Installation Location  
INSTALLATION MANUAL  
Install the thermostat 4 to 5 feet above the floor in an area with good air  
circulation and average temperature.  
For new installations, mount thermostat on an inside wall, 4-5 feet above the floor.  
Do not install the thermostat in the following locations:  
RS9320T  
IMPORTANT SAFETY  
INFORMATION WARNING:  
• Behind a Door  
Thermostat System Types  
• In a Corner  
Gas, Oil, or Electric Heat with Air Conditioning  
Heat Pumps (without auxiliary or emergency heat  
Multi-Stage Systems  
• Near Air Vents  
)
• Always turn off power at the main  
power source by unscrewing fuse or  
switching circuit breaker to the off  
position before installing, removing,  
cleaning, or servicing thermostat.  
• In Direct Sunlight  
Heat-Only, including for Floor and Wall-Furnace  
Cool-Only  
• With an Outside Wall Behind the Thermostat  
• Near any Heat or Steam Generating Fixtures  
• Near any Concealed Pipes or Chimneys  
750 Millivolt Heating Systems  
• Read all of the information in  
this manual before installing or  
programming this thermostat.  
Power Type  
Battery Power  
Hardwire (Common Wire)  
Installation at these locations will affect thermostat operation.  
• This is a 24V AC low voltage  
thermostat. Do not install on  
voltages higher than 30V AC.  
Wallplate Installation  
Table of Contents  
Page  
Installation Location  
Mounting & Battery Installation  
Thermostat Quick Reference  
Wiring  
2
3
4
1
2
Horizontal Mount  
Vertical Mount  
• All wiring must conform to local  
and national building and electrical  
codes and ordinances.  
Caution:  
Electrical Hazard  
5
Disconnect power before installing this  
product. Failure to do so can cause electric  
shock or equipment damage.  
• Do not short (jumper) across  
terminals on the gas valve or at the  
system control to test installation.  
This will damage the thermostat  
and void the warranty.  
Wiring Diagrams  
6-8  
9-12  
13-15  
16  
Installer Setup Menu  
Programming Notes  
Thermostat Quick Reference  
Specifications  
Mercury Notice  
Temperature Display Range................ 32°F to 99°F (0°C to 40°C)  
Temperature Control Range ............... 41°F to 90°F (5°C to 32°C)  
Load Rating................................................ 1 amp per terminal, 1.5 amp maximum all  
terminals combined  
Differential.................................................. Heating is adjustable from 0.2° to 2.0°  
Cooling is adjustable from 0.2° to 2.0°  
Power Source ............................................ 18 to 30 VAC, NEC Class II, 50/60 Hz for hardwire  
Battery power from 2 AAA Alkaline batteries  
Operating Ambient Temperature..... 32°F to +105°F (0°C to +41°C)  
Operating Humidity............................... 90% non-condensing maximum  
Dimensions................................................ 4.7”W x 4.4”H x 1“D  
This product is mercury-free. However,  
if this product is replacing a control  
which contains mercury, it needs to  
be disposed of properly. Contact your  
local waste management authority for  
instructions regarding recycling and  
proper disposal of the control.  
For a vertical mount, put screws  
on the top and bottom.  
For a horizontal mount, put screws  
on the left and the right.  
1
2
Mounting & Battery Installation  
Thermostat Quick Reference  
Mounting Thermostat  
Getting to know your thermostat  
Sun Mon Tue Wed Thu Fri Sat  
WAKE LEAVE RETURN SLEEP  
Align the 4 tabs on the faceplate with the  
corresponding slots on the back of the  
thermostat, then push gently until the  
Sun  
Set At  
WAKE  
Sun Mon Tue Wed Thu Fri Sat  
WAKE LEAVE RETURN SLEEP  
Set At  
Set At  
thermostat snaps into place.  
SYSTEM  
Heat  
FAN  
Auto  
On  
IAQ  
SYSTEM  
HOLD  
FAN  
Auto  
On  
IAQ  
Heat Off  
Cool  
Auto  
Menu  
Em.heat  
SYSTEM  
HOLD  
FAN  
Auto  
On  
IAQ  
Heat ON  
Cool  
Auto  
Technician  
Setup  
Next Step  
Set Time  
Clean  
Next Zone  
Set Schedule  
Hold  
Previous Step  
Run Schedule  
Menu  
Em.heat  
Done  
Technician  
Setup  
Set Time  
Clean  
Set Schedule  
Hold  
Run Schedule  
Menu  
Next Step  
Next Zone  
Previous Step  
Done  
Battery Installation  
Battery installation is optional if used with AC power  
(the C terminal is connected). During power outages,  
the batteries will save settings and power the display.  
1
2
Days of the week and time  
Indicates the current room  
temperature  
3
4
5
Displays the user selectable  
set-point temperature  
Important:  
Fan Buttons  
1
2
3
4
5
6
7
5
5
High quality alkaline batteries are recommended.  
Rechargeable batteries or low quality batteries are not  
recommended.  
Hold is displayed when thermostat  
program is overridden.  
Next Step Buttons  
Set Time Buttons  
Program Buttons  
Menu Buttons  
System Operation Indicators:  
The compressor delay is active if  
these are flashing.  
Insert 2 AAA  
Alkaline batteries  
(included). High  
quality alkaline  
batteries are  
6
7
System Buttons  
Set-Point Buttons  
Battery Cover  
Programmable Time Periods:  
Residential uses 4 time periods -  
WAKE, RETURN, LEAVE and SLEEP.  
recommended.  
Program Menu Options:  
Shows different options during  
programming.  
Button/Battery Access Door  
Low Battery Indicator: Replace  
batteries when this indicator is  
shown.  
8
3
4
GeneralDetails
NameRobertshaw RS9320T Programmable Touchscreen Wall Thermostat Instruction Manual
MakeRobertshaw
LanguageEnglish
FiletypePDF (Download)
File size0.84 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Robertshaw RS9220 Programmable Thermostat Installation Guide
Robertshaw RS9220 Programmable Thermostat Installation Guide
Robertshaw RS10420T WIFI Programmable Thermostat User Guide
Robertshaw RS10420T WIFI Programmable Thermostat User Guide
Robertshaw RS8110 Non Programmable Thermostat Instruction Manual
Robertshaw RS8110 Non Programmable Thermostat Instruction Manual
Robertshaw RS8210 Thermostat Installation Guide
Robertshaw RS8210 Thermostat Installation Guide
Robertshaw RS8210 Non-Programmable Multi-Stage 2H-1C Wall Thermostat User Manual
Robertshaw RS8210 Non-Programmable Multi-Stage 2H-1C Wall Thermostat User Manual
Robertshaw RS9220 Digital Programmable Wall Thermostat Instruction Manual
Robertshaw RS9220 Digital Programmable Wall Thermostat Instruction Manual
Robertshaw 9602 Programmable Thermostat User Manual
Robertshaw 9602 Programmable Thermostat User Manual
Robertshaw RS9423T Thermostat Installation Guide
Robertshaw RS9423T Thermostat Installation Guide
Robertshaw RTC500 WIFI Thermostat Instruction Manual
Robertshaw RTC500 WIFI Thermostat Instruction Manual
Robertshaw RS1110 Programmable 1 Heat 1 Cool Wall Thermostat Instruction Manual
Robertshaw RS1110 Programmable 1 Heat 1 Cool Wall Thermostat Instruction Manual

Robertshaw RS9320T Programmable Touchscreen Wall Thermostat Instruction Manual
Get the free PDF manual for the Robertshaw RS9320T Programmable Touchscreen Wall Thermostat Instruction Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Robertshaw RS9320T Manual: Questions and Answers

What is the temperature control range for the Robertshaw RS9320T?

41°F to 90°F (5°C to 32°C). Instruction Manual, p. 1

How do I mount the Robertshaw RS9320T to the wall?

Align the 4 tabs on the faceplate with the corresponding slots on the back of the thermostat, then push gently until it snaps into place.

  1. For a vertical mount, place screws on the top and bottom.
  2. For a horizontal mount, place screws on the left and the right. Instruction Manual, p. 1

What do the WAKE, LEAVE, RETURN and SLEEP buttons control?

These are the four programmable time periods for residential use. Instruction Manual, p. 1

Can I install the Robertshaw RS9320T in direct sunlight or behind a door?

No. Do not install in direct sunlight, behind a door, in a corner, near air vents, with an outside wall behind it, or near heat sources, steam fixtures, concealed pipes or chimneys. These locations will affect thermostat operation. Instruction Manual, p. 1