Installation Location
INSTALLATION MANUAL
Install the thermostat 4 to 5 feet above the floor in an area with good air
circulation and average temperature.
For new installations, mount thermostat on an inside wall, 4-5 feet above the floor.
Do not install the thermostat in the following locations:
RS9320T
IMPORTANT SAFETY
INFORMATION WARNING:
• Behind a Door
Thermostat System Types
• In a Corner
Gas, Oil, or Electric Heat with Air Conditioning
Heat Pumps (without auxiliary or emergency heat
Multi-Stage Systems
• Near Air Vents
)
• Always turn off power at the main
power source by unscrewing fuse or
switching circuit breaker to the off
position before installing, removing,
cleaning, or servicing thermostat.
• In Direct Sunlight
Heat-Only, including for Floor and Wall-Furnace
Cool-Only
• With an Outside Wall Behind the Thermostat
• Near any Heat or Steam Generating Fixtures
• Near any Concealed Pipes or Chimneys
750 Millivolt Heating Systems
• Read all of the information in
this manual before installing or
programming this thermostat.
Power Type
Battery Power
Hardwire (Common Wire)
Installation at these locations will affect thermostat operation.
• This is a 24V AC low voltage
thermostat. Do not install on
voltages higher than 30V AC.
Wallplate Installation
Table of Contents
Page
Installation Location
Mounting & Battery Installation
Thermostat Quick Reference
Wiring
2
3
4
1
2
Horizontal Mount
Vertical Mount
• All wiring must conform to local
and national building and electrical
codes and ordinances.
Caution:
Electrical Hazard
5
Disconnect power before installing this
product. Failure to do so can cause electric
shock or equipment damage.
• Do not short (jumper) across
terminals on the gas valve or at the
system control to test installation.
This will damage the thermostat
and void the warranty.
Wiring Diagrams
6-8
9-12
13-15
16
Installer Setup Menu
Programming Notes
Thermostat Quick Reference
Specifications
Mercury Notice
Temperature Display Range................ 32°F to 99°F (0°C to 40°C)
Temperature Control Range ............... 41°F to 90°F (5°C to 32°C)
Load Rating................................................ 1 amp per terminal, 1.5 amp maximum all
terminals combined
Differential.................................................. Heating is adjustable from 0.2° to 2.0°
Cooling is adjustable from 0.2° to 2.0°
Power Source ............................................ 18 to 30 VAC, NEC Class II, 50/60 Hz for hardwire
Battery power from 2 AAA Alkaline batteries
Operating Ambient Temperature..... 32°F to +105°F (0°C to +41°C)
Operating Humidity............................... 90% non-condensing maximum
Dimensions................................................ 4.7”W x 4.4”H x 1“D
This product is mercury-free. However,
if this product is replacing a control
which contains mercury, it needs to
be disposed of properly. Contact your
local waste management authority for
instructions regarding recycling and
proper disposal of the control.
For a vertical mount, put screws
on the top and bottom.
For a horizontal mount, put screws
on the left and the right.
1
2
Mounting & Battery Installation
Thermostat Quick Reference
Mounting Thermostat
Getting to know your thermostat
Sun Mon Tue Wed Thu Fri Sat
WAKE LEAVE RETURN SLEEP
Align the 4 tabs on the faceplate with the
corresponding slots on the back of the
thermostat, then push gently until the
Sun
Set At
WAKE
Sun Mon Tue Wed Thu Fri Sat
WAKE LEAVE RETURN SLEEP
Set At
Set At
thermostat snaps into place.
SYSTEM
Heat
FAN
Auto
On
IAQ
SYSTEM
HOLD
FAN
Auto
On
IAQ
Heat Off
Cool
Auto
Menu
Em.heat
SYSTEM
HOLD
FAN
Auto
On
IAQ
Heat ON
Cool
Auto
Technician
Setup
Next Step
Set Time
Clean
Next Zone
Set Schedule
Hold
Previous Step
Run Schedule
Menu
Em.heat
Done
Technician
Setup
Set Time
Clean
Set Schedule
Hold
Run Schedule
Menu
Next Step
Next Zone
Previous Step
Done
Battery Installation
Battery installation is optional if used with AC power
(the C terminal is connected). During power outages,
the batteries will save settings and power the display.
1
2
Days of the week and time
Indicates the current room
temperature
3
4
5
Displays the user selectable
set-point temperature
Important:
Fan Buttons
1
2
3
4
5
6
7
5
5
High quality alkaline batteries are recommended.
Rechargeable batteries or low quality batteries are not
recommended.
Hold is displayed when thermostat
program is overridden.
Next Step Buttons
Set Time Buttons
Program Buttons
Menu Buttons
System Operation Indicators:
The compressor delay is active if
these are flashing.
Insert 2 AAA
Alkaline batteries
(included). High
quality alkaline
batteries are
6
7
System Buttons
Set-Point Buttons
Battery Cover
Programmable Time Periods:
Residential uses 4 time periods -
WAKE, RETURN, LEAVE and SLEEP.
recommended.
Program Menu Options:
Shows different options during
programming.
Button/Battery Access Door
Low Battery Indicator: Replace
batteries when this indicator is
shown.
8
3
4
| General | Details |
|---|---|
| Name | Robertshaw RS9320T Programmable Touchscreen Wall Thermostat Instruction Manual |
| Make | Robertshaw |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.84 MB |

Robertshaw RS9220 Programmable Thermostat Installation Guide

Robertshaw RS10420T WIFI Programmable Thermostat User Guide

Robertshaw RS8110 Non Programmable Thermostat Instruction Manual

Robertshaw RS8210 Thermostat Installation Guide

Robertshaw RS8210 Non-Programmable Multi-Stage 2H-1C Wall Thermostat User Manual

Robertshaw RS9220 Digital Programmable Wall Thermostat Instruction Manual

Robertshaw 9602 Programmable Thermostat User Manual

Robertshaw RS9423T Thermostat Installation Guide

Robertshaw RTC500 WIFI Thermostat Instruction Manual

Robertshaw RS1110 Programmable 1 Heat 1 Cool Wall Thermostat Instruction Manual

Robertshaw RS9320T Manual: Questions and Answers
What is the temperature control range for the Robertshaw RS9320T?
41°F to 90°F (5°C to 32°C). Instruction Manual, p. 1
How do I mount the Robertshaw RS9320T to the wall?
Align the 4 tabs on the faceplate with the corresponding slots on the back of the thermostat, then push gently until it snaps into place.
- For a vertical mount, place screws on the top and bottom.
- For a horizontal mount, place screws on the left and the right. Instruction Manual, p. 1
What do the WAKE, LEAVE, RETURN and SLEEP buttons control?
These are the four programmable time periods for residential use. Instruction Manual, p. 1
Can I install the Robertshaw RS9320T in direct sunlight or behind a door?
No. Do not install in direct sunlight, behind a door, in a corner, near air vents, with an outside wall behind it, or near heat sources, steam fixtures, concealed pipes or chimneys. These locations will affect thermostat operation. Instruction Manual, p. 1