CAUTION
When powering the RDT-5, the L1, L2, and L3 ports must be fed from
different power sources, phases, or breakers.
LARM
5.2.5 A
IRING
W
Figure 10: Alarm Port Wiring
An alarm is triggered when:
either the primary or secondary power source fails
•
•
•
a sensor is shorted or fails to operate
the CPU fails
Note that even if the CPU ceases to operate, the RDT-5 continues to function. The CPU
does not run the unit; it is used only to enter the unit parameters.
LATINUM
IRING
– RDT-5 W
5.2.6 P
The RDT-5 can be wired directly to the Platinum’s digital input card. In this configuration,
RDT-5 can provide two functions:
The Platinum transmits an alarm to a PC in the event of a RDT-5 power or sensor
failure. In this configuration the RDT-5 functions when the Platinum has a
problem with its:
•
o
o
o
relays
breakers
sensors
The Platinum transmits an alarm when RDT-5 activates one of the stages
While both of these functions are optional, Munters strongly recommends
wiring the RDT-5 to Platinum Controllers.
•
CAUTION
© Munters AB, 2021