Configuration  
The Elexant 3500i electronic thermostats can be configured in a number of ways. The communicating, current sensing, and ground fault  
detecting variants can be configured locally by means of a handheld programming device using the Elexant Connect application or from  
a central location using the Touch 1500 or nVent RAYCHEM Supervisor software. For more information about configuring the Elexant  
3500i using these software programs, please refer to the Elexant Connect Operations Manual (EU2191), Touch 1500-EX Operations Manual  
(H58682), or the nVent RAYCHEM Supervisor Operations Manual (H57576). After programming, all settings are permanently stored in the  
nonvolatile memory of the Elexant 3500i, avoiding loss of data in the event of power failure or after a long-term power shutdown.  
The Standard and Alarm variants of the Elexant 3500i can be programmed via the digital switches and rotary dial located here:  
Starting from the left, the first dipswitch is to set temperature sensor failure behavior. In the case of sensor failure the Elexant 3500i can  
switch to an on or an off state, depending upon the users requirement. Setting the dipswitch up towards the filled circle will program the  
Elexant 3500i to fail on, while setting the dipswitch down towards the empty circle will program the Elexant 3500i to fail off. By default, the  
Elexant 3500i is shipped with a fail off setting, meaning in the event of a sensor failure, the Elexant 3500i will not energize the heat trace  
circuit. Setting the dipswitch up towards the filled circle will program the Elexant 3500i to energize the heat trace circuit in the event of a  
sensor failure.  
Note that the Standard and Alarm variant of the Elexant 3500i will display a sensor failure alarm via a red status LED and the Alarm variant  
will engage the alarm relay in the event of a sensor failure.  
The second dipswitch is used to switch between Celsius and Fahrenheit. By default, the Elexant 3500i is shipped with this dipswitch down  
towards the Celsius.  
Finally the rotary dials are used to select a setpoint temperature. The Elexant 3500i monitors the sensor temperature and compares it to the  
setpoint temperature. If the measured temperature is above the control temperature setpoint by more than the Deadband value, (by default  
3°C / 5°F) the output is turned off. If the control temperature falls below the control temperature setpoint, the output is turned on. When the  
control sensor temperature is within the dead band, the output does not change its state.  
nVent.com/RAYCHEM  
|
9
GeneralDetails
NamenVent RAYCHEM Elexant 3500i Electronic Thermostat Installation Guide
MakenVent RAYCHEM
LanguageEnglish
FiletypePDF (Download)
File size0.26 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
nVent RAYCHEM ETS-05 Electronic Thermostat Instruction Manual
nVent RAYCHEM ETS-05 Electronic Thermostat Instruction Manual
nVent RAYCHEM RAYSTAT-EX-02 Mechanical Thermostat Installation Guide
nVent RAYCHEM RAYSTAT-EX-02 Mechanical Thermostat Installation Guide
nVent RAYCHEM RayStat-M2 Thermostat Instruction Manual
nVent RAYCHEM RayStat-M2 Thermostat Instruction Manual
nVent RAYCHEM Green Leaf Programmable Thermostat Instruction Manual
nVent RAYCHEM Green Leaf Programmable Thermostat Instruction Manual
nVent RAYCHEM AT-TS-13 Surface Sensing Thermostat Instruction Manual
nVent RAYCHEM AT-TS-13 Surface Sensing Thermostat Instruction Manual
nVent RAYCHEM SENZ Wifi Programmable Floor Heating Thermostat User Guide
nVent RAYCHEM SENZ Wifi Programmable Floor Heating Thermostat User Guide
nVent RAYCHEM GM-TA Thermostat Instruction Manual
nVent RAYCHEM GM-TA Thermostat Instruction Manual

nVent RAYCHEM Elexant 3500i Electronic Thermostat Installation Guide