 01, 02 and so on all the
• Lighting in standby: high, medium, low, off; default = medium
way to 23).
• Circular ring indication selection: automatic or monochrome; default = automatic
• RGB colour selection: in the event of monochrome, possibility of setting the colour
• Temperature calibration for heating: between -5°C and +5°C with default = 0°C
• Temperature calibration for air conditioning: between -5°C and +5°C with default = 0°C
• External probe use: deactivated, average with the internal one, replacing the internal one;
default = deactivated
5. Confirm by pressing
; now proceed and set the minutes.
6. Turn the ring and display the number representing the minutes (00, 01, 02 and so on all the
way to 59).
7. Confirm by pressing
; the thermostat returns to the state it was in before the blackout
and the display and part 2 of the ring stop flashing.
N.B. During the selection phases, the display and part 2 of the ring flash and key
flashes
• Relay output status: normally open, normally closed; default = normally open
• Control type: On/Off, PID; default = On/Off
red. If no selection is made within 2 minutes, the thermostat quits the procedure.
To change the time without a blackout press
1 to 7 above.
for 5 s and perform the procedure from point
• Hysteresis for On/Off control: between 0.1°C and 1°C; default = 0.2°C
• Proportional band for PID control: between 0.5°C and 5°C; default = 3°C
• Integrative time for PID control: between 5 min and 120 min; default = 20 min
• Derivative time for PID control: between 0 and 255 s, disabled; default = 0
• Cycle time for PID control: between 10 min and 30 min; default = 10 min
INSTALLATION RULES.
• Installation and configuration must be carried out by qualified persons in compliance with
the current regulations regarding the installation of electrical equipment in the country where
the products are installed.
The View Wireless App can also be used to associate a magnetic or wired contact of art.
03980 to turn off the temperature control system in the event of an open window; in this case,
the time for reaction and reactivation of contact opening and closing can be set:
• Reaction time: between 0 minutes (instantaneous) and 30 minutes; default = 0 minutes
• Reactivation time (time after which the thermostat is reactivated even without closing the
window): between 0 (disabled) and 12 hours; default = 1 hour.
• The C-NO contact of the relay must be protected against overloads by installing a device,
fuse or automatic 1-way switch, with a rated current not exceeding 10 A.
• Do not connect a SELV circuit to the C-NO terminals as there is no double insulation on the
L-N terminals
• The device must be installed in a flush mounting box or surface mounting box with the related
mounting frames and cover plates, at a height of 1.5 m above floor level, in a suitable position
for the correct detection of the room temperature, avoiding installation in recesses, behind
doors and curtains, areas affected by heat sources or subject to the flow of forced heating/
cooling ventilation sources or affected by atmospheric factors. Avoid in particular installation
on perimeter walls or in association with devices which generate heat (e.g. dimmers or lamps).
The View App can be used to set:
• Time schedules (times and temperature levels T1, T2 and T3)
• Setpoint for all operating modes (Manual, Reduction, Absence, Protection)
• Manual operation time: between 1 min and 23 hours (with 1-min steps); default = 60 min
• Screed, exclusive Temp. ext, average functions.
OPERATION IN Zigbee technology MODE.
CHARACTERISTICS.
In zigbee technolgy, associate the device directly to a ZigBee Gateway (e.g. Amazon Echo Plus,
• Rated supply voltage: 100-240 V~, 50/60 Hz.
SmartThings Hub). The following parameters could be set:
• Dissipated power: 0.55 W.
• Standby lighting: high, medium, low, off; default = medium
• RF transmission power: < 100mW (20dBm).
• Frequency range: 2400-2483.5 MHz.
• Ring indication selection: automatic or monochrome; default = automatic
• RGB colour selection: in the monochromatic case, the color can be set
• Temperature calibration for heating: from -5°C to +5°C; default = 0°C
• Temperature calibration for cooling: from -5°C to +5°C; default = 0°C
•
T
e
r
m
i
n
a
l
s
:
- 2 terminals (L and N) for line and neutral
- 2 terminals for external temperature probe (art. 02965.1 and 20432-19432-14432)
Maximum length of the external sensor connection cable: 10 m.
Use a twisted cable with a minimum cross-section of 0.5 mm2 (art. 01840).
- 2 C-NO relay terminals.
Viale Vicenza 14
36063 Marostica VI - Italy
30810.x-02973 04 2311
| General | Details |
|---|---|
| Name | VIMAR 30810.x-02973 Smart Home View Wireless Connected Dial Thermostat Instruction Manual |
| Make | VIMAR |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.14 MB |

VIMAR 30810.x-02973 Connected Dial Thermostat Instruction Manual

VIMAR 02912 Wi-Fi Thermostat Instruction Manual

VIMAR 02952 Well-Contact Plus Electronic Touchscreen Thermostat Instruction Manual

VIMAR 02913 Surface LTE Thermostat Installation Guide

VIMAR 01910 Electronic Timer Thermostat Instruction Manual

VIMAR 02971 Smart Automation Rotary Dial Thermostat Instruction Manual

VIMAR 30810.G View Wireless Connected Dial Thermostat Instruction Manual

VIMAR 02970 Wheel Thermostat Instruction Manual