Programming Notes
Programming Notes
Custom Programming
Differential Setting
This thermostat can be configured to have 7 Day or 5+1+1 programming. If 7 Day
is selected, all seven days will need to be programmed individually. If 5+1+1
programming is selected, Monday–Friday will be programmed together and
Saturday and Sunday will need to be programmed individually. There are four
time periods for each day (WAKE, LEAVE, RETURN, SLEEP).
The second stage will turn ON at 2x the differential setting and OFF at 1x the
differential setting. For example, if the differential setting is 0.5° for heating
and the thermostat is set at 70°F, the first stage will turn on at 69.5°F. The
second stage will turn on at 69°F and turn off at 69.5°F. If the third stage is
used, the third stage will turn on at 68.5°F and turn off at 69°F.
Follow the steps below to customize your program schedule:
1. Select HEAT or COOL. Note: Heat and cool need to be programmed separately.
2. Press MENU (If menu does not appear first, press RUN SCHED).
Keypad Lockout
The installer can activate a keypad lockout after exiting Tech Setup.
3. Press SET SCHED. Note: Monday–Friday (or Monday if in 7 Day mode) will be
displayed and the WAKE icon is shown.
Contractor Call Number
If contractor call number is selected ON, the selected phone number will show in
the display if there has been a continuous call for heating or cooling for 24 hours or
if the FAN button is held down for 3 seconds. To remove the phone number from
the display, hold the fan button down for 3 seconds.
4. Time will be be flashing. Use
WAKE time period for Monday–Friday (or Monday if in 7 Day mode).
or
to make your time selection for the
5. Press NEXT STEP.
6. The set-point temperature will be flashing. Use
set-point selection for the WAKE time period for Monday–Friday (or Monday
or
to make your
Set Time of day and day of week (If using programming)
if in 7 Day mode).
1. Press the MENU button.
7. Press NEXT STEP.
2. Press SET TIME.
8. Repeat steps 4 through 7 for the LEAVE time period, for the RETURN time
period, and for the SLEEP time period for Monday–Friday (or Monday if in
7 Day mode).
3. Day of the week will be flashing. Use
day of the week.
or
to select the current
4. Press NEXT.
9
Repeat steps 4 through 8 for the Saturday WAKE, LEAVE, RETURN, and SLEEP
time periods, and then again for the Sunday WAKE, LEAVE, RETURN, and
SLEEP time periods for the 5+1+1 program schedule, and for each day for the
7-day program schedule.
5. The current hour will be flashing. Use
Note the correct a.m. or p.m. indicator is selected.
or
to select the current hour.
6. Press NEXT.
7. The minutes will be flashing. Use
or
to select the current minutes.
8. Press DONE when completed.
13
14
Programming Notes
Thermostat Quick Reference
Default Program
This thermostat is pre-programmed for energy saving operation.
The default program is below:
Notes
Auto Changeover: In Auto mode, users can toggle between Auto Heat or
Auto Cool by pressing System only when the current mode has reached its
temperature set point. To switch out of Auto mode, hold down System.
To return to Auto mode, toggle the System key to Auto.
Default Program
Set-Point Set-Point
Temperature Temperature
Day of the
Week
Events
Time
(HEAT)
(COOL)
Programmable Fan: The programmable fan feature will run the fan continuously
during any time period it is programmed to be on. This is the best way to keep
the air circulated and to eliminate hot and cold spots in your building.
Wake
Leave
Return
Sleep
Wake
Leave
Return
Sleep
Wake
Leave
Return
Sleep
6 AM
8 AM
6 PM
10 PM
6 AM
8 AM
6 PM
10 PM
6 AM
8 AM
6 PM
10 PM
70°F (21°C)
75°F(24°C)
62° F (17°C)
70°F (21°C)
62°F (17°C)
70°F (21°C)
62°F (17°C)
70°F (21°C)
62°F (17°C)
70°F (21°C)
62°F (17°C)
70°F (21°C)
62°F (17°C)
83°F(28° C)
75°F(24°C)
78°F(26°C)
75°F(24°C)
83°F(28°C)
75°F(24°C)
78°F(26°C)
75°F(24°C)
83°F(28°C)
75°F(24°C)
78°F(26°C)
Reminders: Once a Reminder has been turned on and set, the elapsed time can
be checked by navigating the Tech Setup step. The time can be reset by pressing
and holding the third button from the left for 3 seconds. Resetting an expired
Reminder can be done by pressing and holding the 3rd button from the left for
3 seconds.
Weekday
Saturday
Sunday
Use Phone
to Scan for
Warranty Info
Year
Limited
6Warranty
Customer Service +1.800.304.6563
Technical Service +1.800.445.8299
352-00307-001 Rev. B
© 2021 Robertshaw Controls Company.
Robertshaw® is a trademark of Robertshaw Controls Company.
15
16
| General | Details |
|---|---|
| Name | Robertshaw RS9320T Programmable Touchscreen Wall Thermostat Instruction Manual |
| Make | Robertshaw |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.84 MB |

Robertshaw RS9220 Programmable Thermostat Installation Guide

Robertshaw RS10420T WIFI Programmable Thermostat User Guide

Robertshaw RS8110 Non Programmable Thermostat Instruction Manual

Robertshaw RS8210 Thermostat Installation Guide

Robertshaw RS8210 Non-Programmable Multi-Stage 2H-1C Wall Thermostat User Manual

Robertshaw RS9220 Digital Programmable Wall Thermostat Instruction Manual

Robertshaw 9602 Programmable Thermostat User Manual

Robertshaw RS9423T Thermostat Installation Guide

Robertshaw RTC500 WIFI Thermostat Instruction Manual

Robertshaw RS1110 Programmable 1 Heat 1 Cool Wall Thermostat Instruction Manual