nVent RAYCHEM Elexant 3500i Electronic Thermostat Installation Guide

INSTALLATION  
For installation/operation, always observe the Equipment Safety Law, the rules of generally accepted engineering practice (IEC 60079-14 /  
EN 60079-14), and the instructions stated in this installation manual. Carry out work on the thermostats in the de-energized state only.  
ꢀBranch circuit protection and disconnection devices shall be provided a location that is easily reached, and identified as the disconnect  
device for the equipment in.  
Mechanical installation  
Elexant 3500i units comprise of either a temperature controller or a safety temperature limiter that can be set via programming. The  
controllers can be installed in any position on a stable structure by means of the 4 mounting holes. The Elexant 3500i unit can be mounted  
directly on a pipe up to a pipe temperature of 205°C (401°F). Ensure that the ambient temperature of the equipment does not exceed 60°C  
(140°F) at any time. To provide sufficient stability, the pipe stand shall be attached by means of 2 pipe straps.  
Connecting cables and Conduit hubs to Elexant 3500i units  
ꢀAt ambient temperatures above 45°C (113°F) the cable selected should have a temperature rating of 90°C (194°F) or higher. Conduit  
hubs with a temperature rating of 90°C (194°F) or higher and Type 4X should be selected.  
ꢀCopper (Cu) conductors shall be used  
Installation instructions for Conduit hubs (threaded holes only.) RTD, communications, and alarm relay wiring must be wired through separate  
conduit hub from high voltage power wiring.  
A
Figure 2: Mounting positions Elexant 3500i  
Enclosure Material Limitations  
Only use approved conduit hubs, suitably certified for the intended area of use.  
Better than 3,2 µm is recommended.  
Maximum level of surface roughness allowed is Ra 6 µm  
Maximum surface roughness of the enclosure wall  
If the sealing surfaces are uneven, use PTFE washer  
NFWM25 or the green fiber washer GFWM25  
(Washers are to be ordered separately)  
Enclosure interface sealing method  
Thickness range for the enclosure wall (t)  
Perpendicularity  
≥ 4 mm (5/32")  
+/–1° or 0,2 mm at the outer edge of the conduit hub, whichever is smaller  
For metal conduit hubs use an internal locknut to assure earth continuity with  
the Elexant 3500i internal earth plate. Alternatively, earth tags connected to one  
of the internal PE terminals can be used.  
Permitted use and location of any earth tags  
For chamfered holes  
Lock nuts  
Only parallel threads are allowed.  
Only use nVent RAYCHEM locknuts or types recommended by the conduit hub  
manufacturer.  
The installation instructions provided by the conduit hub manufacturers must be  
followed.  
Recommended torque values  
6
|
nVent.com/RAYCHEM  
GeneralDetails
NamenVent RAYCHEM Elexant 3500i Electronic Thermostat Installation Guide
MakenVent RAYCHEM
LanguageEnglish
FiletypePDF (Download)
File size0.26 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
nVent RAYCHEM ETS-05 Electronic Thermostat Instruction Manual
nVent RAYCHEM ETS-05 Electronic Thermostat Instruction Manual
nVent RAYCHEM RAYSTAT-EX-02 Mechanical Thermostat Installation Guide
nVent RAYCHEM RAYSTAT-EX-02 Mechanical Thermostat Installation Guide
nVent RAYCHEM RayStat-M2 Thermostat Instruction Manual
nVent RAYCHEM RayStat-M2 Thermostat Instruction Manual
nVent RAYCHEM Green Leaf Programmable Thermostat Instruction Manual
nVent RAYCHEM Green Leaf Programmable Thermostat Instruction Manual
nVent RAYCHEM AT-TS-13 Surface Sensing Thermostat Instruction Manual
nVent RAYCHEM AT-TS-13 Surface Sensing Thermostat Instruction Manual
nVent RAYCHEM SENZ Wifi Programmable Floor Heating Thermostat User Guide
nVent RAYCHEM SENZ Wifi Programmable Floor Heating Thermostat User Guide
nVent RAYCHEM GM-TA Thermostat Instruction Manual
nVent RAYCHEM GM-TA Thermostat Instruction Manual

nVent RAYCHEM Elexant 3500i Electronic Thermostat Installation Guide