Electrical Ratings  
Table 1.  
277V  
Pole  
Line-M2 (Main)  
Number  
Line-M1 (Auxiliary)  
Motor  
Rating  
120V  
208V  
240V  
120V  
208V  
240V  
277 V  
AC Full Load  
Amps  
16.0  
9.2  
8.0  
6.0  
3.3  
3.0  
AC Locked  
Rotor Amps  
96.0  
16.0  
55.2  
9.2  
48.0  
8.0  
36.0  
6.0  
19.8  
6.0  
18.0  
6.0  
AC Non-Ind  
Amps  
7.2  
6.0  
Pilot Duty-Both Poles  
125 VA, 24 to 600 Vac  
57.5 VA, 120 to 300 Vdc  
Mounting and  
Installation  
General Guidelines  
Locate the sensing element in the downstream side of the coil.  
Locate the case and bellows where the ambient temperature is always warmer than  
the setpoint.  
Install the thermostat so that the reset button is readily accessible and the element  
bellows points down.  
Install as much of the bulb as possible in a horizontal plane. If too much of the bulb  
is vertical, it will not operate properly.  
Avoid sharp bends or kinks in the sensing element.  
Large walk-in Ducts  
(Figure 1)  
1. Attach the mounting bracket to the thermostat with the two round head screws  
provided.  
2. Mount the two perforated steel strap hangers inside the duct with the wide part of  
the hanger strap parallel to the air flow.  
3. Drill a hole in the side of the duct. With the bulb still coiled, thread the bulb through  
the hole using a rotary movement.  
4. Mount the thermostat on the outside of the duct.  
5. Carefully uncoil the bulb avoiding sharp bends or kinks in the sensing element.  
6. Mount the bulb in a horizontal, serpentine manner, attaching the bulb to the strap as  
shown in detail in Figure 1.  
The installation is complete.  
NOTE: For an alternate method of mounting, use coil clips (Part Number 356-115) in  
the fins to hold the bulb in a horizontal, serpentine pattern.  
Siemens Industry, Inc.  
Page 3  
GeneralDetails
NameSIEMENS ET 134-22 Low Temperature Detection Thermostat Instructions
MakeSIEMENS
LanguageEnglish
FiletypePDF (Download)
File size0.1 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
SIEMENS RDZ100ZB Zigbee Room Thermostat Owner’s Manual
SIEMENS RDZ100ZB Zigbee Room Thermostat Owner’s Manual
SIEMENS RDG400 Room Thermostat Instruction Manual
SIEMENS RDG400 Room Thermostat Instruction Manual
SIEMENS M3182 Room Thermostat Instruction Manual
SIEMENS M3182 Room Thermostat Instruction Manual
SIEMENS RDS120-B Smart Thermostat Instructions
SIEMENS RDS120-B Smart Thermostat Instructions
SIEMENS Powers Controls TH 192-3 Series Day Night Vent Room Thermostat Instruction Manual
SIEMENS Powers Controls TH 192-3 Series Day Night Vent Room Thermostat Instruction Manual
SIEMENS RDY2000BN BACnet Commercial Thermostat User Manual
SIEMENS RDY2000BN BACnet Commercial Thermostat User Manual
SIEMENS RDH100RF/SET Room Thermostat Instruction Manual
SIEMENS RDH100RF/SET Room Thermostat Instruction Manual
SIEMENS RDH100RF/SET Wireless Room Thermostat with LCD User Guide
SIEMENS RDH100RF/SET Wireless Room Thermostat with LCD User Guide
SIEMENS RS485 Flush Mounted Room Thermostat User Manual
SIEMENS RS485 Flush Mounted Room Thermostat User Manual
SIEMENS RDG260KN Room Thermostat Instruction Manual
SIEMENS RDG260KN Room Thermostat Instruction Manual

SIEMENS ET 134-22 Low Temperature Detection Thermostat Instructions